HomeMy WebLinkAboutEngineer's OWTS Designai c SITE EVALUATION SOIL EVALUATION 1. SITE AND SOIL EVALUATIONS WERE PERFORMED BY: SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER KUMAR &ASSOCIAIFS, INC. (KUMAR & ASSOCIATES, INC. (PROJECT NO, 24-7-269.02, LUSH VALVE AT THE END ATTN: DAWD YOUNG, PE AUGUST 1, 2025) AS USDA CLAY, TYPE 4 AND AN LTAR iF EACH LATERAL, TYP. 5020 COUNIYROAD 154 OF 0.20 GPD/SF. p GLENWOOD SPRINGS, CO 81601 - 970.945.7988 y r 2. EVALUATION DATE(S): JULY 2025. �AJ�f FG:6515.50 e / & SETBACK REQUIREMENTS. FOR A TREATMENT LEVEL 1 STA TRENCH/BED, /✓• //,�++ UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF< SURFACE k/ INSPORTf GA.1000 SPRING, WELL OR POTABLE CISTERN=100' PEC NAT EACH CORNER / 3.8. POTABLE WATER SUPPLY LINE=25' SPACE 2 STRUCTURE W BASEMENT/CRAWL j0F EACH BED /TVP. 3.0 / 3.D. STRUCTURE W/O BASEMENT/CRAWL SPACE=10' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' /� (GRAVELLY, VERY STIFF, 3INTERMITTENT IRRIGA LATERALT INFILTRATION ATION STRUCTURE-25/ .SLIGHTLY MOIST, BROWN, 3G LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' STRONG BLOCKY OR FILL AREA=25' 3.1. DRY GULCH, CUT BANK / STRUCTURE) SEPTIC TANK=S' / ! 3.1. SE / SDILTYPE 4 (D,20.GPD/SF) 3.J. RESTRICTIVE LAYER DR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3.. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): ? S.A. SPRING WELL OR POTABLE CISTERN=50 3.B. POTABLE WATER SUPPLY LINE 10 RE IDENCE ( INSTA TWO-WAY , J -° CLEANOUT OUTSIDE THE AUTOMATIC o�, ��,, / / s' j 3.C. STRUCTURE W/BA3EMENT/CRAWL SPACE=5' ---" o BUILDING (SEE DETAIL) //DISTRIBUTING VALVE -�, �/ // ! / 3.D. STRUCTURE W/0 BASEMENT/CRAWL SPACE=5 ���� (SEE DETAIL). MUST �,n 10, &E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' Q CO SCH.40 C BE AT HIGHER / i / 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' -- N E / / A ON THAN TH ® SEWER 2%. MIN. LEV TI � 3 G LAKE WATER COURSE IRRIGATION DITCH STREAM ORWETLAND 5 INSPECTION PORT AT EACH CORNEA OF EACH BED, TYP. :y FG:6514.5 .. .. . �jdj Ij► l 'rive ON t�OWN a ABSORPTIO BEDS <yF 3.H. DRY GULCH, CUT BANK OR FILL AREA=10' '!jJ/ 6 f /// / Ss IT=S' � / / /� 3.1. STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE P PVC SEWER, „� / / Site E Soils Evaluation �+ - Scale: N.T.S. FG:6519.50 \ J w� INSTALL 1000-GALLON Qp\`IE �o --�"` TWO -COMPARTMENT m j f TANK AND 500-GALLON G:6519.50'---- _F+DOSING TANK( DETAILS) Pump Selection for a Pressurized System -Single Family Residence Project Zanetich / BUI #25019 Parameters NOTES ObmargeassamGv Slza 1,25 inches 300 n_ r -••'® \ /" 6510 �O ` /J Transpon Lengthaetorevalve 50 feat �1. PROPERTY LINES AND WELL ARE Transport PIP class 40 U FG:6574:5D'/- ! BEYOND THE MAPPED AREA AND Transpon Line Sir* 1.26 inches qq pOR BED ��• �_'•-• „_.✓' � /✓ j BEYOND THE MINIMUM SETBACK Dwtniueng Valve Model 6402 MFICM+TORUNIIS (4x11) ECTION PORT THE J REQUIREMENTS FROM THE OWTS Transport Lergm AfterVaKe 140 teat 250 S ARC36 UNITS(-�NL]Of THE TRENCH BACKWASH AND/OR FLUSHING -,� ./ / ,/ COMPONENTS. Transport Pipe Sizes Transport Pipesize t1. 36 AD'INFILTRATION SYSTEM: - BASEELEV'b512,5 �-- �/' . 25 Irknas T06ELEVE 21NFILTRATORQUICK4UNITSOR._--� ! MaxfoldLanoth 9 teat Ll / / (BOTTOM OF BED S ,ems „/' / 2. LOCA710NS OF ALL COMPONENTS MAY (SEE SETBACK Nam) '- 2 ADS ARC3fi UNIT / / / / �/ BE VARIED AS NECESSARY AS LONG AS Manifold IpmC g teat ✓^' '-'---- .�--^- �/ � / / / MBNfOld Rpe Class 40 ✓ �' _� - / ALL MINIMUM DISTANCES AND SLOPES Manifold Rpe Size 1.25 inches 200 Hunter of Laterals par cell 4 m .�••� /� Y'^ -„�„` ® ,.o-- / // // LaOaml usno 44 Not a.. -a.a ®,••- �. ,�- -. ��� // / O / / Lateral Pipe Class 1. O "^ F Js� s••�� /// / %/ lateral R S¢e 1A inches a `-j ^" -"-•-` �- -„s- S / / / �/ / < // // Orifi®Sim. 1k inches Orifins,l Head s rant .2 t50 Residual Head 5 feat E Flow Meter None inches I 'Ad6on'Fdcean tosses 0 feel 12" SO. NYLOPLAST H-20 Calculations 1= SOLID COVER ASSEMBLY REMOVABLE PVC CAP FLUSH WITH SURFACE 24"x24"x6" CONCRETE IN HARDSCAPE ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY.1 INSTALL MARKER IF CAP IS TO 1 rFINISH GRADE BE BURIED. PVC RISER 4"0 PVC TWO-WAY CLEANOUT TEE G FLOW 4"0 SEWER LINE IN LANDSCAPE Two-Wa Cleonout Scale: N.T.S.. GENERAL ABSORPTION AREA NOTES 1, INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ABSORPTION BEDS SHALL NOT EXCEED 12' WIDE BY 100-FEET IN LENGTH, SHALL PARALLEL THE TOPOGRAPHY AND SHALL BE INSTALLED IN A RECTANGULAR PATTERN WHENEVER POSSIBLE. 3, THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO $0 MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 1-1/4"O PRESSURE DOSING PIPE.\ WITH 1/4'0 HOLES DRILLED EVERY b r" 5' 0 C., FACING UP, AND ONE (1)- OF - HOLE FACING DOWN AT THE END \� EACH TRENCH (FOR WEEPING),I- INSTALL A 12" PAVER OR SPLASH /\ _ �\\ STONE BELOW THE DOWN FACING - �/ o HOLE TO PREVENT SOIL EROSION. 7 BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE " AREA TO WITHIN OA'.t. (TYP.). IF NECESSARY TO ACHIEVE THIS SURFACE, IMPORT CONCRETE' SAND TO USE AS LEVELING MATERIAL. REMOVE , ANY ENCOUNTERED BOULDERS AND BACKFILL u WITH LOAMY SAND OR SANDY GRAVELS. DO ,\ m NOT USE COMPACTED MATERIALS. 0 N 0 F U a o, z 4. DRAINAGE $WALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5.. NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. Top View 100 Minimum Flow Ratelax Orifice 1.73 gpm Numberof Orificesper Zane 1B Total Flow Rate par Zona 31.6 gpm Numheroflusarsaper Zone 2 % Flow Differential lsNLast Orifice 4.4 % Transport Vebciry SabreValve 6.6 fps 50 Transpon Velocily After Valve 6.6 fps Frictional Head Losses -- - Loss through D'echaroe 8.9 feet Loss in Transport Before Valve 6.1 feet 00 Losamrough Valve 7.5 feet 5 10 15 20 25 unsin Trarepora/ier Vwve 17.0 feet Net Discharge(gpm) Lose in Manifold 0.3 feet Lass in Laterels 0.6 feet Loss the, h Flowmeter 00 feet STYROFOAM INSULATED FIBERGLASS g 'Ada -on' Frlcden Losses 0..0 feet PumpDato LID WITH STAINLESS STEEL BOLTS PF3006 Nigh Head Elauent Pump AND URETHANE GASKET - Pipe Volumes 30 GPM, i2HP Vol of Transport Line Before Valve 39 gals 115=V 10 e0Rz, 2o0V 3060Hz vol. ofTmmprt LlneAfter Valve 10.9 gas ORENCO2ZONE1-1/2"O Vol of Manifold 0.7 gels DISTRIBUTING VALVE va of Laramie Per Zone 6.8 gale ASSEMBLY (V6402A) Total Vol Before Valve 3.9 .gels 24"0 PVC Total Vol After Valve 18.4 OBIS ENCLOSURE CHECKVALVE(S) lquirements 31.6 gpm 0.5 feet 1-1/2"0 SCH.80 PVC FR01vTPL1 O GRAVEL BASE. Automatic Distributing Valve Scale: N.T.S. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE EXCAVATION. 7. TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 3-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. 8. WHEN MULTIPLE BEDS ARE USED, BEDS SHALL BE SEPARATED BY 6-FEET MIN. OF UNDISTURBED SOILS. 9. SECONDARY" SAND MEDIA REQUIREMENTS (43.11.C.2.d.3): 9.1. EFFECTIVE SIZE: 0.15460 MM 9.2. UNIFORMITY COEFFICIENT: < 1.0 9.3. PERCENT FINES PASSING #200 SIEVE: g 3.0 9.4. A GRADATION OF THE SAND MEDIA USED MUST BE PROVIDED. THE GRADATION MUST BE DATED NO MORE THAN ONE MONTH PRIOR TO THE INSTALLATION DATE. HOWEVER, A GRADATION OF THE ACTUAL MATERIAL PLACED IN THE EXCAVATION IS RECOMMENDED. GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS ARC36 (STANDARD), OR ENGINEER APPROVED EQUAL. - COVER THE CHAMBER UNITS WITH A NON -WOVEN FILTERILANDSCAPE FABRIC TO LIMIT FINE MIGRATION INTO THE CHAMBERS CIRCULAR IRRIGATION -STYLE VALVE BOX & COVER - LID COLOR PURPLE OR GREEN - LABEL "SEWER" STANDARD INSPECTION PORT, TYP. (4"0 PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. COVER WITH 6" OF TOPSOIL AND REVEGETATE EXTEND PIPE.MemoOMOF - - = e = __ _ _ (_ -_ \� PIPE TO REST ON BOTTOM OF O -)(_ -I= _ _ _ ____'4"0SCH.40T AND DRILL (8") 1/2"0 1 _ I -I I-II-II-II-II-�I-I II II \\� HOLES IN THE SEC TIONWITHIN -II-II-II-II-II- -II -II -II-I-I-II-II-II-II _ CHAMBER USEAHOLESAW TOCUT OUTCIRCLEOFF THE a CENTER OF THE UNIT o \ FILL OVER THE CHAMBERS a \ UNCOMPACTED WELL \\� GRADED LOCAL SOILS. t DUE TO THE PRESENCE OF EXTENSIVE BOULDERS, REMOVE 3-FEET OF INSTALL A.i2"Wx24'LSPLASH BLOCK BELOW EACH INLET PIPE ` IN -SITU SOIL FROM BENEATH THE ; PREFABRICATED PIPE SUPPORT .c \ \ '•'. BED AND REPLACE WITH SECONDARY .:_'. OR CHEMICAL RESISTANT ZIP / SAND (SEE NOTES) :.- TIE HANGING SYSTEM (PIPE @ •,,, \\ 6 MIN. ABOVE BASE) Gravelless Pressure Dosed Chamber Scale: N.T.S. -egeno System Curve: - Pump Curve:-•' Pump Optimal Ranger! OperaArg Point Design Polrn ' 500 Gallon Top Seam as 1 CP SOOT * with High Head Pump DESIGN NOTES • Design per performance test pal' ASTM C1227 • Top surface woo 23.4 ft' • f'c O 28 days; concrete = 6,000 PSI Min. Installation: • Tank to be set on 5" min. sand bed or pea gravel • Tank to be bockfllled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones we removed • Excavation should be dewatered and tank filled with water prior to being Put In service fw installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet identified above pipe • Delivered complete with .internal piping • Control Panel to be mounted in sight line of tank • 4` Maximum bury depth ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0' - 0" 3' - D" 1'-0' 4'- 0" 2'-Or 4'- W 3'-W 4'-0' DRY 4' - 0' *Service contracts availadte for maintenance.' Top View Clear Access /30 Section _52._ View Pump: • Lowers TSS and improves effluent quality to field • Complete installation (wiring, panel, mounting and start-up procedures) • Complete warranty Di in 5 tics p T Long x T Wide 5 w inlet Insert n r Dimenslona Net Caaeit P Y Net Wei ht e _ _ Ld _ rank o al I Inlet 56- le Out t 54"or73"I m. L. h Width H t. engt g. 58 5B" 92" 522 gals 1,340 Ibs i, 4,100 Ibs 5,640 Ibs o VALLEY 0 PRECASTS lac. Buena Vista, Colorado Phone: 719-395.8784 Fax: 719395-3727 wel alte: www.valleyprecastcolm Email: Unntdeek&alleyprecastoom .TBnwoodsp Glenwood - MAIMENANO _NOTES ,Glenwood Springs, «,, � County of Garfield, a r, { �- , ,•� 1. TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWLS SYSTEM, THE - State of Colorado OWNER SHALL CONSIDER THE FOLLOWING: , Parcel No: 2185-282-88.033- 1.A. MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE DEFTER YOUR SYSTEM WILL WORK. '^ _ t t 1.8. MINIMIZE SOLIDS GOING DOWN THE DRAIN. j 1.C. ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D. MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. +, 54 „•„•..' " I.E. - USE LINT FILTERS ON LAUNDRY MACHINE DRAINS, N� I.F. KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. T 3, I.G. AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN�� �"'�t110� 1 TOILET PAPER.��\\� qq :-lr f, a±k✓ h• 1,H. 00 NOT USE LYE -BASED DRAIN UNCLOGGER CHEMICALS SUCH AS S IT� , DRAINO, OVEN -OFF, OR OTHER STRONG CLEANING AGENTS. I.I. DO NOT PUT ANY "ROOT DETERRENTS" DOWN THE DRAIN. 0 NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB- CHEMICALSDOWNTHEDRAIN- 1.K. MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. m 2. THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR 04 SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. YICIITII,V Mao 2" DUPONT STYROFOAM BRAND HIGHLOAD 60 XPS INSULATION 1� /1 � J11 lr • r IlROADBASE- line insulation 1 "0 BALL VALVE & TREADED 10"01RRIG. VALVE ASSEMBLY BOX 1-1/4" x V PVC REDUCER 1-1/4"0 PVC ELBOW 1-1/4"0 PVC DISTRIBUTION PIPE Flush Valve Scale: N.T.S. MATERIAL: HIGH -DENSITY POLYETHYLENE WALL THICKNESS: TANK WALL .250" DIVIDER WALL - .1911 I IN -- - HOLE IN PARTITION SYSTEM DESIGN & CONSTRUCTION NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (DvVTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS. AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72 HOURS PRIOR TO THE DESIRED TIME OF BACKFILUNG. 2. DEMAND CALCULATIONS (SEC 43.6 A 2.h)(TABLE 6 1) - 2.A. TWO (2) BEDROOM RESIDENCE USING TREATMENT LEVEL 1 (111). 2.B. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOOS): 23.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOD5lbs/day. 2.13.2. ADWF: 75 glad' (2 BEDROOMS " 2 PERSONS/BEDROOM) = 300 gpd 23.3. BOD, = 0.201bs/day * (2 BEDROOMS * 2 PERSONSBEDROOM) = 0.8016s/day BOD5 mg/L = BOW1,000,000 = 0.80 lbs/day*1,000,000 = 319.74 mg/L ADWF*8.34 300 gpd"8.34 2.6.4 CBOD, = BOD, * 0.85 = 272 mg/L 3. SEPTIC TANK (SEC43.9.B.2.a): 3.A INSTALL 1,000-GALLON TWO(2)-COMPARTMENT TANK (PER TABLE 9-1). 3.B. THE TANK IS NOT SUBJECT TO BUOYANCY. 4. ABSORPTION AREA CALCULATIONS: 4.A. LONG TERM ACCEPTANCE RATE (LIAR) FOR TREATMENT LEVEL 1 (11-7) OF 0.20 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.B. MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 300 = 1,500 S.F. - LTAR 0.20 gpd/S.F. 4.C. SIZE ADJUSTMENT FACTORS. PRESSURE DOSED BED =1.0 (TABLE 10 2); CHAMBERS = 0.7 (TABLE 10 3). 4.D. A,adi = 1500 SF * 1.0 * 0.7 = 1,050 SF 4.E. GRAVELLESS CHAMBER SYSTEM: 4.E.1. INFILTRATOR QUICK4.1 G50 SF/ 12 SF/UNIT = 88 UNITS IN A TWO (2) BED CONFIGURATION (4x 11 UNITS EACH). 4.E.2. ADS ARC36 (STANDARD): 1,050 SF/ 15 SF/UNIT = 70 UNITS. INSTALL 72 UNITS IN ATWO (2) BED CONFIGURATION (4 x 9 UNITS EACH). 5. THIS SYSTEM IS SIZED FOR TYPICAL HOUSEHOLD WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. BACKWASH AND FLUSHING FLOWS SHALL BE DISPOSED OF WITHIN A SEPARATE INFILTRATIVE SYSTEM (SEE BELOW). 6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS GREATER THAN 45' AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. B. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED, 9. INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10. SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. BACKWASH OR HUSHING FLOWS: 1. DEMAND CALCULATIONS I.A. WATER SOFTENER -= 15% OF DAILY USE = 300 gpd * 0.15 = 45 gpd 1.8. REVERSE OSMOSIS (RID) UNDER SINK = 2 opal * 4:1 WASTE * 4 PERSONS = 32 go 1.C. TOTAL= 77 gpd 1.D. GRAVELLESS CHAMBER STORAGE CAPACITY: I.D.L. INFILTRATOR QUICK 4: 43 gallons =. USE 2 CHAMBERS 1.D.2 ADS ARC 36: 59 gallons = USE 2 CHAMBERS 1.E. PERCOLATION CHECK (< 24 HOURS): 1.E.1. CHAMBER STORAGE DEPTH: 121N., PERCOLATION RATE (1): 90 MPI (SOIL TYPE 4) 1.E.2. TIME = (DEPTH * 0 * 1 HOUR = (121N. * 90 MPI) * 1 HOUR = 18 HOURS. 60 MIK 60 MIN SERIAL NUMBER EMBOSSE CAN BE REFERENCED T OF MANUFA )RWESCO, INC. ONIFACRIS, MN JAN CAPACITY I COVER 3.0 FT. OPERATING VOLUME: PRIMARY COMPARTMENT: 662 GALLONS S1ZI PERATIG N VOLUM E: SECONDARY COMPARTMENT 338 GALLONS B 0 SCAL GALLON LOW PROFILE SEPTIC TANK - 17RCOUN DAR3 IE S UNLIMITED INC CIVIL ENGINEERING, LAND SURVEYING€ BEYOND 923 Cooper Avenue, Sit 201 Glenwood Springs, CO 01601 tele:970.945.5252 www.hu-ific.com Engineer or Surveyor Seal L�CF,L OQ`PDO ON • tl'F a Wq� c�\'.• �� • V O :oQ 3/27/24 y' 37110 FSSIDNA�`��� Client Information: Stephen Zanetich 8 0akview Terrace Swedenhoro, NJ 08085 856.472.1831 Subsurface Utility Engineering (SUE) Required Project: N If "Yes", SUE Certification by: Firm: NIA Job #: NIA Date: NIA NORTH 0 20' 4U Scale: l" = 20' Know what's below. Call before you dig. vi CL) E V N o V C y/�`� E (_1 CL) 13 d o >_ U a� CV L CsLD •v *� G a.) C) C= y NV N d� O Agency Approval Agency: Dept: By: Date: Comments: Date Revision Project No.: Sheet 25019 Filename: Designer: Designer. C4,1 dkw Drafter: dkw Date: 8127125