HomeMy WebLinkAboutOWTS Permit # SEPT-9402 (signed)
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 2027 County Road 245, New Castle Parcel No.: _21252500074
Owner Name: Robert Jones Owner Phone: (303) 882-5800
Designer: Huddleston-Berry Engineering Designer Phone: (970) 225-8005
Number of Bedrooms: 2 Minimum Tank Capacity: 1000-gallons Minimum Absorption: 720 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-9402_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _09/05/2025____________________ Expiration Date_09/05/2026_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with scope of work and site plan as
submitted by Huddleston-Berry Engineering dated July 25, 2025. Changes to the design and permit
must be approved by Garfield County Public Health prior to construction.
The new OWTS will serve a new two-bedroom residence. A new 1000-gallon two compartment
septic tank set level with access to grade with an effluent filter installed in the outlet tee of the tank
will be installed. The septic tank shall be on the Colorado Department of Public Health and
Environment’s approved septic tank list. Effluent will gravity flow to a new distribution box set level
with access to grade which will distribute effluent to 768 ft 2 of STA via two additional downstream
distribution boxes. The new STA area will consist of two gravelless chamber beds at a maximum
depth of 4ft below ground surface, each bed consisting of four rows of 8 ‘Quick 4’ chambers (64
chambers total). Inspection ports will be installed at each corner of each bed. Maintain all setbacks
and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
09/05/2025
Issued By: Garfield County Environmental Health
Department
Date