HomeMy WebLinkAboutApplicationGarfield County
Com munity Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
l970l s4s-8212
www. ga rfieldcountyco.gov
INVOTVED PARTIES
BUILDING PERMIT
APPLICATION
TYPE OF CONSTRUCTION
DemolitionCommercial/Multi-Fam
Manufactured Home or Tiny Home (Single or Multi-Level)
Residential (SF, Duplex orTownhome)Reroof
Accessorv Dwelling Unit (ADU)- MAXIMUM SIZE OF 1,200 SQUARE FEET
Manufactured Home lnstaller:Phone: ( )
Mailing Address
Email Address:
PROJECT DETAILS
work: F x\r," rooq a,ldeA an. forch panndJ \a
Kl6sa0lJob Address:
Assessor's Parcel Number:
5ub.Lot Block
Owner's Valuation of Work: S Property Size (Sq. Ft. or AEres)
# of f loors: 4
atg' L
( ref\phone: (UIg tg* b\q-t^dlL
O0
Email Address:
Property Owner:
Mailing Address:
Phone:Contractor:
Mailing Address
Email Address:
Phone: ( )Architect:
Mailing Address
Email Address:
)Phone:(Engineen
Mailing Address
Email Addressr
XClass of Work:New $Remodel/Alteration
Addition
DetachedGarage:Attached
Sq. Ft. of Building:Height:t
F
Septic:
Natural Gas
Kle'on'n"
Electric
Community
OtherType of Heat:
Driveway
Permit:
Exempt
PROJECT DETAITS CONTINUED
Permit #:
NOTICE
Authoritv. This epplication tor o Building Fermit must bc signed Lry thc Owner of the property, dcscribed abovc,
oranauthorizedagent. lfthesignaturebelowisnotthatoftheOwner,aseparateletterofauthority,signedby
the Owner, must be provided with this Application.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
VoidPermit. ABuildingPermitbecomesnull andvoidiftheworkauthorizedisnotcommencedwithinl80days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICATION
I hereby certify that I have read this Application and that the information contained above is true and correct. I
understand that the Building Division accepts the Application, along with the plans and specifications and other data
submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness
of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as
Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln
consideration of the issuance of the Building Permit, lagreethat land myagentswillcomplywith provisionsof any
federal, state or local law regulating the work and the Garfield County Building Code, OWTS regulations and
applicable land use regulations (County Regulation(s)). All County development requiring a permit, except for
residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building
Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the
structure(s) and facility(ies), described above, are not in compliance with County Regulatit;n(s) or any r.rther
^^^t:^^Lt^ t^,.,dPPrLdurE rdw.
lherebygrantpermissiontotheBuildingDivisiontoentertheproperty,describedabove,toinspectthework. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring
the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the
structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this
Application, including submittals, and inspections of the work by the Building Division do not constitute an
acceptanceof responsibilityorliabilitybytheCountyoferrors,omissions,ordiscrepancies. AstheOwner, I
acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with
me and my authorized agents, including without limitation my architect designer, engineer and/ or builder.
Property Owner Print and Date
I hereby acknowledge that I have read and understand the Notlce and Certification above, as well as, have
provided the required information which is correct and accurate to the best of my knowledge.
hc..r\ dror,un^ 4.fl^,,,,n,^ l. ff -1l^ -z\
OFFICIAT USE ONtY
Special Conditions:
Adiustcd Valuation
9g P.e)
Plan Cheek Fee:'e8a_67 43i.C5
Permit Fee:utanu. Home Fee:tvltsc. FeeS:
OWTS No:Total Fees:-T12"72 Fees Paid:
8A+ot
Balance Due:Aax 1l
l, ,., ,9t ffisqqql
Setbacks:OCC Group:Const. Type:tonin?_
?-f-25BUILDING / PLANNING DIVISION
Daie
ENERGY COMPLIANCE SHEET REQUIREMENTS:
Effective June 30, 2023 Please provide details showing how building complies / meets Garfield County's
adopted 2018 IECC and Glimate Zone 5.
Depict and show outline the structure's building thermal envelope. Outline should clearly show portions
of the building to be conditioned inside the envelope (and label or othenrvise identify any areas remaining
unconditioned outside this envelope)
Energy Compliance Plan should further include:
Chosen Energy Compliance Path. Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value
and U-Values to comply with IRC Table R402J.2
. U-Factor Alternative: Provide a ResCheck Report
. Total U-Factor Alternative: Provide software generated submittal design reports and inspection
checklist for any RESNET ERI index or other performance path designs
Air sealing details around openings, pipes, penetrations, joints
Fenestration U-factors
Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel
types, locations
Energy efficient lighting specifications - 90% to be high-efficacy (LED complies)
Manual J Report required for new building structures and new equipment installations.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
. SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a soils report, then a
copy of the soils report is required to submit a building permit application.
. Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.. Foundation plan showing complete footing and foundation dimensions.
. Footing and foundation details specifying reinforcement and referenced on plans.
. Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.
. Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold untilthe required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as
well as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
t fi - \tt -15owner p,.int, '$rcit) U t(Crfl Zc.r Sign
Guffield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
(9701 94s-82L2
www.ga rf ieldcou ntvco.gov
plicant: Ariel Carranza Phone
Project Address:1813 CR 256
Su bdivsion:Lot Block
Tvpe of Space Square Feet Valuation
Finished Living Space (N/A for Manufactured Homes)S1o1.4s
Unfinished Basement s32.oo
Crawl Space s24.oo
Garase (Attached)S32.oo
Garaqe (Detached)s40.00
Covered Patio/Deck s24.00
Uncovered Patio/Deck 1600 s18.00
Misc: Remodeled area 520.2s
Misc:$o.oo
.1.,.,':. t:'i t :i :,1 :.';'ti' ; y,l
:':..: ,1,;,':.:,i.-
Manufactured Home Set-Up Fee
Sinele Level (5400)5o.oo
Multi-Level (S600)so.oo
Septic Fee
New lnstallation 600
Septic - Major Repair (New System & STA) (S0OO1
Septic - Minor Repair (Tank Onlv) (5200)
Alteration (S200)
Vault & Haul (S75)So.oo
'i,..1 lt , :r;,: : li :':'-:-: l:iri
BUILDING PERMIT
FEE ESTIMATE
WORKSHEET
5280.s7Plan Review Fee
$431.6sBuilding Permit Fee
Manufactured Home Set-Up Fee
Septic Fee (OWTS)
Other (Ex: Road lmpact Fee)
***All fees are estimates untilfinal plan review is completed***