HomeMy WebLinkAboutRescheck Reporti
Generated by REScheck-Web Software
Com pl iance Certificate
Ctnt rs)
Project Lot 5 The Rapids on The Colorado. Kenia Perez Residence
Energy Code:
Location:
Construction Type:
Project Type:
Project SubType:
Orientation:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
Construction Site:
Lot 3 The Rapids on The Colorado
New Castle, CO 81"647
2018 |ECC
Garfield County, Colorado
Single-family
New Construction
None
Bldg. faces 18O deg. from Nofth
3,084ftz
L2o/o
5 (8499 HDD)
false
false
false
false
false
Owner/Agent:
638
2,440
47
158
264
!44
L6
Designer/Contractor:
Mic Baca
Studio M Engineers
970 366 8690
N
Compliance: 2,570 Better Than Code Maximum UA: 394 Your UA: 384
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in RESCheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
-ari
-
N
Ceiling Over Garage Bonus Room: Flat Ceiling or
Scissor Truss
Main Level Ceiling: Flat Ceiling or Scissor Truss
Ceiling OVer Stairs: Flat Ceiling or Scissor Truss
2nd Level Back Wall: Wood Frame, 16" o.c.
Orientation: Back
2nd Level Right Wall: Wood Frame, 16" o.c.
Qrientation: Right side
2nd Level Front Wall: Wood Frame, 16" o.c.
Orientation: Front
2nd Level Front Window: Vinyl Frame
Orientation: Front
49.0
49.O
49.0
20.0
20.0
20.0
0.0
0.0
0.0
0.0
0.0
0.0
0.026
0.026
0.026
0.059
0.059
0.059
0.300
0.026
0.026
0.026
0.060
0.060
0.060
0.300
t7
63
L
9
L6
B
5
t7
63
1
9
16
B
5
Compliance: Passes using UA trade-off
Cavity
R-Value
Cont.
R-Value
Prop. Req.
U-Factor U-Factor
Gross Area
Assembly
Perimeter
or UA UA
Prop. Req
ertiject Title: Lot 5 The Rapids on The Colorado. Kenia Perez Residence
Data filename:
Report date: O5l2Ol25
Page 1 of 2
Gross Area
or
Perimeter
Cavity
R-Value
Cont,
R-Value
Prop. Req.
U-Factor U-Factor
Prop
UA
Req
UAAssembly
2nd Level Left Wall: Wood Frame, 1.6" o.c.
Orientation: Left side
1st Level Back Wall: Wood Frame, L6" o.c.
Orientation: Back
1st Level Back Wall Doors: Glass Door (over 50olo
glazing)
0rientation: Back
Lst Level Back Wall Windows: Vinyl Frame
Orientation: Back
1st Level Right Walls: Wood Frame, 16" o.c.
Orientation: Right side
1st Level Right Wall Window: Vinyl Frame
Orientation: Right side
Lst Level Front Wall: Wood Frame, 16" o.c.
Orientation: Front \
Man Doors to Garage: Solid Door (under 50%
glazing)
Orientation: Front
Lst Level Front Wall Door: Glass Door (over 50olo
glazing)
Orientation: Front
1st Level Front Wall Windows: Vinyl Frame
Orientation: Front
1st Level Left Walls: Wood Frame, L6" o.c.
Orientation: Left side
Front Foundation Wall: Solid Concrete or Masonry
Wall height: 2.7'
Depth below grade: 2.2'
lnsulation depth: 2.7'
Left Crawl Space Wall: Solid Concrete or Masonry
Wall height: 2.7'
Depth below grade: 2.2'
lnsulation depth: 2.7'
Back Crawl Space Wall: Solid Concrete or Masonry
Wall height: 2.7'
Depth below gradei 2.2'
lnsulation depth: 2.7'
Right Crawl Space Wall: Solid Concrete or Masonry
Wall height: 2.7'
Depth below grade: 2.2'
lnsulation depth: 2.7'
254
570
1r.3
97
545
t6
62r
2t
49
68
537
201,
r.56
20r
1"56
20.0
20.0
0.0
0.0
0,059
0.059
0.300
0.300
0.059
0.300
0.059
0.160
0.300
0.300
0.059
0.055
0.060
0.060
0,300
0.300
0.060
0.300
0.060
0.300
0,300
0.300
0.060
0.055
15
2t
34
29
31
5
28
3
t5
20
32
10
15
22
34
29
3220.0 0.0
20.0 0.0
20.0 0.0
29
8
4 8
5
6
L5
20
32
100.0 15.0
0.0 r_5.0 0.055 0.055
0.0 30.0 0.030 0.055
8
0.0 15.0 0.055 0.055 10 10
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 20L8 IECC requirements in
REScheckVersion : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist.
Name - Title Signature Date
Project Title: Lot 5 The Rapids on The Colorado. Kenia Perez Residence
Data filename:
Report date: 05l20l25
Page2 of 2
fr 2018 IECC Energy
Eff iciency Certif icate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces) :
Window
Door
Heating System:
Cooling System
Water Heater:
Name:
Comments
20.o0
15.OO
o.oo
49.O0
o.30
o.3('
Date:
Insulation Rating R-Value
Glass & Door Rating U-Factor SHGC
Heating & Cooling Equipment Efficiency