HomeMy WebLinkAboutBolt and Weld Inspection ReportINDUSTRIAL INSPECTION
SERVICES
Special Inspector's Final Report
REPORT DATE: September 15**, 2025
JOB NAME: Brettleberg Deck
ADDRESS: Buttermilk Ski Area, Glenwood Springs
BUILDING TYPE: Deck / addition
INSPECTION DATES: July -August 2025
PERMIT #
GENERAL CONTRACTOR: Neuman Construction
WALL TYPE: Wood framed / Structural steel
DESCRIPTION OF INSPECTION WORK PERFORMED: Speclal Inspecton provided to monitor, witness and verify shop
welding /fabrication and field welding / erection of structural steel as required by the 2021 IBC, structural engineer and
local bullding jurisdiction.
LOCATION IN STRUCTURE: Special inspection provided to witness and verify shop / field welding and epoxy anchors for
Installation of structural steel for deck addition as detailed and approved by structural engineer.
REMARKS FOR STRUCTURAL STEEL: Witness and monitor shop / field welding / erectlon of structural steel
columns/TS beams as detalled and designed by structural engineer. Welding was performed by certified welders employed
by IRMW Steel using approved filler materials and processes. Weld discontinultles were corrected in Inspector's presence
and re-welded in accordance with AWS D1.1 / AISC specifications. Mill certifications for steel elements reviewed and kept on
file by fabricators. Epoxy anchors Installed using Hilti- HIT HY 200 V3 per manufacturer's specifications. No problems
Upon the completion of the work described herein, the work performed, the materials utilized and the processes used appear
to fully comply with the approved plans and applicable codes.
REMARKS GENERAL: Speclal inspection on this project was performed per the special inspection requirements adopted
from the 2021 IBC by the Garfleld County Department as part of the approved plan.
ALL WORK REFERENCED ABOVE WITNESSED BY INDUSTRIAL INSPECTION SERVICES PERSONNEL, PERFORMED JULY
WAS SATISFACTORILY COMPLETED AND CONFORMS TO THE APPROVED PLANS, THE 2021 INTERNATIONAL BUILDING CODES
(IBC), THE ADOPTED PROVISIONS OF THE AVS D1,1 AND THE AISC MANUAL OF STEEL CONSTRUCTION 360, SECTION N. THIS
STATEMENT APPLIED DIRECTLY TO THOSE PORTIONS OF THE STRUCTURE WHICH SPECIAL INSPECTION WAS PRESCRIBED
1-85