HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-07 -25-9410
BRADLEY & RUTH BIRKELO
New Single-family dwelling w/ attached garage
382 River Bend Wuy, GSW
lronbridge PUD, Lot 91 - 239512118091
1) ALL WORK SHALL COMPLY W|TH THE 201s TNTERNATTONAL RESTDENTTAL CODE (r.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY CON/MUNIry DEVELOPMENT WEBSITE FOR
ADDITIONAL I NFORMATION.
6) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTTNG TNSPECTTON AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
2,500 PSF soil bearing. Provide compaction report if any structural fill.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR BUTLDTNG TNSPECTOR AT TrME OF
FRAME INSPECTION.
8) WET BAR: AN AREA OF A ROOM THAT IS DESIGNED TO BE USED FOR SERVING BEVERAGES THAT
MAY ONLY HAVE A SINGLE BAR SINK AND NO STANDARD SIZE KITCHEN APPLIANCES SUCH AS A
STOVE, OVEN, DISHWASHER OR FULL-SIZE REFRIGERATOR. COUNTER SPACE IS LIMITED TO 25
SOUARE FEET.
9) ',FLEX ROOM',LOCATED OUTSTDE LOWER LEVEL GUEST BEDROOM MUST NOT BE USED FOR
SLEEPING PURPOSES (CONTAINS NO EMERGENCY ESCAPE AND RESCUE OPENINGS TO YARDS),
FLEX ROOM SHALL FURTHER BE SUPPLIED LIGHT AND VENTILATION PURSUANT TO ADOPTED 2015
IRC SECTIONS R3O3 AND R303.4.
10) A LOr TMPROVEMENT CERT|F|CATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE - INCLUDING PROPOSED ROOF OVERHANGS,
DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH MINIMUM SETBACKS AND/OR
BUILDING ENVELOPE REOUIREMENTS.
1 1 ) BLOWER DOOR TEST rS REOUTRED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFTELD
COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
12) PRESCR|pTtVE PATH USTNG 2018 rECC TABLE R402.1.2 rS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME. CORRECTED MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES
TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE
m1507.3.3(1)AND (2) SHOWN ON COVER SHEET.
$