HomeMy WebLinkAboutOWTS Permit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 826 County Road 237, Silt Parcel No.: 212736200080
Owner Name: Gilberto Montanez and Olga Gutierrez Owner Phone: (970) 309-1978
Designed By: Radian Engineering Designer Phone: (720) 224-1095
Contractor: Miguel Salvidrez Contractor Phone: (970) 309-5416
Number of Bedrooms: _2_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 840 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-9308_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _09/23/2025____________________ Expiration Date_09/23/2026_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report, design, and design
revisions as submitted by Radian Engineering, LLC dated July 22 and September 18, 2025. Changes to
the design and permit must be approved by Garfield County Public Health and the designer prior to
construction.
The new OWTS will serve a proposed two-bedroom residence. The system will consist of one two-
compartment 1,000-gallon septic tank with water-tight risers and an effluent filter in the outlet tee
of the tank. The septic tank shall be on the Colorado Department of Public Health and Environment’s
approved septic tank list. Effluent will gravity flow to a level manifold to distribute effluent to 1,008
ft2 of STA. The new STA will consist of a 12 ft by 88 ft gravelless bed containing 4 rows of 21 ‘Quick4’
chambers (84 chambers total). Inspection ports shall be installed at all four corners of the bed.
Maintain all setbacks and elevations as designed.
To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to
notify the start of OWTS construction. Contact the designer and Garfield County Public Health at
least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS
COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC
HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
09/23/2025
Issued By: Garfield County Environmental Health
Department
Date