Loading...
HomeMy WebLinkAboutEngineer's Framing DetailErnest Kollar Engineers, Inc. 320 Main St., Suite 203 Carbondale, CO 81623 Phone (970) 963-3223 erniekollar@gmail.com September 29, 2025 To: Garfield County Building Department Judy Spasser Re: Lot 8, Wooden Deer, Carbondale, CO Judy Spasser Residence The new window, spanning 61 inches with a 3-2x8 header and single trimmers and single king studs, that was added to the south facing master bedroom wall is adequate, as framed; however, please note the following and educate the framers accordingly: The IRC requires double trimmers for spans exceeding 48 inches. Double king studs would normally be required to replace the continuous studs that the window omits. For better serviceability, another king stud could be added to each side. The single trimmers are only adequate because the opening is in a gable wall and the tributary roof loads are less than if the trusses were bearing on the wall. Please call with any questions, Ernest Kollar Ernest Kollar, PE O LIDCAERNOSL EO DC P R R E O E F N E ISGSNIOE N LA UL A K OP LT LS AE RN R IIE27036 Ernest Koll a r 09/29/202 5