Loading...
HomeMy WebLinkAboutApplicationGarfield CounE RECEIV Development Department fr tii: ") J .ldlrlL 108 8th Street, Suite 401 F\{'rr'r c- i tt{ '} Glenwood springs, co 81601 $,rrt.tFiLLil CCILrtd t"y l970lg45-82t2 .-l 0 1,,1 hr U i{, TY n E vE l O p M E H fuww,ga rfield-countV.com .b {s BUILDING PERMIT APPLICATION DemolitionCom mercial/M ulti-Family Manufactured Home or Tiny Home (Single or Multi-Level) ReroofResidential (SF, Duplex or Townhome) Accessory Dwelling Unit (ADU)- MAXIMUM SIZE OF 1,200 SQUARE FEET C^oh Phone: t3o3l ?-/8 zoq+3,tsc n ^JO I(,r,o c.t1/€Ottabe+ln AeF-r,r , # fr l, &r-t +e tru-tl, Property Owner: EmaitAddres'' Se!'ftl Mailing Address: phone: &70 | Aoq "7 ta I tlw.d 6A Dr htl Contractor: ulhn holrttct-t I' Cnrtr't Mailing Address: Email Address: w d Phone: t4oLl o-71 8€Oz- od Architect: dto,n@rvl fMailing Address: Email Address: tq€Lf t n 7 ff1 Phone fl1ot7z-i QDeo Mailing Address Email Address: Engineer: Email Address: Phone:Manufactured Home lnstaller Mailing Address Owner'sValuationofWork: $ ZOO, OOO PropertySize (Sq. Ft. orAcres): Describe work: I nlerl oa 5a,1 '+he re?tctc-c tven+ Sub.O*L gw Height Yi d n OI o vew\ode( a$d f I LLI b,, ura*-ryt oFsorne t Sq. Ft. of Building:3()-b Assessor's Parcel Number: Job Address:b-? lot 5 slock 3 f of Floors: 4 reumQ Garage hed Detached kc Type of Heat:Natural Gas Propane Electric Other Authoritv. This application for a Building Permit must be signed by the Owner of the property, described above, or an authorized agent. lf the srgnature below is not that of the Owner, a separate letter of authority, signed by the Owner, must be provided with this Application. legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Division. Other Permits, Multiple separate permits may be required: (1) State Electrical Permit, {2) County OWTS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after comrnencentent. lherebycertifythatlhavereadthisApplicationandthattheinformationcontainedaboveistrueandcorrect. I understand that the Building Division accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, OWTS regulations and applicable land use regulations (County Regulation(s)). All County development requiring a permit, except for residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions, or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer andl or builder. I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have provided the required informatio 3u-savt EIttz-b*{n accurate to the best of my knowledge. glzt izg Date L lzr n which is td.e. Property Owner Print and Sign special conditions: -1 ^ .- .. J t / -,. ^^/ .rr,tnrr /r\ trw n a /,?ro€e qTmtrrcq c-..u/v/// / Iu/v> Adiusted Valuation:gz^'7h)"d 'vlgz:'a7 'bwt]|76 Manu. Home Fee;*.--.---Misc. Fees: "'niF*&,Bf Fees Paid l-4?/J et 'i:w]:w Wnq,R OWTS No: 4- Setbacks:OCC Group:tRe const'rleek'z>zotp' BUtLD|NG / PLANNTNG DlVlStON : Signed Approva!n-+6 14,"-4 ENERGY COMPLIANCE SHEET REQUIREMENTS: Effective June 3A, 2023 Please provide details showing how building complies / meets Garfield County's adopted 2018 IECC and Climate Zone 5. Depict and show outline the structure's building thermal envelope. Outline should clearly show portions of the building to be conditioned inside the envelope (and label or otherwise identify any areas remaining unconditioned outside this envelope) Energy Compliance Plan should further include: Chosen Energy Compliance Patho Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value and U-Values to comply with IRC Table R402.1.2 o U-Factor Alternative: Provide a ResCheck Report r Total U-Factor Alternative: Provide software generated submittal design repofts and inspection checklist for any RESNET ERI index or other performance path designs Air sealing details around openings, pipes, penetrations, joints Fenestration U-factors Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel types, locations Energy efficient lighting specifications - 90% to be high-efficacy (LED complies) Manual J Report required for new building structures and new equipment installations. STRUCTURAL PLANS: Please provide the following information on the structural plans. o SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific soils investigation report or if Structural plans make a specific reference to a soils report, then a copy of the soils report is required to submit a building permit application. o Design specifications to include roof and deck snow load, wind and seismic design and frost depth.r Foundation plan showing complete footing and foundation dimensions. r Footing and foundation details specifying reinforcement and referenced on plans. r Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses specified. Pre-manufactured structures require the engineers stamp, signature and date. . Framing /connection details, braced wall lines, shear wall schedule, location and hold downs. NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold until the required information is provided. Work may not proceed without the issuance of a permit. The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as well as any Road lmpact fees will be collected when the permit is issued. The permit application must be signed by the owner or by person having written authority from the owner to act as their representative. Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO inspection requirements will be attached to your approved field set of plans.) I hereby acknowledge I have read, understand and will abide by the requirements of this checklist. Ougndt7@t{1cr.^g s l2z/zs8lz:lzrOwner Print: €rC-Wodu Sign: RESIDENTIAL ENERGY EFFICIENCY R402.f .1 Vapor retarder. Wall assemblies in the build- ing thermal ent,elope sha.ll comply with the vapor retarder requirements of Section R702.7 of the International Resi- dential Code or Secfion 1404.3 of the International Build- ing Code, as applicablc. R402.f,2 Insulation and fenestration criteria. The building thermal envelope shall meet the requirements of Tabte R402.1.2, based on the climate zone specified in Chapter 3. R402.1.3 R-value computation. Insulation material used in layers, such as framing cavity insulation or continuous insulation, shall be summed to compute the corresponding component R-value. The manufacturer's settled R-value shall be used for blown-in insulation. Computed R-values shall not include an R-value for other building materials or air fi.lrrrs. Wrcrc irrsrrlalerl sir,lirrg is uxer.l hrr'lhc purpuse r-rf complying with the continuous insulation requirements of Table R402.1.2, the rnanufacturcr's labclcd 1l-value frl' the insulated siding shall be reduced by R-0.6. R402.1.4 U-factor alternative. An assembly with a U-fac- tor equal to or less than that specified in Table F.402.1.4 shall be an altemative to the R-value in Table R402.1.2. 2018 INTERNATIONAL ENERGY CONSERVATION CODE6 TABLE R4O2.1.2 INSULATION AND FENESTBATION REOUIREMENTS BY COMPONENT" NR = Not Required, For SI: 1 foot = 304.8 mrn. a. R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or design thickness of the insulation, the installed R-value of the insulation shall be not less than the R-value specified in the table. b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exceptlon: In Climate Zones I through 3, skylights shall be permitted to be excluded from glazed fenestration SHGC requirements provided that the SHGC for such skylights does not exceed 0.30. c. "10/l3"meansR-l0eontinuousinsulationontheinteriororexteriorofthehomeorR-l3cavityinsulationontheinteriorof thebasementwall. "15/1 9" means R- I 5 continuous insulation on the interior or exterior of the home or R- I 9 cavity insulation at the interior of the basement wall. Atternatively, compliance with " 15/19" shall be R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior ol exterior of the home. d. R-5 insulation shall be provided under the full slab area ofa heated slab in addition to the required slab edge insulation R-value for slabs. as indicated irr the tabte. The slab edge insulation for heated slabs shall not be required to extend below the slab. e. There are no SHGC requirements in the Marine Zone. f. Basementwallinsulationisnotrequiredinwarm-humidlocationsasdefinedbyFigureR30l.landTableR301.l. g. Alternatively, insulation sufficient to fill the fi'aming cavity and providing not less than an R-value of R-19. h. The ilrst value is cavity insulation, the second value is continuous insulation. Therefbre, as an example, "13+5" means R-13 cavity insulation plus R-5 continuous insulation. I i. MasswallsshallbeinaccordancewithSectionR402.2.5.ThesecondR-valueapplieswheremorethanhalfoftheinsulationisontheinteriorofthemasswall. TABLE R402,1,4 EQUIVALENT U.FACTORS" CLIMATE ZONE FENESTRATION U.FACTOR SKYLIGHT U.FACTOR CEILING U.FACTOR FRAME WALL U.FACTOB MASS WALL U.FACTORb FLOOR U+ACTOR BASEMENT WALL UfACTOR CRAWL SPACE WALL U-FACTOR t 0.50 0.75 0.035 0.084 o.197 0.064 0.360 0.477 2 0.40 0.65 0.030 0.084 0.165 0.064 0.360 0.47'l I 0,32 0.ss 0.030 0.060 0.0s8 o.047 0.091"0.136 4 except Marine o.32 0.55 0.026 0.060 0.098 0.047 0.059 0.065 5 and Marine 4 0.30 0.55 0.026 0.060 0.082 0.033 0.050 0.05s 6 0.30 0.5s 0.026 0,045 0.060 0.033 0.050 0.055 7and8 0.30 0,55 0.026 0.045 0.0-57 0.028 0.050 0.055 o, Nonfonestrttion U-factors shall bc obtaincd iiom mcasurement, calculation or an approved source. I b.MasswallsshallbcinaccordancewithScctionR402.2.5.Whcremorethanhalftheinsulationisontheinterior,thcmasswallU-fbctorsshallnotexceed0.lT in Climate Zone 1,0.14 in ClimateZone2,0.12 in Climate Zone 3, 0.087in ClimateZnne 4 except Marine,0.065 in Climate Zone 5 and Marine 4, and 0.057 in Climate Zones 6 through 8. c. In warm-humid locations as detined by Figure R30'l .1 and Table R301 .1, the basement wall U-factor shall not exceed 0.360. CLIMATE ZONE FENESTRATION IAFACTORb SKYLIGHTb U+ACTOR GLAZED FENESTRATION SHGCb,' CEILING B.VALUE wooD FRAME WALL F.VALUE MASS WALL R-VALtJEI FLOOR B.VALUE BASEMENT" WALL B.VALUE SLABd B.VALUE & DEPTH gHAWL SPACE WALL R.VALUE I NR 0.75 0.25 JU l3 314 l3 o 0 0 2 0.40 0.65 o.25 3E l3 4/6 l3 0 0 0 3 0.32 0.55 0,25 3E 20 or l3+5"8l13 l9 51t3,0 slt3 4 except Marine 0.32 0.55 0.40 49 20 or I 3+5h 8113 19 l0 /13 10,2tt tolt3 5 and Marine 4 0.30 0.55 NR 49 20 or l3+5n 13117 30s t5/19 l0,2tt t5ltg 6 0.30 0.55 NR 49 20+5" or l3+10"15121)308 t 5/t9 10,4 tt t5119 7and8 0.30 u.55 NR 49 20+5" or 1 3+10"19121 38s 15119 10,4 ft t5lt9 R-30 Gurfteld County BUILDING DEPARTMENT 108 Eighth Street, Suite 407, Glenwood Springs, CO 81601 Tel: (970) 94s-8212 PLAN REVIEW C H ECKLIST Permit No: b LRge*Z# ?4qS Building lssues / Engineered Foundation Driveway Permit Planning/Zoning lssues ruAa Des 2729t 4 /ar lr+-S Property Line Setbacks 35 ft. Stream Setbacks Flood Plain Building Height Zoning Sign-Off Grade/ Topography 40% Planning lssues Subdivision Plat & Summ Surveyed Site Plan na A n bedrrzrn Seotic Permit and Setbacks r ( Sre.otatn ) clroe/Topography 3o%/ # I Road tmpact Fees ,wn;hnL(SAttach Residential Plan Review List Subdivision Plat Notes Fire Department Review Valuation Determination/ Fees Red Line Plans/ Stamps/ Sticker Conditions Application Signed Energy Compliance Path/Plan ReceiVed Plan Reviewer to Sign APPlication Parcel/Schedule No. 40# Snowload Letter - Manuf. Homes Soils Report Rarde/ /afy's,f,x #50 fzlrM,@ N4 efit Caur*:r Arna'/ FLS JeV,;M}n aralzrP&"io/aAz"l3 fu/rwn (y elrcf ruwved {-*-}r^ - /ai'ttb / eite / .ffi ctA-) Lf P: 9-2b^ z5 e{i9h ^)l{a 0wT3 AinLF 7.27 acres 107 Srtn (rril 2ahlYlendowg 7rd flz,5 no4 'y rl "r,lhile bfnder" buill nqr &bdr"o'"2) WD'--QQ l+t6 ,"r7 eLrfa I1 f.oP*J 4r^okes Iol ,iAu /zzafl 70n fr3 It"ovfatl ["Wo Ie', q-Voa-5 hio|"r'i " )eYtr- otl7z (Sepl ll, nqt) n room tnCr(L*-(zbed,, \-/ Ivu loN 0 R o\Nw-orllor to*6*Z 6 lon/tr >E//10 bh na b,&, dn Ar*furtLfA* N/4 clns*p de/e,bd