HomeMy WebLinkAboutInsulation CertificateAccurate lnsulation Permit#:
Job lnformation
Builder:J[;rn "\AM.
Community:Lot:
Address: [eqq Cor^{,,, Pi. zfr
City s. tI IState ziP: ?ru< z
Air Leakage Test Results Possing results must meet either the Perfurmonce, Prescriptive, or ERI Method
Prescriptive Method- The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour at pressure of O.2-inch w. g. {50 Pascals} in Climate Zones 1 and 2.
Performance or ERI Method-the building or dwelling unit shall be tested and verified as having an air leakage rate of
not exceeding the selected ACH (50) value, as shown on Form R405-202 (Performance) or R406-2020 (ERl), section labeled
as infiltration, subsection ACH50.
ACH (50) specified on Form R/m5-202-Energy Calc (Pefurmance) or R406-2020 (ER,):7 'a-o/
?+
ven
cFM (s0)
32, (off
Building Volume
2.7
ACH (sol
Z PASS
Method for Calculating building volume:
o Retrieved from architectural plans
o Code software calculated
oAield measured and calculated
During testing:
t. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the
intended weatherstripping or other infilitration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not
sealed beyond intended infiltration control measures.
3. lnterior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continous ventilation systems and heat recovery ventilatiors shall be closed and
sealed.
5. Heating and cooling systems, if installed at the time of the tst, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Gompany
company Name: Accurate lnsulation Phone: 970-296-004t
Signature of Tester:Dateof1"r1. /o / a3 / Z(
Printed Name of Tester: Rich Romero Lice nse/Ce rtifi catio n : 5O7 2554
lssu i ng Authority: Building Performa nce lnstitute