HomeMy WebLinkAboutEngineer's OWTS Design Plana 4. .7 \ D -Q \ FT] / INN PORT AT EACH D OF END OF EACH TRENCH, TYP / �PA��� GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL. BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.05'±. (TYP.) REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. DO NOT WALK ON OR COMPACT BOTTOM OF TRENCH. 36' MAX. - INFLOW PIPE SHALL ENTER THE UPPER KNOCKOUTS ' y END A 100 LF 4'0 SCHAD P / I STUB LINE @2%MIN AND INSTALL TWO-WAY CLEANOUT (FOR POSSIBLE FUTURE ADU) 11 I � I I f i IR FROM PROPERTY LINE II If INSTA A TWO-WAY CLEANOUT OUTSI ETHE BUILDING 4'0 SCHAD PVC IEWER W/ 45' BENDS W & WYE(S) @ 2%. MIN. NSTALL 1500-GALLON -�-TWO-COMPARTMENT SEPTIC TANK WITH AN EFFLUENT FILTER IN THE OUTLET RISER (SEE SETBACK NOTES) / I / I I� X Iw 0 [--10' FROM PROPERTY LINE X SYSTEM DESIGN & CONSTRUCTION NOTES: 1. THIS DESIGN IS FOR A REPLACEMENT ABSORPTION FIELD. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH COPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM OWTS REGULATION MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE 1 ) DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72-HOURS PRIOR TO THE DESIRED TIME OF BACKFILLING. - 2. DEMAND CALCULATIONS (SEC.43.6.A2.h) 2A. THREE (3) BEDROOM PRIMARY RESIDENCE AND A POTENTIAL FUTURE TWO (2) BEDROOM ACCESSORY DWELLING UNIT (ADU) USING TREATMENT LEVEL 1 (TL1). 2.B. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BODS): 2.B.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOD5 Tbslday 2.8.2. ADWF: 2.8.2.1. PRIMARY RESIDENCE = 75 gpd " (3 BEDROOMS' 2 PERSONS/BEDROOM) = 450 gpd 2.82.2. ACCESSDRY DWELLING UNIT = 75 gpd . (2. BEDROOMS' 2 PERSONS/BEDROOM) = 3DO gpd 2.523. ADWF = 750 gpd 2.B.3. BODS = 0.20 Ibs/day - 10 PERSONS = 2.0 Ibs/day BODS mg/L = B005'1,000,000 = 2.0 Ibs/dav'1 AOQ000 = 320 mg/L ADWF'8.34 750 gpd"8.34 2.6.4. CBODS = ROD, ` 0,85 = 272 mg/L 3. SEPnCCTANK (SEC.43.9.B.2.a): 3.A. 48-HOURS OF MINIMUM DETENTION TIME: ADWF " 48 hrs/24 hrs = 750' 48 hrs/ 24 his = 1500 GALLONS. 3.8. INSTALL 1,500 GALLON TWO -COMPARTMENT SEPTIC TANK WITH EFFLUENT FILTER IN THE OUTLET RISER. 3.C. THE. TANK IS NOT SUBJECT TO BUOYANCY. 4. ABSORPTION AREA CALCULATIONS: 4.A. THE ABSORPTION AREA SLOPES AT APPROXIMATELY 5%TO 10%. 4.13. LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.35 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.C. MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 750 = 2,143 S.F. LTAR 0,35 gpd/S.F. 4.0. SIZE ADJUSTMENT FACTORS: GRAVITY TRENCH = 1.0;, CHAMBERS = 0.7 (TABLE 10-1A). 4.DA. A,adj=2143 SF'1.0"0.7=1500 SF 4.E. GRAVELLESS CHAMBER TRENCH. SYSTEM: - 4.E.I. .INFILTRATOR QUICK4: 1500 SF/ 12 SF/UNIT = 125 UNITS. INSTALL 128 UNITS IN EIGHT (8) TRENCHES CONTAINING SIXTEEN(16) UNITS EACH. 4.E.2. ADS ARC 36: 1500 SF / 15 SF/UNIT = 100 UNITS. INSTALL 104 ONO IN EIGHT (8) TRENCHES CONTAINING THIRTEEN (13) UNITS EACH. 5. THIS SYSTEM IS SIZED FOR TYPICAL HOUSEHOLD WASTES ONLY, BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE. INTRODUCED INTO THIS SYSTEM. BACKWASH AND FLUSHING FLOWS SHALL BE DISPOSED OF WITHIN A SEPARATE INFILTRATIVE SYSTEM (SEE BELOW). 6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS GREATER THAN 45° AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9. INSTALL 34NCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10. SITE PLAN INFORMATION FROM OTHERS, LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. X Item # DBox12, FRR6 & FRR12 GENERAL ABSORPTION AREA NOTES 12" SO. NYLOPLAST H-20 I. INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. SOLID COVER ASSEMBLY - REMOVABLE PVC CAP 2. ABSORPTION TRENCHES SHALL BE T WIDE OR LESS AND PARALLEL THE GROUND SURFACE CONTOURS. FLUSH WITH SURFACE PARALLELING TRENCHES SHALL BE SEPARATED BY A DISTANCE OF 6' MIN. 3. THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 24'X24"A` CONCRETE 4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT IN NARDSCAPE SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. _ - 5. NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER _ TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST INSTALL MARKER IF CAP IS TO FINISH GRADE OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR BE BURIED. GROUNDWATER IS ENCOUNTERED IN THE OVER -EXCAVATION. - 7. TOPSOIL COVER MAY BE VARIED (1-FDOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING.j/ V MIN ?'MAX CIRCULAR IRRIGATION -STYLE VALVE BOX & COVER - LID COLOR PURPLE 4"0 PVC RISER OR GREEN - LABEL "SEWER" FILL FINISHED GROUND - MAINTAIN POSITIVE CO PVC TWO-WAY SLOPE AWAY FROM TOP SURFACE OF STANDARD INSPECTION PORT, TYP. (4"0 CLEANOUT TEE THE CHAMBER TRENCHES. PVC SOLID PIPE CUT TO FIT. LOCATE PER 17 PLAN VIEW. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. FLOW f FILL 4"0 SEWER LINE \ \ I%MIN IN LANSCAPE S \ I /\ PVC COUPLING FOR SUPPORT Two -Way Cleanout \ 37 Scale. !J.Tfl. P (MIN.) Gravelless Chamber Absorption Trench Scale: N.T.S. FORATED PVC PIPE. PIPE TO REST ON OF THE BED MAINTENANCE NOTES. 1. TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE DINTS SYSTEM, THE OWNER SHALL CONSIDERTHE FOLLOWING: I.A. MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B, MINIMIZE SOLIDS GOING DOWN THE DRAIN. I.C. ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D. MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1E. USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F. KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G. AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H. DO NOT USE LYE -BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN -OFF, OR OTHER STRONG CLEANING AGENTS. ' 1.1. DO NOT PUT ANY "ROOT DETERRENTS' DOWN THE DRAIN, I.J. DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN I.K. MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2. THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION, THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. FRAL® Monster Distribution BOX • 12- Hole Distribution Box Quick & easy pipe seals secured with threaded nut. • New design allows parallel pipe runs on 4 sides. • Includes a threaded lid, gasket and security seal. REQUIRED REQUIRED ROTO•FLOW 4' - OR - POLYLOCK EQUALIZER 'VAVTOFF WER wrsvioemu"noe Nor ro sr<, c nrnxuu�neo worwoaave The FRALO Monster D-Box is engineered with U.V. resistant hig-density polyethylene and a gasketed watertight connection, This design offers ease of installation with outlets exiting in four directions. Sand, crushed stone or native material Undisturbed La VALLE&Y 10 Pipe 29.5" Access to Grade Required ptional Riser System 6or 12" Riser 2a' WMEW111111112iiVa. ii NLET Phone: 719-395-6764 ..a e =: www.valleyprecastiocim SITE EVALUATION 1. SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DERICJ. WALTER, PE MICHAEL A. BERRY, PE BOUNDARIES UNLIMITED INC. HUDDLESTON-BERRY 923 COOPER AVE., STE. 201 2789 RIVERSIDE PARKWAY GLENWOOD SPRINGS, CO 81601 GRAND JUNCTION, CO 81501 970.945.5252 970.255.8005 2. EVALUATION DATE(S): MARCH 7, 2023. 3. SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER (HUDDLESTON-BERRY (PROJECT #02614-0001, MARCH7, 2023) AS USDA SANDY LEAN CLAY WITH GRAVEL AND COBBLES; TYPE 3; WITH AN LTAR OF 0.35 GPD/SF. 4, SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=750 GPD: 4,A. SPRING, WELL OR POTABLE CISTERN=100' 4.B. POTABLE WATER SUPPLY LINE=25' 4.C. STRUCTURE W/ BASEMEN/CRAWL SPACE=29 4.D. STRUCTURE W/O BASEMENT/CRAWL SPACE=10' 4.E, PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH =10' 4.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 4.G. LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 4.H. DRY GULCH, CUT BANK OR FILL AREA=25' 4.1. SEPTIC TANK=5' 4.J. RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A. SPRING, WELL OR POTABLE CISTERN=50' 3.B. POTABLE WATER SUPPLY LINE=19 3.C, STRUCTURE W/ BASEMENT/CRAWL SPACE=5' 3.D. STRUCTURE W/O BASEMENT/CRAWL SPACE=5' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH =10' 3.E INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE = 10' &G. LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND =50' 3.H. DRY GULCH,. CUT BANK OR FILL AREA=10' 3.1. STA TRENCHIBED, UNLINED SAND FILTER OR SEEPAGE PIT=5' 4. HORIZONTAL INFLUENCE AREA(S)(WQCD, WQSA-6): 4.A. THE NEAREST ADJACENT SEPTIC SYSTEM IS LOCATED APPROXIMATELY 150' EAST WITH A DESIGN CAPACITY (DC) OF 450 gpd 4.A.A. MINIMUM HORIZONTAL INFLUENCE AREA: D=100+{(11.5"DC}-1000)/1001'8 D=100 + { Q1.5 `4501-1000) 11001 ' 8 = 74' D<150'. THEREFORE THE PROPOSED SYSTEM WILL NOT IMPACT THE NEAREST ADJACENT SEPTIC SYSTEM. SURFACE \ \ \ T PS\I \ \ N.\ \ \ \------------- ------------- ------------ ------------- tl ° __ SANDY LEAN CLAY WIT GRAVEL AND COBBLES, BROWN, MOIST, STIFF-- _ _ - _ _ Site & Soils Evaluation Scale: N.T.S. Item 0 1500 Gallon Top Seam - 2CP DESIGN NOTES • Design per performance. test per ASTM c1227 • Top surface area 62.33 ft' • Pc ® 28 days; concrete = 6,000 PSI Min. Installation: • Tank to be set on 5" min. sand bed or pea gravel • Tank to be backfLlled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet identified above pipe • Delivered complete with internal piping • 4' Maximum bury depth F_7.!l ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0'-0. 3' 0" V0" 3' - 0" 2'- V 4' 0" 3' - 0" 4' - 0" DRY 4' - 0" NOTE: HIGH DENSITY POLYETHYLENE TANKS BY NORWESCO, INC. ARE AN ACCEPTABLE ALTERNATIVE TO CONCRETE. 7 C FUMS tD Grass PVC TEE/RISER F "" '"nl" Ln WITH EFFLUENT FILTER ON THE m TANK OUTLET Top View 8"lard Section View Digging Specs Invert Dimensions i Net Capacity Net Weight 13' Long . 8' Wide Inlet Outlet I Length Width Height Inlet Side Outlet Total Lid Tank Total_ 56" below inlet 1 56" 53" i 132" 68" 68" 1002 gal 507 gal 1509 gal 3600 Ibs 11180 Ibs 14780 Ibs WDO Ve: 719-395-6764 ALLEY Fax:�719395-3727 PRECAST, Inc. Webill www.valleyprecastcom Buena ;Vista, Colorado Email: frontdeek@valieyprecastoom BOUNDARIES UNLIMITEDiNc. CIVIL ENGINEERING, LAND SURVEYING E BEYOND 923 Cooper Avenue, Ste.201 Glenwood Springs, CO 81601 tele:970.945,5252 www.bu-inc.com Engineer or Surveyor Seal LIEF 0\ N11VJ' V:oQ 9/10/25 T� Q • 37110 s/ONALE Client Information: CUC Construction, Inc. 625 Aiipart Rd. Glenwood Springs, CO 81601 Subsurface Utility Engineering (SUE) Required Project: No If "Yes", SUE Certification by: Firm: NIA Job #: NIA Date: NIA NORTH C 20' 40' Scale: 1" _ 20' Know whars below. Call before you dig. v) F� E W i too.) ® a) o �0 U = C •O w, O - L16 O w f� asCM L N a 4O"+ N a d N C r proval Comments: Date Revision LE o.: Sheet Designer: Col . -.1 _ .... r,-.:-�ransreci.nur�srrrc'x r:.xiaux..r•nmrv:.�r