Loading...
HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF P ERMIT BLRE-0 8-25-9439 Eustolia Valadez and Jose Leon New Single-family dwelling w/ attached garage TBD Rapids View Lane, New Castle Rapids On The Colorado, Lot 6 - 218104307006 1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATIONAL RESIDENTIAL CODE (l.R.C.)AND 2018 I NTERNATIONAL EN ERGY CONSERVATION CODE (I,E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS", NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERTOR LIGHTING TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL I NFORMATION. 6) OPEN HOLE SOILS REPORT tS REOUTRED AT FOOTTNG INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 2,000 PSF soil bearing. 7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF FRAME INSPECTION. 8) FLOODPLAIN ELEVATION CERTIFICATE: A FLOODPLAIN ELEVATION CERTIFICATE, SEALED BY COLORADO PROFESSIONAL LICENSED SURVEYOR, IS REOUIRED PRIOR TO FRAME INSPECTION. THIS CERTIFICATE SHALL VERIFY THAT FINISH FLOOR ELEVATION IS A MINIMUM OF 12 INCHES ABOVE FLOODPLAIN ELEVATION. 9) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, lS REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFIELD COUNTY'S 25-FT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE & BUILDING HEIGHT GUIDE STAPLED TO ISSUED PLANS. 10) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE oF OCCUPANCY PROVIDE FINAL APPROVAYSIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH DEPT. 1 1 ) BLOWER DOOR TEST tS REOU|RED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD COUNry COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 12) pRESCRtpTtVE PATH USTNG 2018 tECC TABLE R402.1.2 lS CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE.HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET. $ { l{- "\ \ ?tlq