HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF P ERMIT
BLRE-0 8-25-9439
Eustolia Valadez and Jose Leon
New Single-family dwelling w/ attached garage
TBD Rapids View Lane, New Castle
Rapids On The Colorado, Lot 6 - 218104307006
1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATIONAL RESIDENTIAL CODE (l.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE (I,E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS", NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERTOR LIGHTING TO BE DOWNCAST AND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL I NFORMATION.
6) OPEN HOLE SOILS REPORT tS REOUTRED AT FOOTTNG INSPECTION AND PRIOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
2,000 PSF soil bearing.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
8) FLOODPLAIN ELEVATION CERTIFICATE: A FLOODPLAIN ELEVATION CERTIFICATE, SEALED BY
COLORADO PROFESSIONAL LICENSED SURVEYOR, IS REOUIRED PRIOR TO FRAME INSPECTION. THIS
CERTIFICATE SHALL VERIFY THAT FINISH FLOOR ELEVATION IS A MINIMUM OF 12 INCHES ABOVE
FLOODPLAIN ELEVATION.
9) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, lS
REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFIELD
COUNTY'S 25-FT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE &
BUILDING HEIGHT GUIDE STAPLED TO ISSUED PLANS.
10) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE oF
OCCUPANCY PROVIDE FINAL APPROVAYSIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
1 1 ) BLOWER DOOR TEST tS REOU|RED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD
COUNry COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
12) pRESCRtpTtVE PATH USTNG 2018 tECC TABLE R402.1.2 lS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE.
ALL NEW HOMES TO HAVE WHOLE.HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015
IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET.
$
{
l{-
"\
\