HomeMy WebLinkAboutComcheck ReportCOMcheck Software Version 4.L,5.5
Envelope Gompl iance Certificate
Project lnformation
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Vertical Glazing / Wall Area:
Construction Site:
Donegan Storm King Rd
Glenwood Springs, CO 81601
Additional Eff iciency Package(s)
Credits: 1.0 Required 1.0 Proposed
Reduced Lighting Power, 1.0 credit
Building Area
2018|ECC
Glenwood Springs bldg B1
Glenwood Springs, Colorado
5b
New Construction
4/"
Owner/Agent:
Dan Kunau
Citadel Self Storage
502 572 7880
dkunau@andovermgt.com
Designer/Contractor:
Sally Kaufman
Kaufman Design Group, inc
941.5 E Harry St #405
Wichita, KS 67207
316-6L8-0448
sally@kdginc.co
Floor Area
1 -Warehouse : Nonresidential 1 0000
Envelope Assemblies
Assembly Gross Area Cavity
or R-Value
Perimeter
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factort"l
Roof 1: Other Metal Building Roof, [Bldg. Use 1 - Warehouse] (b)
Floor 1: Slab-On-Grade:Unheated, [Bldg. Use 1 - Warehouse] (d)
NORTH
Exterior Wall 4: Steel-Framed, 24" o.c., [Bldg. Use 1 - Warehouse]
Door 2: Other Door, Garage door 14/" glazing, [Bldg. Use 'l -
Warehousel
Door 3: lnsulated Metal, Swinging, [Bldg. Use 1 - Warehouse]
EAST
Exterior Wall 1 : Steel-Framed,24" o.c., [Bldg. Use 1 - Warehouse]
Window 1: Other Window:Operable, Pert. Specs.: Product lD Guardian
Sunguard SN68 on Crystalgray#2, SHGC 0.30, PF 0.38, VT 0.48, [Bldg
Usel-Warehousel (c)
SOUTH
Exterior Wall 3: Steel-Framed,24" o.c., [Bldg. Use 1 - Warehouse]
Window 3: Other Window:Operable, Perf. Specs.: Product lD Sunguard
SN68 on Crystalgray#2, SHGC 0.30, PF 0.89, VT 0.48, [Bldg. Use 1 -
Warehousel (c)
WEST
Exterior Wall 2: Steel-Framed,24" o.c., [Bldg. Use 1 - Warehouse]
Window 2: Other Window:Operable, Perf. Specs.: Product lD Sunguard
SN68 on Crystalgreay #2, SHGC 0.30, PF 0.38, VT 0.48, [Bldg. Use 1 -
1 0000
700
5990
2520
2't0
887
31
5125
420
887
31
13.5 9.0
0.037
0.730
0.054
0.290
0.210
0.054
0.290
0.054
0.290
0.054
0.290
0.035
0.540
0.064
0.310
0.370
13.5 9.0
13.5 9.0
0.064
0.450
13.5
0.064
0.450
0.064
0.450
Project Title:
Data filename
Glenwood Springs bldg 81 Report date
S:\Projects\AndoverMgmt\GlenwoodSpringsCO\SiteBGarages\comcheck\Glenwood_Springs_Bld1 Page
B1.cck
09l04l25
1of 10
Assembly Gross Area Cavity
or R-Value
Perimeter
Gont.
R-Value
Proposed
U-Factor
Budget U-
Factorr"l
Warehousel (c)
(a) tsudget U{actors are used tor software basehne calculations ONLY, and are not code requirements.
(b) 'Othe/ components require supporling documentation for proposed U-factors.
(c) Fenestration product performance must be certitied in accordance with NFRC and requires supporting documentation.
(d) Slab-On-Grade proposed and budget U-factors shown in table are F{actors.
Envelope Gompliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory
requirements listed in the lnspection Checklist.
Sally Kaufman-architect Sa/24- Karz/,naz,9-4-2025
Envelope PASSES: Design 47" better than code
Name - Title Signature 6/ U Date
Project Title:
Data filename
Glenwood Springs bldg 81 Report date
S:\Projects\AndoverMgmt\GlenwoodSpringsCO\SiteBGarages\comcheck\Glenwood_Springs_Bldt Page
BL.cck
09l04l25
2of 10
COMch eck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project lnformation
Energy Code:
Project Title:
Project Type:
201"8 rEcc
Glenwood Springs bldg B1
New Construction
Owner/Agent:
Dan Kunau
Citadel Self Storage
502 572 7880
dkunau@andovermgt.com
Designer/Contractor:
Sally Kaufman
Kaufman Design Group, inc
941-5 E Harry St #405
Wichita, KS 67207
316-618-0448
sally@kdginc.co
Construction Site:
Donegan Storm King Rd
Glenwood Springs, CO 8L601
Additional Efficiency Package(s)
Credits: 1-.0 Required 1.0 Proposed
Reduced Lighting Power, 1.0 credit
Allowed lnterior Lighting Power
A
Area Category
B
Floor Area
(ft2)
c
Allowed
Watts / ft2
D
Allowed
Watts
1-Warehouse l_0000 o.43 4320
Total Allowed Watts = 4320
Proposed lnterior Lighting Power
A
Fixture lD : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
CDE
# of Fixture (C X D)
Fixture Watt.
1-Warehouse
LED: P1-: 8' STRIP PENDANT: LED Linear 33W
LED: SL: 8'STRIP SURFACE: LED Linear 33W
3200
1
Total Proposed Watts = 3840
lnterior Lighting Compliance
Statement
Compliance SfatemenL The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2018 IECC requirements in COMcheckVersion COMcheckWeb and to comply with any applicable
mandatory requirements listed in the lnspection Checklist.
lfarren R. Law, Electrical Engineer eh*"EE- 9/5/25
ame -e Signature Date
1 64
64
50
10 640
Project Title: Glenwood Springs bldg 81
Data filename:
Report date: 09/05/25
Page 1 of 6
COMcheck Software Version COMcheckWeb
Exterior Lighting Compliance Certificate
Project lnformation
Fnergy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
Donegan Storm King Rd
Glenwood Springs, CO 81601
Allowed Exterior Lighting Power
A
Area/Surface Category
2018 tEcc
Glenwood Springs bldg B1
New Construction
2 (Light industrial area with limited nighttime use (LZ2))
Owner/Agent:
Dan Kunau
Citadel Self Storage
502 572 7880
dkunau@andovermgt.com
Designer/Contractor:
Sally Kaufman
Kaufman Design Group, inc.
94L5 E Harry St #405
Wichita, K56l2Ol
316-618-0448
sally@kdginc.co
B
Quantity
c
Allowed
Watts /
DE
Tradable Allowed WattsWattage (B X C)
580 (Walkway < 10 feet wide)692 ft of 0.5 Yes 346
Total Tradable Watts (a) = 346
Total Allowed Watts = 346
Total Allowed Supplemental Watts (b) = 400
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b) A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable
a reas/surfaces.
Proposed Exterior Lighting Power
A
Fixture lD : Description / Lamp / Wattage Per Lamp / Ballast
580 (Walkway < L0 feet wide. 692 ft of walkway length): Tradable Wattage
LED: N1: WALL PACK: LED A Lamp 25W:
LED: KL: CANOPY DOWNLIGHT: LED A Lamp 9W:
B
Lamps/
Fixture
CD
# of Fixture
Fixture Watt.
E(cxD)
1
1
25
10 9
1-8 450
90
TotalTradable Proposed Watts = 540
Exterior g ng Compliance
Statement
Compliance Sfatement: The proposed exteriorlighting design represented in this document is consistentwith the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 201-8 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the lnspection Checklist.
llaruen R. Law, Electrical Engineer h-h*zE-e/s/2s
xterior Lighl.ing PASSES: Desigrr 2891' better than code
SignatureName - Title Date
ProjectTitle: Glenwood Springs bldg 81
Data filename:
Report date: 09/05/25
Page 2 of 6
COMch eck Software Version COMcheckWeb
Mechanical Gompliance Certificate
Project lnformation
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Construction Site:
Donegan Storm King Rd
Glenwood Springs, CO 81601
Additional Efficiency Package(s)
20r.8 tEcc
Glenwood Springs bldg B1
Glenwood Springs, Colorado
sb
New Construction
Owner/Agent:
Dan Kunau
Citadel Self Storage
502 572 7880
dkunau@andovermgt.com
Designer/Contractor:
Sally Kaufman
Kaufman Design Group, inc.
9415 E Harry St #405
Wichita, KS 67207
316-618-0448
sally@kdginc.co
9t4t25
Credits: 1,0 Required 1.0 Proposed
Reduced Lighting Power, 1.0 credit
Mechanical Systems List
QuantitySystem Type & Description
l-0 HVAC System (Single Zone):
Heating: 1 each - Central Furnace, Gas, Capacity = 60 kBtu/h
Proposed Efficiency = 81.00% Et, Required Efficiency: 80.00 % Et or 80% AFUE
Cooling: 1 each - Single Package Vertical AC Unit, Capacity = 23 kBtu/h, Air-Cooled Condenser, Unknown Economizer
Proposed Efficiency = 13.40 EER, Required Efficiency = 9.00 EER
Proposed Part Load Efficiency = 0.00 , Required Part Load Efficiency = 0.00
Fan System: FAN SYSTEM 1-- Compliance (Motor nameplate HP and fan efficiency method) : Passes
Fans:
FAN 1 Supply, Constant Volume, 790 CFM, 0.5 motor nameplate hp, 0.0 fan efficiency grade, 0.0 total fan
efficiency,0.0 design fan efficiency, fan exception: Single fan <= 5HP
Water Heater:
Electric Storage Water Heater, Capacity: 30 gallons
No minimum efficiency requirement applies
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the lnspection Checklist.
1
Warren H. Clements - Mech PEOR
t' ,t'' t.t:(tF \
a
Name - Title Signature Date
Project Title: Glenwood Springs bldg B1
Data filename:
Report date: 09/09/25
Page L of 9