HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLCO-09-25-9466 CITABEL GLENWOOD LLC SELF-STORAGE BUI LDING B'1 267 CENTER DRIVE COOPER SUBDIVISION, WEST GLENWOOD 1) SEPARATE PERMtTS ARE REQUTRED FOR TENANT FINISH CONSTRUCTION 2) THE APPROVED PLANS ARE TO BE ON-SITE FOR INSPECTIONS 3) SANTTARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS 4) A L|ST OF REQUTRED |NSPECTTONS W|LL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. HTTPS :/AAAAAI/. COLORADO.GOV/PAC I F RA/DPO ELECTRICAL PLUMBING P ERMITS 5) UNDERGROUND UTtLtTy LOCATES lS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE. 6) ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 7) SEPARATE SIGN PERMITS ARE REQUIRED FOR ANY EXTERNAL SIGNS. PLEASE SEE THE COUNTY'S WEBSITE FOR THE APPLICATION. 8) ELECTRTCAL CODE COMPLTANCE W|LL BE DETERMINED BASED ON FIELD tNSPECT|ONS PERFORMED By THE STATE ELECTRICAL INSPECTOR, (303) 869- 3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 9) THE ELECTRTCAL CODE REQUTRES A SEPARATE ELECTRICAL PERMIT FOR LOW VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN tNSPECT|ON W|TH THE STATE ELECTRTCAL TNSPECTOR rS REQUTRED (303) 869- 3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTION. 1O) THE FIRE SPRINKLER AND ALARM ARE REQUIRED TO BE INSPECTED AND APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP DRAWINGS TO THE FIRE DISTRICT FOR REVIEWAND SCHEDULE THE INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION IS APPROVED. 1 1) ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO BACKFILLING. 12) PLEASE PROVTDE SPECTAL TNSPECTTONS REPORTS TO THE BUILDING DEPARTMENT AS SPECIFIED WITHIN THE GENERAL NOTES OF THE STRUCTURAL DRAWINGS. 13)ALL EXTERTOR L|GHT|NG lS TO BE DOWNCASTAND SHTELDED 14)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE CONSTRUCTION WILL BE REQUIRED TO BE FIRE-STOPPED WITH LISTED FIRE STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE ASSEMBLTES AT THE FRAMTNG TNSPECTION. (tBC 713) 15)A KNOX BOX tS REQUTRED TO BE MOUNTED ON THE BUTLDTNG. PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION. 16) IF THE FIRE SPRINKLER SYSTEM REQUIRES A FIRE PUMP. THEN THE UTILITY ROOiVi THAT HOUSES THE PUi\riP VviLL BE REQiiiRED TO BE ONE-HOUR coNSTRUCTtON. (rBC TABLE 508.2.5) 17)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GR|P, TNCLUD|NG POCKET AND SLTDTNG DOORS. (ANS| 4117.1 - 404.2.6) 18)AN AtR LEAKAGE TEST tS REQUTRED PRIOR TO PERFORMING THE FINAL BUTLDTNG TNSPECTTON. (rECC C4025) 19) NATURAL GAS IS 2PSI SYSTEM, REGULATORS ARE REQUIREDAT EACH APPLIANCE. 20)THE FLUSH HANDLES FOR THE WATER CLOSETS ARE TO BE ON THE ACCESSIBLE SIDE OF THE FIXTURE. SOME MAY REQUIRE RIGHT HAND FLUSH MODELS. 21) DOORS WITH DOUBLE KEYED DEAD BOLTS TO HAVE A SIGN POSTED: 'THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED' 22)THE STRUCTURAL DRAWTNGS TNDTCATE THE CANOPTES DESTGN tS PENDTNG. PLEASE SUBMIT ENGINEER STAMPED DRAWINGS PRIOR TO CONSTRUCTING THE CANOPIES. 23) THE WATER HEATERS SHOWN MOUNTED ON THE WALL INSIDE THE STORAGE SPACE ARE TO BE 6'ABOVE THE FLOOR OR VEHICLE PROTECTION WLL BE REQUIRED.