HomeMy WebLinkAboutApplicationGarfield Counfi;
Community Development Department'' ' " 108 8th street, Suite 401
Glenwood Springs, CO 81601
l970l s4s-82r2
: www.garfieldcountyco.gov
TYPE OF CONSTRUCTION
(4
BUILDING PERMIT
APPLICATION
Commercial/Multi-Fa mily Demolition
Manufactured Home or Tinv Home (Sinele or Multi-Level)
I:Reroof
FEET
Residential F, Duplex or
Dwel Unit
SINGLE FAMILY HOME
- MAXIMUM SIZE OF
Address: 8 Oakview Terrace, Swedesboro, NJ 08085
INVOLVED PARTIES
4721831
Emait Addresr. sjz26@comcast.net
856Phone:Property owner: Stephen & Jennifer Zanetich
Mailing
Mailing Address:
Email Address:
Address: PO Box 1031, Glenwood Springs, CO 81002
contractor: To Be Determined
Architect: Brad Jordan/Jordan Architecture 6186690
Emait Addresr. bradjordanarchitect@g mail.com
Phone:
970Phone:
Mailing
Emait Addresr. steve@mountaintowncg.com
Phone:(206 r9107766
Mailing Address: PO Box 1577, Basalt, CO 81621
Engineer:Steve Edmiston/MTCG
Mailing Address: _
Email Address:
Phone:
PROJECT DETAIIS
Manufactured Home lnstaller: N/A
Describework. NEW SINGLE FAMILy RESIDENCE
robAddress: TBD MOUNTAIN SPRINGS RANCH ROAD
sub. NONE
425357.O8 39.62 AC
21',Height:# of Floors .1
Assessor,s parcel Number: 218528200033
Property Size (5q. Ft. or Acres):
toa Parcel A Block_
Owne/s Valuation
Sq. Ft. of Building:
of Work:
3243_5
,/Class of Work:New Remodel/Alteration Addition
{Garage:Attached Detached
nutnoiitV. This application for a Building Permit must be signed by the Owner of the property, described above,
or an authorized agent. lf the signature below is not that of the Owner, a separate letter of authority, signed by
PROJECT DETAITS CONTINUED
' Septic:unity
Type of Heat:Natural Gas Propane Electric Other
Permit #:
-
the Owner, must be provided with this Application.
i Lesal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
i purposes of inspections by the Building Division.
: Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement'
CERTIFICATION
I hereby certify that I have read this Application and that the information contained above is true and correct. I
understand that the Building Division accepts the Application, along with the plans and specifications and other data
submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness
of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as
Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln
consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any
federal, state, or local law regulating the work and the Garfield County Building Code, OWTS regulations and
applicable land use regulations (eounty Regulation(s)). All County development requiring a permit, except for
residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building
Permit may be suspendecl or revokpd, uprrn notice frorn the County, if the location, construction or use of the
I structure(s) and facility(ies), described above, are not in compliance with County Regulation{s) or any other
: applicable law.
I I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring
the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the
i structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this
r Application, including submittals, and inspections of the work by the Building Division do not constitute an
i acceptance of responsibility or liability by the County of errors, omissions, or discrepancies. As the Owner, I
; acknowledge that responsibility for compllance with federal, state and local laws and County Regulations rest with
, me and my authorized agents, including without limitation my architect designer, engineer and/ or builder.
I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have
provided the required information which to the my
Zr^*..e-
best of
GI lo a
Property Ourner Print Date
OFFICIAL USE ONLY
Special Conditions:
76 Manu. Home Fee:Misc. Fees:
RIFEEP 70V
Total Fees 5g Eala qt qq@
Setbacks:OCC Group:c C-onst.&
surLDrNG / PIANN|NG DtVtStON :to- I
Signed Approval Date
,t?l^
ENERGY COM PLIANCE SHEET REQUIREM ENTS:
Effective June 30, 2023 Please provide details showing how building complies / meets Garfield County's
adopted 20'18 IECC and 9!i@E-@95,
Depict and show outline the structure's building thermal envelope. Outline should clearly show portions
of the building to be conditioned inside the envelope (and label or othenuise identify any areas remaining
unconditioned outside this envelope)
Energy Compliance Plan should further include:
Chosen Energy Compliance Path. Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value
and U-Values to comply with IRC Table R4O2.1.2r U-Factor Alternative: Provide a ResCheck Reportr Total U-Factor Alternative: Provide software generated submittal design reports and inspection
checklist for any RESNET ERI index or other performance path designs
Air sealing details around openings, pipes, penetrations, joints
Fenestration U-factors
Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel
types, locations
Energy efficient lighting specifications - 90% to be high-efficacy (LED complies)
Manual J Report required for new building structures and new equipment installations.
STRUCTURAL PLANS: Please provide the following information on the structural plans.. SOILS REPORT - lf the projecl is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a boilsieport, then a
copy of the soils report is required to submit a building permit application.o Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.o Foundation plan showing complete footing and foundation dimensions.r Footillg and foundation details specifying reinforcement and referenced on plans.
' Framilg plans for each floor level and roof. All beams, columns, joists, rafters and trussesspecified. Pre-manufactured structures require the engineers stamp, signature and date.' Framing /connection details, bracecl wall lines, shear wall schedule, locltion and hold downs.
owner print: ..-J d'{, Wi#*' 7aL,udc h*t'liu lzi
NOTE:. lf any required information is missing, delays in issuing the permit are to be expected. lfdetermined by the Building Official that additional information ii necessary to review thb applicationandior plans for compliance, the application may be placed on hold until tire required information isprovided. work may not proceed without the issuance of a permit
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, aswell as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the ownerto act as their representative.
Building cannot be occupied until a certificate ol occupancy (co) is issued. using the building without aCo will be consideredan illegal occupancy and may ob grolnos ior vacating the premises. (Final/COinspection requirements wilr be attached t6 your apirove-c fietd set or pLns.i ' -
I hereby acknowledge I have read, understand and will abide by the requirements of thischecklist.
-itepvls n 'Z<'te*l.h Sign:
G{ro1er
Garfield CounQ
BUILDING DEPARTMENT
108 Eiqhth Street, Suite 401, Glenwood Springs, CO 87601
Tel: (970) 94s-8212
PLAN REVIEW CHECK LIST
Permit Not 9LRF0q-25-q460 Zone{,i)
Building lssues Planning/Zoning lssues (s
Engineered Foundation
Driveway Permit
Surveyed Site Plan
Grade/ Topography 30%
Attach Residential Plan Review List
Subdivision Plat Notes
Fire Department Review
Valuation Determination/ Fees
Property Line Setbacks
35 ft. Stream Setbacks
Flood Plain
Buirdins neientZS'*oV
zonrng 5rgn-ufi
Road lmpact Fees 6, E,>,
Gradel TopographY 40%
Planning lssues
Subdivision Plat
ion &m
?
q
,fLt
qID {"?,kK:k"*qkl
Red Line Plans/ Stamps/ Sticker{?tdler q-g-2nre
Attach Conditions
ry&Jz
Rlr €Ja,P #z 7o=
^HEpbyE-vlilanr
Energy Compliance Path/Plan Received .
kecd KevrsF> to4-zazq
Plan Reviewer to Sign Application FlrS /380 x thf, q5
6L
e4l
102,N
51,00
D n
Parcel/Schedule No
40# Snowload Letter - Manuf
Soils Report
CIPFN"l*CI1f; S0lL$ ttfi rr(][ q'r
t$ R[Q[,llREil A'f- f{,}{"]'i"lrutul
z+/4 7b6,
00
?
lot ?08,*
aljueb
VA
I i[.l$pri]T'l0N z,Q--Q ";''ur
( c+np,rEport /fan/s//,t/fril.)
/ uoildtnq
luah'oit
Ig
# ? n)O??,'o