HomeMy WebLinkAboutConditions of PermitBLRE-09-25-9460
STEPHEN & JENNIFER ZANETICH
New 2,380 sq ft Single-family dwelling w/ attached 1,326 sq ft garage
TBD Mountain Springs Ranch Rd, GWS
Mountain Springs Ranch, Parcel A - 218528200033
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2018
I NTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERTOR LTGHTTNG TO BE DOWNCAST AND SHTELDED
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNITY DEVELOPMENT WEBSITE FOR
ADDITIONAL INFORMATION.
6) OPEN HOLE SOrLS REPORT tS REOUTRED AT FOOTTNG TNSPECTTON AND PR|OR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
2,000 PSF soil bearing. lnclude compaction report for structural fill.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR BUTLDTNG TNSPECTOR AT TrME OF
FRAME INSPECTION.
8) VERTFy REOUTREMENTS AND COORDTNATE TNSPECTTONS OF ELEVATOR W|TH NORTHWEST
COLORADO COUNCIL OF GOVERNMENTS (NWCCOG) ELEVATOR INSPECTION PROGRAM. PROVIDE
FINAL ELEVATOR SIGN-OFF / APPROVAL AT FINAL BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY.
9) DUMBWAITER EOUTPMENT, SHAFT & DOORS TO BE TNSTALLED ACCORDTNG TO PRODUCT',CUT
SHEETS'AND DETAILS STAPLED TO FIELD COPY.
1O) PROPANE FUEL ryPE - SEE ATTACHED PROPANE GUIDE.
11) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSTONAL LTCENSED SURVEYOR, lS
REQUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH
GARFIELD COUNTY'S 2'.FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE
DEVELOPMENT CODE. BUILDING HEIGHT GUIDE PROVIDED FOR REFERENCE.
12) ADDITTONAL DRTVEWAY TMPROVEMENT BY JOHN PLANO, CHrEF BUTLDTNG OFFTCTAL AND
ROBIN PITT, FIRE MARSHAL GLENWOOD SPRINGS FIRE DEPTTO BE COMPLETED PRIOR TO
CERTI FICATE OF OCCU PANCY.
13) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAUSIG.N-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
14) BLOWER DOOR TEST tS REOU|RED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFTELD
COUNry COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
15) PRESCR|PIVE PATH USrNG RESCHECK rS CHOSEN FOR ENERGY COMPLTANCE OF THIS HOME.
MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-HOUSE
MECHANICALVENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2) SHOWN ON
COVER SHEET.
16) SUpply',cATE CODE'WHEN CALLTNG rN ALL FUTURE TNSPECTTONS TO ENSURE GARFIELD
COUNTY BUILDING INSPECTOR HAS ACCESS TO PREMISES ON REOUESTED INSPECTION
DATES. THANKYOU.
,Q.
rt
N