HomeMy WebLinkAboutElevator SpecsHoistway Doors lncluded
27
21
-/2
Hoistway
Cab
\N
o)
.='6
O6
ocoFF
oo
tL
fi€
i+ *E
o=
(s
E
.9o+rNtlo
.9,c
iL
N
6
GrF>
6F-5NF
X 1%"Sheetrock inside and
outside hoistway
Center Line
2xl2Planks
between 2x4 studs
2x4 construction
S
N
CY)
o
o
J
ocN
-C #-o)O O()0)i
I.oicglXo(uxg>#
Approved By
Door may be at floor level
if machine room or an
overhead motor is used.
20"
nside
22%"
Opening
N
s
IN(o
-c
O=Tz.
8No
o
oJ
22-%',W
x32-/i'r
R/O to
lnstall
Controller
.$
Door lnterlock 5-
Access
Elevotion I n novotion I n c
ECONO.LIFT 1 OO DUMBWAITER
DOORS - SAME SIDE
20"Wx20"Dx30"H
100lb. Capacity
HOISTWAY: The hoistway must be in accordance with "Safety Code for Elevators and
Escalators" (ASME A17.1) and all state and local codes.
PLUMB HOISTWAY: Due to close running clearances owner/agent must ensure that
hoistway is plumb, and square and is in accordance with dimensions on these drawings.
REINFORCED WALL: The rail wall must be reinforced with double 2x12 planks as shown
in the drawings. The machine and rail system requires these 2x12 planks for support.
MACHINE ROOM: Machine room may be located within the hoistway on the bottom floor
or in a closet adjacent to the hoistway (behind the rail wall). The machine room must have
a lockable access door. This door must remained locked at all times.
POWER SUPPLY: A lockable fused disconnect must be provided in accordance with local
electrical codes. The supply must be a 115V, 20A dedicated circuit.
DOORS: Doors must meet local fire code. lnterlock devices are provided and must be
mounted to doors as directed in the installation guide. Hoistway doors included.
Roll Up Gate
Level 1,2 &Access = LH
1 Hour Corridor Assembly
2 Hour Corridor Assembly
Shaft Wall - AER-09038
DATE:
IINITED STATES GYPSUM .OMPAlvY
SCALE:
Ths Sbn wdU ebil mu$ mr bc ud
wihul d 6ql.te €v'lMdon by 6c ovrcle eiF pdf<ioMl
b v.d& & ndhbiliry ol thc d6is for s Biv.n .hEn'rc.
IUSTIMER
(sEE DRAWING ND" 1000-501 FIR SETTIIN ELEVATI0N "A-A" )
A
J/
TLEAR HOISTWAY
STABILIZING
RILLERS
OEUBLE 2XI2
-IENTEREO NN IAR16"
33-t14"
CLEAR
HI]ISTUAY
I]NUBLE 2X6
-IENTERED [N tAR 7-u4"
GUIDE
RAIL
AREA
ItALL
THIIKNESS-l
DOIR
A
AttEss
DNNR
swrNc
Compliant with all current ASME A17.1 & CSA 844 Code
t7-U4"
2
4
IAR
I
R
28"
IAR
l/4
6ATE
JIB NA}'IE SHIP Tt]
DATE
APPR!VED
TITLE: Inteli-Lift Pro 250 28x28x28 Same Side with Bi-parting Gate & Swing Doors
SHEET I Elevotion Innovotion nc
SPETIAL REEUIREMENTS
DRIVE TYPE: |{INDING DRUl'l
RATED SPEED: 30 FPM
IINTRILLER MIDELI INTELI-LIFT
P0IYER: 1l5V 20AMP
HOISTWAY TO BE BUILT BEFERE OUMBTIAITER IS INSTALLEO
EXIEPT THE WALLS ARE TO BE IMITTED WHERE HOISTTAY
DII]RS OTTUR UNTIL THE I]UMBYIAITER IS INSTALLED &
HI]ISTVAY DI]ERS ARE SET IN PLAIE
AttEss
t]EER
tAR
EATE
JAMB MIUNTED 24V GEN-II KEYPAO
WITH IN USE ANO IAR HERE LIGHTS
H[ISTWAY
DEORS
ST0PS: 2 D<IIN-LINE EoPP
IPENINGS:_ 2 _ e LIWER, UPPER
IRAVEL:_I.8.0. RATED L[A0: 250 LBS
REV
REVISIINS
ITHER
G.A.L. TYPE 'SN" DNER L[tK
DESIRIPTII]N
I ln HR, tyL 'B
PLAIN STEEL
SL I DE-UP
BI-PARTING
PLAIN STEEL
NBN-PLUGABLE INTERLNK
EI'IEREENtY RELEASE
I IN HR UL "B' LABEL
FUSIBLE LINK
STAINLESS SILLS
FLINR LIANING
SWING
BI -PARTING
NONE / BY ITHERS
STAINLESS STEEL - #4
BY EII
IOLLAPSIBLE
STAINLESS STEEL - f4
TOUNTER LIADING
STAINLESS STEEL - #4
PLAIN STEEL - PRIMED
MASINRY IBNSTRUTTIIN
DRYWALL T[]NSTRUITINN
DATE BY
SHEET 2DATE L.O
APPROVEtj
DATE REfi
BYOATEREVoE$RrPIId{
TITLE: 0utBtArTER SECIroN ELEVA1rot{ .A-A.
SHIP TD
SEE PA6E I
Jt]B
6
JZ
-
a
-9
i
E
6EJI
e
J
E3
E
z
v
EJ
e
Hq
BJL
tr
EJ
e.
dB{
JE
6-
-9ll!4=
<[E
Ru
<zo
UE-
-JE
6-
o
q