Compliance Certificate
Project lnformation
Project Title:
Energy Code:
Location:
Construction Type:
Project Type:
Project Sub Type:
Orientation:
Conditioned Floor Area
Glazing Area:
Climate Zone:
Project No:
All Electric:
ls Renewable:
Has Battery:
Has Charger:
Has Heat Pump
Construction Site:
TBD MOUNTAIN SPRINGS MNCH ROAD
GLENWOOD SPRINGS , Colorado 81601-
Project Notes:
ZANETICH RESIDENCE
2018 |ECC
Garfield, Colorado
Single Family
New Construction
None
Bldg. faces 180 deg. from North
23At ftz
I8o/o
sb (8499 HDD)
1704059
false
true
false
true
true
Owner/Agent:
BRAD jordan
po box 1031
jordan architecture inc.
glenwood springs , CO 81602
97061-86690
BRADJORDANARCH ITECT@GMAIL. COM
Designer/Contractor:
brad jordan
po box 1031
jordan a rchitecture inc.
glenwood springs , CO 81602
9706186690
BMDJ ORDANARCH ITECT@G MAIL.COM
\
N
.{tt
$
s
Report Title: ZANETICH RESIDENCE Report Date: 1,019125, 7:52 AM lof12
Envelope Assemblies
Assembly Gross Area or
Perlmeter
Prop.
U.
Factor/
F-Factor
Req.U- Prop.Factor/ UA
F-Factor
Cavity
R-Value
Cont.
R-Value
Req.
UA
Celling: Raised or Energy
Truss
Floor: Slab-On-Grade
(Unheated)
lnsulation depth: 3.00'
lnsulation position: Vertical
lnsulation
Wall: Wood Frame, L6" o.c.
Orientation: Front
Window: Wood Frame
Orientation: Front
Door: Solid Door (under
50% glazing)
Orientation: Front
Door l.: Glass Door (over
507o glazing)
Orientation: Front
Wall L: Wood Frame, 16"
o,c.
Orientation: Right side
Window L: Wood Frame
Orientation: Right side
Door 2: Glass Door (over
50% glazing)
Orientation: Right side
Wall 2: Wood Frame, 16"
o.c,
Orientation: Back
Window 2: Wood Frame
Orientation: Back
Wall 3: Wood Frame, 16"
o.c,
Orientation: Left side
Window 3: Wood Frame
Orientation: Left side
Door 3: Glass Door (over
50% glazing)
Orientation: Left side
Basement Wall: Solid
Concrete or Masonry
Orientation: Back
Wall height: 10.00
lnsulation depth: 10.00'
lnsulation position:
lntegral lnsulation
Basement Wall 1: Solid
Concrete or Masonry
Orlentatlon: Left slde
Wall height: 10,00
lnsulation depth: 10.00'
lnsulation position:
lnfedrrl ln<illefi^n
tsasement Wall 2: Solid
Concrete or Masonry
Orien[al-ion: RighL side
Wall height: L0.00
Insulation depth: 10.00'
lnsulation position:
lntegral lnsulation
1813
180
49.0
20.0
20.0
20.0
20.0
19.0
19.0
19.0
0.0
10.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
0.020
0.51.0
0.042
0.260
0.1-50
0.300
0.042
0.260
0.300
o.o42
0.260
0.042
0.260
0.300
0.028
0.028
0.028
0.026
0.540
36 47
0 0
1"326
79
276
48
866
182
t44
254
35
730
32
40
630
0.060
0.300
0.300
0.300
0.060
0.300
0.300
0.060
0.300
0.060
0.300
0.300
0.050
59
24
65
L4
32
55
43
13
11
40
t0
T2
32
4T
2L
32
T4
23
47
43
9
9
28
8
1"2
1"8
9
4
16315
136
0.050
0.050 7
Cnmplianre: PassFs using UA trade-crff
Report Title: ZANETICH RESIDENCE Report Date: 1019125, 7:52 AM 2ot12
Max UA: 48O Your UA: 354Compliance: 26,27. Better Than Code
The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. lt DOES
NoT provide an estimate of energy use or cost relative to a minimum-code home,
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REscheck. Each slab-on-grade
assembly in the specified climate zone must meetthe minimum energy code insulation R-value and depth requirements.
Compliance Statement
The proposed building design described here is consistent with the building plans, specifications, and other calculations
submitted with the permit application. The proposed buildinq has been designed to meetthe 2018 IECC requirements in
REscheck-Web and to comply with the mandatory requirements listed in the REscheck lnspection Checklist.
Name - Title Signature Date
Report Title: ZANETICH RESIDENCE Report Date: LOl9l25, 7:52 AM 3ofL2
lnspection Checklist
Energy Code: 2018 IECC
Requirements: 0olo w€r€ addressed directly in the RESCheCk software
Text in the 'rcomments/Assumptlong" column is provided by the user in the REScheck Requlrements screen. For each
requirement, the user certlfies that a code requirement will be met and how that is documented, or that an exception is being
claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Pre-lnspection/Plan Review
Additional Comments/Assumptionsr
FgJriffi SCflEilFqD. FEU.taw .eo$!$llft?Qorn"mrrw:ApEq|tr]p:$png,
103.1,
103.2
IPRUl
Construction drawinos and
documentation dem6nstrate
energy code compliance for the
buildino envelone. Thermal
enveloIe repreiented on
construction documents.
I complies
l-'l Does Not
comply
f-l Not
b6servable
1-l Not
hdplicable
103.1,
103.2,
403.7
lPR3ll
Construction drawinos and
documentation dem6nstrate
energy code compliance for
liohtino and mechanical
sVstemls. Svstems servino
niultiple dvielling units m-ust
demonstrate comoliance with
the IECC Commertial Provisions.
! Complies
1--l Does Not
C-omplyll Not
b6servable
f-l Not
AEplicable
Heatino and coolino eouioment
is sizedperACCA Manial S
based on loads calculated per
ACCA Manual I or other methods
approved by the code official.
Heatino:
Btu/hr -
I---I
Cooling:
Heatino:
Btu/hr -n
Cooling:
Btu/hrr-l
! Complies
a'l Does Not
C6mply
f--'l Not
bdservable
[-l Not
A-pplicable
L Hioh lmoact {Tier L)Medium lmoact ffier 2)3 Low lmDact (Tier 3)
Repott Title: ZANETICH RESIDENCE Report Date: IOl9l25, 7:52 AM 4of12
Foundation lnspection
Section#
6r Req.lD Foundation Inspection : Value
PlansVerified FieldVerified
value Complies?CommentslAssumptlons
303.2.1
lFo11l2
403.9
IFOI2IZ
A Drotective coverino is
initalled to protect e-xposed
exterior insulation and extends
a minimum of 6 in. below qrade.
Snow- and ice-meltino svstem
controls installed.
I
I Complies
l-l Does Not
C6mply
T-l Not
bdservable
n Not
Hpplicable
402.1.2
lFo3ll
Additional Comments/Assumptions:
f] Complies
T-l Does Not
Comply
[-l Not
O6servable
Tl Not
hdplicable
See the EnveloDe
Assemblies tatile for
values
I Heated
nunheated
n Heated
u
lJnheated
402.L.2
lFo1ll
Slab edge insulation R-value.
I Complies
f-l Does Not
Comply
f-l Not
bdservable
T] Not
Hpplicable
ft ft ! Complies
l--l Does Not
bdmpty
Tl Not
bdservable
flNot
Applicable
see the Enveloae
Assemblies tatile for
values
Slab edoe insulation
depth/le-nqth.
See the EnveloDe
Assemblies tatile for
values
I Complies
T-] Does Not
Comply
T-l Not
bdservable
Tl Not
Hplicable
402.t.L
lFo4l1
Conditioned basement wall
insulation R-value. Where
interior insulation is used,
verification mav need to occur
durinq lnsulaticin lnspection. Not
required in warm-humid
lorations in Climate Zone 3.
I Complies
Tl Does Not
Comply
Tl Not
bdservarle
r fl Not
'A-pplicable
Conditioned basement wall
insulation installed per
manufacturer's instructions.
303.2
lFo5lr
ft ft f l Complies
l---l Does Not
Comply
Tl Not
d6servable
al Not
h-pplicable
See the Envelone
Assemblies tatile for
values
402.2.9
lFo6l1
Conditioned basement wall
insulation depth of burial or
distance from top of wall.
1 Hiqh lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmoact (Tier 3)
Report Title: ZANETICH RESIDENCE Report Date: 1019125, 7:52 AM 5of12
Framing / Rough-ln lnspection
sesg
e:Rqflr'u'-'
- Flbtr$
ViTIf,fiL. :' lYclg**'i:6ampfiqrr.', :eornmeinen*prr,nnpu'irrr
402.1.1,
402.3.4
IFRUl
Door U-factor.I Complies
l--l Does Not
t6mply
f-l Not
b6servable
f-l Not
Fpplicable
see the Envelope
Assemblies tatile for
values
402.1.1,
402.3,L,
402,3.3,
402.5
lFRzlt
Glazing U-factor (area-weighted
averagel.! Complies
1--l Does Not
bdmpty
l-l Not
dbservable
fl Not
hdplicable
See the Envelope
Assemblies table for
values
402,4,L.L
lFR23l1
Air barrier and thermal barrierlnstalled per manufacturer's
instructions.
n Complies
Tl Does Not
C6mply
1-l Not
U6servable
f-l Not
Hplicablc
402.4.3
lFR20l1
Fenestration that ls not site built
is listed and labeled as meeting
AAMA A/VDMA/CSA
I0]-ll.S.2lA44O or has infiltration
rates per NFRC 400 that do not
exceed code limits.
I ComPlies
f-l Does Not
b6mply
Tl Not
b5servable
f-l Not
Xdplicable
lC-rated recessed liohtino
fixtures sealed at -
houslng/lnterlor flnlsh and
labeled to indicate =2.0 cfm
leakase at 75 Pa,
IComplies
O Does Not
Comply
Tl Not
dbservable
n Not
Xiplicable
403.3.1
lFR12l1
Suoolv and return ducts in attics
insulated >= R-8 where duct is>= 3 inches in diameter and>= R-6 where < 3 inches.
Supply and return ducts in other
portions of the building
insulated >= R-6 for diameter>= 3 inches and R-4.2 for < 3
inches in diameter,
I Complies
Tl Does Not
LOmpry
n Not
b6servable
Tl Not
Xiplicable
403.3.2
lFRl3ll
Ducts, air handlers and filter
boxes are sealed withjoints/seams compliant with
lnternational Mechanical Code
or lnternational Residential
Code, as applicable.
! Complies
['l Does Not
C6mply
Tl Not
b6servable
Tl Not
A-pplicable
40ts;3.5
IFR{.$]}
Building cavities are not used as
ducts or plenums,I Complies
I I Uoes Not
Edmply
n Not
bbservable
l--l Not
hfrplicable
Report Title: ZANETICH RESIDENC E Report Date: 1019125, 7:52 AM 6of12
Section
1a #
Req.lD
403.3.7
lFR28l3
403.4
lFR17l'
403,4,1
lFR24l1
403.5.3
lFR18l'
403.6
lFR19l'
. PIansFraminglRough-ln' Verifiedlns-pCctiori i Value
Field
Verifiedvalue Complies?Comments/Assumptions
Ducts declared to be within the
conditioned space are either 1)
comoletelv within the
continuoui air barrier and within
the building thermal envelope,
2) buried within ceiling
insulation in accordance with
Section R403.3.6 and the air
handler is located completelY
within the continuous air barrier
and within the building thermal
envelope and the duct leakage
is <= 1.5 cfm / L00 square feet
of conditioned floor ar'ea served
by the duct system, or 3) the
ceilino insulation R-value
installed aqainst and above the
insulated duct >= to the
proposed ceiling insulation R-
value, less the R-value of the
insulation on the duct,
HVAC oioino convevino fluids
above'1b5 dF or chilled fluids
fl Complies
f_l Does Not
bdmptv
Tl Not
b6servable
l--l Not
Hplicable
fl Complies
f"l Does Not
C6mply
f"-l Not
bdservable
f-l Not
Lpplicable
, f] Complies'n Does Not
Comply
a-.l Not
[Tdserva ble
fl Not
Applicable
l_J Complies
[-l Does Not
b6mply
Tt Not
b6serva ble
| "l Not
hdplicanle
f] Complies
i--l Does Not
Hmpty
f_l Not
dtrservable
f"l Not
h-dplicable
below 55 sF are insulated to >R-
3.
Protection of insulation on HVAC
piping.
!ffa_{u,".
pipes are insulated to
Automatic or oravitv dampers
are installed o-n all outdocir air
intakes and exhausts.
303.1.
lFR4l1
U-factors of fenestration
nroducts are determined in
bccordance with the NFRC test
procedure or taken from the
default table.
I Complies
r--l Does Not
Hmpty
il Not
d6servable
r"-'l Not
hiplicable
Additional Comments/Assumptions:
1"Hioh lmpact (Tier l-)2 Medium lmpact (Tier 2)3 Low lmoact (Tier 3)
Report Title: ZANETICH RESIDENCE Report Date: IOl9l25, 7:52 AM 7of12
lnsulation lnspectlon
Additional Comments/Assumptionsl
!r,t?!tyt! !!t lr"9t!r!41t Bqr.'., i rrlRt!!F.'. :
ltgt.rrJ!!$4lr/c
All installed insulation is labeled
or the installed R-values
provided.
! Complies
f-l Does Not
uompry
f-l Not
b6servable
f-l Not
Adplicable
llN3l1
402.1.1,
442.2.5,
402.2.6
Wall insulation R-value. lf this is
a mass wall with at least % of
the wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
u
DI
Wood
Mass
Steel
fl wood
C Mass
fl steel
f] complies
n Does Not
t6mply
l-l Not
b6servable
Tl Not
Xf,plicable
See the EnveroDe
Assemblies tatile for
values
303.2
ltN4ll
Wall insulation is installed oer
man ufacturer's instructionb.I Complies
f-l Does Not
Comply
Tl Not
dbservable
l-l Not
AFplicable
1 Hiqh lmDact (Tier 1)Medium lmpact fiier 2)Low lmpact (Tier 3)3r I
Report Title: ZANETICH RESIDENCE Report Date: '1,019125, 7:52 AM Bot12
Final lnspection Provisions
Section#
& Req.lD
403.r.2
lFl10l,
403.5.1
lFrl1l'
403.2
lFl26l,
403.5.1.1
lFr28l,
, 403.5.1.2
lFl2912
Plans
Verified
value
FieldVerified
Final lnspection Provisions
1
Heat pump thermostat installed
on heat pumps.
Circulatino service hot water
svstems hive automatic or
atcessible manual controls.
All mechanical ventilation
system fans not part of tested
and listed HVAC equipment
meet efficacv and air flow limits
perTable R403.6.1.
Hot water boilers supplying heat
throuqh one- or two-pipe
heating systems have outdoor
setback control to lower boiler
water temperature based on
outdoor temperature.
Heated water circulation
svstems have a circulation
pump. The system return pipe is
a dedicated return Dipe or a
cold water supply pipe. Gravity
and thermos-syphon circulation
svstems are not oresent.
Cbntrols for circr.ilating hot
water system pumps start the
oumo with sional for hot water
demand within the occupancy.
Controls automaticallv turn off
the DUmD when watei is in
circulation loop is at set-point
temperature and no demand for
hot water exists.
Electric heat trace svstems
complv with IEEE 515.1 or UL
5l-5. Controls a utomatically
adiust the enerov inDut to the
he'at tracinq to -niaintain the
desired water temperature in
the piping.
Value Complies?CommentslAssumptions
I Complies
L-l Does Not
Comply
f-l Not
bdservabl
lFt2sl,
6.403
f-l Not
h-dplicable
f l Complies
n Does Not
bdmptv
fl Not
bbservable
T-l Not
Hpplicable
I Complies
[-l Does Not
Comply
l*-l Not
d6servable
Tl Not
A[plicable
! Complies
n Does Not
Comply
f-l Not
bdservable
f"l Not
hiplicable
: f] Complies
r f:l Does Not
, Comply
t-- l Not
bdservable
n Not
Applicable
I Complies
T-l Does Not
Comply
T-l Not
bdservable
f"l Not
Applicable
Iwood
[_] steel
t:]n
Wood
Steel
I Complies
f'l Does Not
E6mply
l..l Not
b6servable
Tl Not
hiplicable
See the Envelope
Assemblies tatile for
values
402.L
402.2
.l-,
.1,
402.2.2,
402.2.6
lFt1ll
Ceiling insulation R-value.
ceilino insulation installed Der
manufacturer's instructions.
Blown insulation marked every T-l Does Not
Comply300 ft,fl Not
b6servabl e
H
L] complies
Not
plicable
303.1.1.1,
303.2
lrlzl'
Report Title: ZANETICH RESIDENCE Report Date: 1,019125, 7:52 AM 9ofL2
Fha f hrfi pitcrlon Frwl*io.lls
Flanr
Vc.fmddYtlrlb ':"itiiid&sri eornrri:*ritrirar$a d6ft iins
Demand recirculation water
systems have controls that
manage operation of the pump
and limit the temperature of the
water entering th'e cold water
piping to <= 104eF.
I Complies
T] Does Not
Edmply
fi Not
b6servable
[-l Not
AFplicable
Draln water heat recoverv unlts
tested in accordance with CSA
855.1, Potable water-side
pressure loss of drain water
heat recovery units < 3 psi for
individual units connected to
one or two showers, Potable
water-side pressure loss of drain
water heat recovery units < 2
osi for individual units
tonnected to three or more
showers.
I Complies
[*'] Does Not
Comply
T-l Not
b5servable
r-t Not
h'pplicable
404.1
lFt611
90% or more of oermanent
fixtures have hidh efficacy
lamps.
I Complies
n Does Not
t6mply
{--l Not
U6servable
Tl Not
hdplicable
40'4.1'1
lFiasll.
Fuel oas liohtino svstems have
no co-ntinu-ous pilot lisht.f] Complies
l-'l Does Not
LOmpry
Tl Not
bdservable
T-'l Not
hdplicable
Compliance certifi cate posted.fl Complies
Tl Does Not
C6mply
T-l Not
bdservable
[-l Not
A'pplicable
3109,i30
lFtLolp'
Manufacturer manuals for
mechanical and water heating
systems have been provided.
f] Complies
fl Does Not
C6mply
l-l Not
b6servable
T-l Not
A-riplicable
Vented attics with air permeable
lnsulation include baffl e
adjacent to soffit and eave
vents that extends over
insulation.
u Complies
l--l Does Not
LOmpry
Tl Not
b6servable
Tl Not
A-pplicable
402.2.4
lFl3l1
Attic access hatch and door
insulation >R-value of the
adjacent assembly.
I Complies
I I Does Not
C"nmnly
Tl Not
Ubservable
i-l Not
I[plicable
402.4.L,2
lFtlTll
Blower door test @ 50 Pa, <=5
ach in Climate Zones l-2, and<=3 ach in Climate Zones 3-8.
I Complies
n Does Not
C6mply
Tl Not
b6servable
Tl Not
A[plicable
Report Title: ZANETICH RESIDENCE Report Date: 1019125, 7:52 AM L0 of L2
Section
#
& Req.lD
Plans !. Verified
Final Inspection Provisions : Value Complies? iComments/Assumptions
Field
Verified
Value
! Complies
l--l Does Not
bdmpty
fl Not
bdservable
Tl Not
Aiplicable
cfm/100 ft2 cfm/100 ft2
403.3.3
lFt2711
Ducts are Dressure tested to
determine'air leakaqe with
either: Rough-in test: Total
leakaoe measured with a
oressire differential of 0.L inch
iv.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakaoe measured with a
nress[re differential of 0,1 inch
i,v,o, across the entire system
inCludino the manufacturer's air
ha ndler 6nclosu re.
cfm/100 ft2
Tl Complies
f-l Does Not
bdmptv
T-1 Not
bdservable
n Not
Xiplicable
clmtLOO ftz
403.3,4
lFl4l1
Duct tidhtness test result of
<=4 cfm/100 ft2 across the
svstem or <=3 cfm/L00 ft2
without air handler @ 25 Pa. For
rouqh-in tests, verification maY
need to occur during Framing
I nspecti on.
403.3.2.r
lFt24lt
Air handler leakaoe desiqnated
by manufactureret <=2n/o oI
design air flow.f_l Does Not
bdmpty
fl Not
bdservable
Tl Not
A[plicable
iI ComPlies
403.1.1
I IFl9]'
Additional Comments/Assumptions
Proorammable thermostats
inst-alled for control of primary
heating and cooling systems
and initiallv set bv manufacturer
to code specifications.
f] Complies
fl Does Not
C6mply
T-l Not
bdservable
n Not
hiplicable
1 Hiqh lmDact (Tier 1-)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Report Title: ZANETICH RESIDENCE Report Date: 1019125, 7:52 AM L1 of 12
2018 IECC Energy
Efficiency
Certificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Skylight
Heating System:
Cooling System:
Water Heater:
Namei
Comments:
26.OO
29.OO
10.oo
49.OO
o.26
o.15
o.oo
Date:
trsulatiorr R-Value
Glass & Door Rati U-Factor SHGC
Heati & Coolin EfficiencyEment
Signature
Report Title: ZANETICH RESIDENCE Report Date: IOl9l25, 7:52 AM 'J,2 of 12