HomeMy WebLinkAboutConditions of PermitCONDITIO NS OF PERMIT
BLRE-09-25-9 47 5
HEATHCOTE WEST, LLC
"GUEST CABIN 3'
New Single-Family Dwelling with attached carport / storage
TBD Sweetwater Ranch Rd, Gypsum
Heathcote West Tracts, Tract G-7 - 186335300131
PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY:
. THE WATER SYSTEM IS TO BE INSTALLED AND OPERATIONAL.
o THE MAIN ROAD, FUTURE ROAD 1 SHOWN ON THE VICINITY MAP, lS TO BE
COMPLETE.
. THE SPRINKLER AND ALARM SYSTEMS ARE TO BE APPROVED BY GYPSUM
FIRE.
. THE ELECTRICAL IS TO BE APPROVED BY THE STATE.
. THE SEPTIC IS TO BE APPROVED BY GARFIELD COUNTY ENVIRONMENTAL
HEALTH DEPARTMENT.
. ALL COUNTY BUILDING INSPECTIONS ARE TO BE APPROVED'
2 THE APPROVED PLANS ARE TO BE ON-SITE FOR INSPECTIONS
3 SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS
4 A LIST OF REQUIRED INSPECTIONS WLL BE ATTACHED TO THE PLANS. THE
STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
IJTTPS /AAtt/eot p a nn Gar\//panl trlc/n(1Fla/n PO EL tr(:TR rnar pt il[rFltNG ptr
\s
st\
a\
,\\
NRMITS
5 ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
tNSPECT|ONS PERFORMED By THE STATE ELECTRICAL INSPECTOR, (303) 869-
3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE
WRITTEN DOCUMENTATION OF THE INSPECTIONS.
6 THE FIRE SPRINKLER AND ALARM ARE REQUIRED TO BE INSPECTED AND
APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP
DRAWINGS TO THE FIRE DISTRICT FOR REVIEWAND SCHEDULE THE
INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE
INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN
THE FINAL INSPECTION IS APPROVED.
TEa / aft7
7 ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE
INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO
BACKFILLING.
8 UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE.
9 SMOKE DETECTOR LOCATIONS, CO DETECTOR LOCATIONS, HANDRAIL,
WINDOW DOOR EGRESS AND BATH EXHAUST FANS ARE TYPICAL RED-LINES ON
RESIDENTIAL PLANS.
1O SOILS REPORT REQUIRES 3'OF STRUCTURAL FILL BE PLACED UNDER THE
FOOTINGS. GEOTECHN]CAL ENGINEER'S REPRESENTATIVE TO OBSERVE THE
EXCAVATION, STRUCTURAL FILL PLACEMENT, AND PROVIDE A REPORT
VERIFYING THE ASSUMED 3OOOPSF IS BEING MET PRIOR TO A FOOTING
INSPECTION TO BE PERFORMED.
11 A BLOWER DOOR TEST AND POSSIBLY A DUCT BLASTING TEST REPORT IS
REQUIRED PRIOR TO FINAL INSPECTION. IT IS YOUR RESPONSIBILITY TO SET UP
THE APPROPRIATE INSPECTIONS WITH A RATER AND SUPPLY THE INSPECTOR
WITH THE REPORT. SEE ATTACHED GUIDE FOR SMALLER STRUCTURES.
13 CODE MINIMUM STATES THAT ALL HOT WATER PIPES %'AND LARGER ARE
REQUIRED TO BE INSULATED TO R-3 MINIMUM AND ALL HYDRONIC HEATING
PIPES ARE REQUIRED TO BE INSULATED TO R-3
15 ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED.
16 THE LOCATION OF THE CLOTHES DRYER COULD RESULT IN THE EXHAUST DUCT
BEING OVER THE ALLOWED 25" THEN SUBTRACTING FOR OFFSETS. THE CODE
REQUIRES THE DEVELOPED LENGTH TO BE PERMANENTLY MARKED. IF THE
DEVELOPED LENGTH IS OVER CODE, THEN THE INSTALLATION INSTRUCTIONS
FOR THE SPECIFIC DRYER IS TO BE ON-SITE DURING THE ROUGH-IN
INSPECTION.
17 THE ICE SHIELD IS TO BE INSTALLED AT THE EAVES TO A MINIMUM 24" UP FROM
THE INSULATED WALLS.
18 PROPANE FUEL TYPE SPECIFIED : SEE ENCLOSED GUIDE AND MEP ENGINEERED
STAMPED DETAILS
20 ALL SHOWER DOORS ARE REQUIRED TO MAINTAIN A MINIMUM 22'IN THE CLEAR
AND ARE REQUIRED TO SWING OUT.
21 ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY
A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO
ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
22 PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING
DEPARTMENT FOR BOLTING AND WELDING.
P zaf 3
24 NO TRAPS ON THE MECHANICAL ROOM FLOOR DRAINS. THESE 4' FLOOR DRAINS
ARE THE PROPANE DRAINS THAT TIE INTO THE STORM SEWER AND DAYLIGHTS.
26 OVERFLOW DRAINS REQUIRED ON FLAT ROOFS THAT DO NOT HAVE SCUPPERS
OR A METHOD OF OVERFLOW RELIEF.
27 PRESCRIPTIVE PATH USING 2O18IECC TABLE R402.1.2 CHOSEN FOR ENERGY
COMPLIANCE OF THIS HOME. STAMPED MEP DRAWINGS INCLUDED IN FIELD
COPY. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION
sysTEM TNSTALLED (2015 rRC TABLE M1507.3.3(1) AND (2) SHOWN ON COVER
SHEET.
Psrfs