HomeMy WebLinkAboutApplicationGarfield County D7
ili
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601i' (9zol94s-s212
www.earfield -countv.comj{;i ' ut '}t,!'tr,
( , {,:
(,'i 1, .' ,Com *iidfr tia l/M u lt i - F a m i Demolition
PARTIES
Property Owner:Louise Marron pr,one, {970 \443-2015
Mailing Address: 4804 County Road 127, Glenwood Springs, CO 81601 -9275
Email Addres.. lamarron 421 @hotmail. com
contractor: Dylan Walters Phone:970 366-8127
Mailing Address 807 COUNTY ROAD 237, Silt, CO 81652
Emait Address. rockymtnbuilder@gmail.com
Architect: Armstrong Steel Phone:72A 5504591
Mailing Address:2 lnverness Dr E, Ste 200,Englewood, CO 80112
Email Address:cassie.c@armstron gsteel. com, pr@armstrongsteel. com
Engineer:Will Lupher phone,{970 )510-0773
Mailing Address:1040 Main St, Carbondale, CO 81623
Emait Addresr. will@evolvestruct.com
Manufactured Home lnstaller:Phone: ( )
Mailing Address:
Email Address:
I
e or Multi-Leve
Reroof
Accessorv Dwelling Unit ) - MAXTMUM S|ZE OF 1,200 SQUARE FEET
Manufactured Home or Ti Home
Residential (SF, Duplex or Townhome)
PROJECT DETAITS
Describe Work: 30' X 40' Metal Building {purchased from Armstrong Steel Buildings)
will be erected to the north of our house for use as a garage/shop, N O €lectf lO. N
rob Address, 4804 County Road 1 27, Glei$bod:$p$ngs, CQffi SO:t,,.
Assessor'sparcet Number: 219519100140 t$B ni,q.,i.. Ir...-.*..1rtu6. Mountain Springs Ranch tot 7
Owne/s Valuation of Work:r 100,000 Property Size (Sq. Ft, or Acresl:
5q. Ft. of Building:1,2AA Height:16'5*fl of Floors 1
Class of Work:aaaition
o plurrbrS
Garage:Attached
Remodel/Alteration
Detached
35+
I pnotecr osrar$ coNTTNUED
Septic:
Type of Heat:
Driveway
Permit:
NOTICE
Natural Gas Propane
Community
Electric
Permit #
Other
Authoritv. ThisapplicationforaBuildingPermitmustbesignedbytheOwneroftheproperty,describedabove,
or an authorized agent. lf the signature below is not that of the Owner, a separate letter of authority, signed by
the Owner, must be provided with this Application.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
i3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICATION
l
i I hereby certify that I have read this Application and that the information contained above is true and correct. I
i understand that the Building Division accepts the Application, along with the plans and specifications and other data
I submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness
i of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as
Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln
consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any
federal, state or local law regulating the work and the Garfield County Building Code, OWTS regulations and
applicable lancl r-tse regLrlations {County Regulation{s)). All County derlelopment requiring a permit, except for'
residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building
Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the
structure{s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other
applicable law.
I hereby grant permission to the Building Division to enter the property, described aborre, to inspect the work. I
further acknowledge that the issuance of the Building Permit does not prevent the Building official from: {1) requiring
the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the
structureis) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this
Application, including submittals, and inspections of the work by the Building Division do not constitute an
acceptance of responsibility or liability by the County of errors, omissions, or disoepancies. As the Owner, I
acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with
me and my authorized agents, including without limitation my architect designer, engineer and/ or builder.
I hereby acknowledge that I have read and the Notice and Certification above, as well as, have
ts to the best of my knowledge.
Property Owner Print and Sign
provlded the required information/Loq-p< ftarrD+/
h-.$OFFICIAL UsE ONLY
.ffi a#a ctwdl fuN b / TIO /i/-g
Special Conditions:
A li..-+^J lr-1,,-+i^-.AUtUStCU YdtUdttutt.4K.ma. ca *qiYvr 'w:tr:66 m"i'ffi*.''"'
Misc. Fees:
'""f,"iLg,tb Fees Paid:
$rln t^ 5t Balance Due'-.tbaz.te #fie-qLffil OWTS No:
tJ ln
Setfacks:
*e'P
OCC Group:fBL ,""t .Irp, L,zorp!:
BUILDING / PLANNIN6 D]VISION (]il,/|n*/,
Signeci Approvai Date
to-z
ENERGY COMPLIANCE SHEET REQUIREMENTS:
Effective June 30, 2023 Please provide details showing how building complies I meets Garfield County's
adopted 2018 IECC and Climate Zone 5.
Depict and show outline the structure's building thermal envelope. Outline should clearly show portions
of the building to be conditioned inside the envelope (and label or othenruise identifu any areas remaining
unconditioned outside this envelope)
Energy Compliance Plan should further include:
Chosen Energy Compliance Path. Prescriptive: Cross Sections of insulated assemblies including the selected materiall R-Value
and U-Values to comply with IRC Table R4O2.1.2. U-Factor Alternative: Provide a ResCheck Report. Total U-Factor Alternative: Provide software generated submittal design reports and inspection
checklist for any RESNET ERI index or other performance path designs
Air sealing details around openings, pipes, penetrations, joints
Fenestration U-factors
Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel
types, locations
Energy efficient lighting specifications - 90% to be high-efficacy (LED complies)
ManualJ Report required for new building structures and new equipment installations.
STRUCTURAL PLANS: Please provide the following information on the structural plans.. SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a soils report, then a
copy of the soils report is required to submit a building permit application.. Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.r Foundation plan showing complete footing and foundation dimensions.r Footing and foundation details specifying reinforcement and referenced on plans.r Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.. Framing iconnection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Building Officialthat additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold untilthe required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a PIan Review fee at time of application submittal. The permit fee, as
well as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
Owner Print:Lo u,". / a,^ro n Sign Date:
!eB?43404
RESIDENTIAL ENERGY EFFICIENCY
R402.1.1 Vapor retarder. Wall assemblies in the bzild-
ing thermal em,elope shall comply with the vapor retalder
requirements of Section F.7O2.7 of the Internqtional Resi-
dential Code ar Section 1404.3 of the International Build-
ing Code, as applicablc.
R402,1.2 Insulation and fenestration criteria. The
building thermal envelope shall meet the requirements of
Table R402.1.2, based on the climate ?ofle specitied in
Chapter 3.
R402.1.3 R-value computation. Insulation rnaterial used
in layers, such as framing cavity insulation or continuous
R-30
insulation, shall be summed to compute the corresponding
corxponent R-value. The manufacturer's settled R-value
shall be used fbr blown-in insulation. Cornputed R-values
shall not. include an R-value for other building rnaterials or
air films. Whcrc insulated siding is used for the purpose of
complying with the continuous insulation requirernents of
Table R402.1-2, the manufacturer's labeled R-value for
the insulated siding shall be reduced by R-0.6.
R402.1.4 U-lactor alternative. An assernbly with a U-fac-
tor equal to or less than that specified in Table R402.1.4
shall be an alternative to the R-value in Table R402.1.2.
I
TABLE R4O2.1 .2
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT"
NR = Not Required.
For SI: I foot = 304.8 mm.
a, R-values are minimums. {,r-factors and SHGC are rnaximums. Where insulation is installed in a cavity that is less (han the label or design thiclmess of the
insulation, the installed /?-value of rhe insnlation shall be not less than the,l?-value specified in the table.
b. The fenestration U-factor column exchdes skylights- The SHGC column applies ro all glazed fene.stlation.
Exception: In Cliurate Zones I through 3, skylights shall be permitted to be excluded from glazed fenestradon SHGC requit'emenls provided that the SHGC
for such skylights does not exceed 0.30.
c. "10/l3"meansR-l0continuousinsulationorrtheinteriororexteriorofthehomeorR-l3cavityinsulationontheinteriorofthebasementwall-
" 15/19" means R-15 conthruous insulation on the interior or exterior of the home or R- 19 cavity insulation at the interior of the basemenr wall- .Altematively,
home.
d, R-5 insulation shall be provided unrler the full slab area of a heated slab in addition to the required slab edge insulation R-value for slabs- as indicated iu the
table. The siab edge insulation fbr heated slabs shall not be required to extend below the slab.
e. 'fhere re no SHGC requilements in the Mrine Zone.
t-. Ba,sernentwallinsulationisnotrequiredinwarm.hurnidlocationsasdefinedbyF'igureR30l.landTableR30l.l.
g. Altematively, insulation sulTicient to lill the l}arning cavity and providing not less than an J?-value ofR-19.
lr. The first value is cavity insulation, the second value is continuous insulation. Therefore. as an example, "l3+5" means R-13 cavity insulation plus R-5
continuous insulatiorr.
i. Mass walls shall be in accordance with Section R402.2.5, The second R*value applies where more than half of the insulation is on the interior of the mass wall-
TABLE R4O2.1.4
EOUIVALENT UfACTORS"
a. Nonfenestralion U-factors shall be obtained from measulernent, calculation or an approved source.
b. Mass walls shall be in aecordance with Section R402.2.5. Where more than half the insulation is on the interior, the ma.ss wall U-factors shall not exceed 0. I 7
in Clirnate Zone I,0.14 in ClimateZcne2,0.l2 in Climate Zone 3.0.087 in Climate Zone 4 except Marine,0.065 in Climate Zone 5 and Marine 4" and 0.05?
ir Clirnate Zones 6 thlough 8.
c. ftr warm-humid locations as defined by Figure R30 I . I and Table R30l . i , thc basernent wall U-{hctor shall not exceed 0.360.
2018 INTERNATIONAL ENERGY CONSERVATION CODE6
CoDright 6 zor T ICC. ALL RIGHTS RESER\4D. Ac.cssrd bylohn PImo 0plio@drbondalcco.ncr), (TlM of hbondalc) O!d$ Nubcr 3 ruu78as m AUB rr. "ue oz 13 ,{U {PDT) pusust to
IS A VIOI,ATION OFT}TETIDERAL COFYRICHT ACf AND THE LTCINSI,1GREtrMENT. AND SUBIECT TO CM AND CRIMN,{LPTNiLTIIS THDRTUIDER'
CLIMATE
ZONE
FENESTRATION
tlFACTORb
SKYLIGHTb
U+ACTOR
GLAZED
FENESTRATION
sHGCb'"
CEILING
BVALUE
wooD
FRAME WALL
F.VALUE
MASS
WALL
B.VALUEI
FLOOR
R.VALUE
BASEMENT"
WALL
fFVALUE
SLABd
B-VALUE
A DEPTH
GITAWL
SPACE"
WALL
R.VALUE
I NR 0.75 0.25 30 13 3t4 ll 0 {J 0
1 0.40 0.65 u.25 3E l3 4lb IJ o 0 0
3 0.32 u.55 tJ.z5 -38 20 or' 13+5"8/1-1 19 slt3'0 5113
4 except
Marine 0.32 0.55 0.40 49 20 or l3+5h 8lL3 r9 l0 /13 10, 2 ft r0/13
5 and
Marine 4 0.30 0.55 NR 49 20 or l3+5h t3lt7 30s r5lr9 r0,2 ft l5/19
6 0.30 u.55 NR 49 20+5" or l3+t0"ttlzu 30t t5l L9 10.4 ft t5Jt9
7and8 0,30 0.55 NR 49 20+5'or 13+10"t9lzt 388 t5l L9 lU,4 tt l5/19
CLIMATE
ZONE
FENESTFATION
UfACTOR
SKYLIGHT
U.FACTOF
CEILING
U.FACTOR
FRAME
WALL
U-FACTOR
MASS WALL
ufAcToRb
FLOOR
U.FACTOR
BASEMENT
WALL
U+ACTOR
CRAWL
SPACE WALL
UfACTOR
1 n.50 0.75 0.03.5 0.084 o.197 0.064 0.360 0.477
2 0.40 0.65 0.03t)0.084 0.165 0.064 0.360 0.477
3 0.32 0.55 0.030 0.060 0.098 o.047 0,091'0.i36
4 except Marine 0.32 0.55 0.026 0.060 0"098 o.o47 0.059 0.065
5 and Marine 4 0.30 0.5-5 o_026 0-060 0.082 0.033 0.050 0.055
6 0.30 0.55 o.026 0.045 0.060 0.033 o.050 0.055
7 .urd I 0.30 0.55 o.026 0.045 0.05?0.028 0.050 0.055
Gurfield C*uwtpt
BUILDING DEPARTMENT
108 Eighth Street, Suite 401, Glenwood Springs, CO 8160L
Tel: (970) 94s-8212
PLAN REVIEW CHE CKLIST
B*t-oF-Ag-ftfu/Permit No:
Building lssues Planning/Zoning lssues
c
l{l Fqgg43gUfi&"r Afi $;.fi{.}l'Nc
,ff m-22-26
Driveway Permit
Surveyed Site Plan
Septic Permlt and Setbacks
Grade/ Topography 30%
Attach Residential Plan Rev'iew List
Subdivision Plat Notes
Fire Department Review
Valuation Determination/ Fees
Red Line Plans/ Stamps/ Sticker
Attach Conditions
Application Signed
Energy Compliance Path/Plan Received
Plan Reviewer to Sign APPlication
Parcel/ Schedule No.
40# Snowload Letter - Manuf. Homes
Soils Report
$;{itL$ Rffi$}0r.{T
rty Line Setbacks
35 ft. Stream Setbacks
ood Plain
'Bui'iciing 'Heig'ht
Zoning Sign-Off
Rcad lrnpact Fees
Grade/ Topography 40%
Planning lssues
Subdivision Plat
Descri Dtion & Su mmarv:
ruoy #14=/$mO,ea
artshltuHg
ua/uafiu