HomeMy WebLinkAboutEngineer's OWTS Design Plan Geo Quest Project No. 25-143 Date: 9/9/25 Jaime Covarrubio 578 Canyon Creek Drive Glenwood Springs, CO (909) 538-4399 jaime_0910@hotmail.com RE: Onsite Wastewater Treatment System (OWTS) Soil EvaluaƟon Dear Mr. Covarrubio, Geo Quest was asked to perform a soil evaluaƟon for a new OWTS at the property described as:  Garfield County Parcel 217711102002  86 NaƟve Springs Drive, Rifle, Colorado This memo presents the evaluaƟon details and USDA soil type encountered at the property on Monday, September 1, 2025. This informaƟon may be used in OWTS design. Soil EvaluaƟon Two soil profile test pits, idenƟfied as Test Pit 1 (TP-1) and TP-2, were excavated near the north east corner of the property, near the proposed OWTS site. The excavaƟons were completed with a Bobcat mini excavator to maximum depths of 8 feet below ground surface and approxi- mate locaƟons are shown on the aƩached Test Pit LocaƟon Map. RepresentaƟve soil samples were collected from the material layers encountered in the test pits. These samples were evaluated and classified using the USDA Soil Texture and Structure methods. The USDA classificaƟons were applied to the guidance document from Colorado De- partment of Public Health & Environment, RegulaƟon No. 43, Table 10-1 as presented below. The soil was very moist below 5 feet with saturated soil and ground water encountered in the test pits at a depth of 7 feet. Table 10-1 - Soil Treatment Area Long-Term Acceptance Rates Soil Type Soil Tex- ture Soil Struc- ture-Type Soil Struc- ture-Grade PercolaƟon Rate (MPI) Treatment Level 1 2A Sandy Loam Granular Structureless 26-40 0.50 Respecƞully submiƩed, Geo Quest, LLC Kevin E. Dye, P.E. Figures: Boring LocaƟon Map, Logs Approximate Test Pit LocaƟon map 9/9/25 TP-1 TP-2 Proposed OWTS Site PROPOSED BARN/SHOP PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E EX. SHED W 1 0 0 ' S B 1 0 0 ' S B 100 ' S B 10 0 ' S B 10 0 ' S B 1 0 0 ' S B 1 0 0 ' S B 10 0 ' S B 100'SB 100'SB 100 ' S B 10 0 ' S B 10 0 ' S B 100' WELL SETBACK WELL OP E N D I T C H INSTALL 1000-GALLON TWO-COMPARTMENT SEPTIC TANK WITH AN EFFLUENT FILTER IN THE OUTLET RISER (SEE SETBACK NOTES) C/O TP TP APPROX. TEST PIT LOCATION, TYP. APPROX. TEST PIT LOCATION, TYP. INSTALL A TWO-WAY CLEANOUT OUTSIDE THE BUILDING 52 Q U I C K 4 I N F I L T R A T O R ( 4 x 1 3 ) OR 4 4 A D S A R C 3 6 U N I T S ( 4 x 1 1 ) BO T T O M O F B E D T O B E L E V E L ) 20' MIN. FROM FOUND. ≥50' FROM DITCH 5' MIN. FROM FOUNDATION 5' MIN. FROM FOUNDATION >10' FROM PROPERTY LINE INSPECTION PORT AT EACH END OF EACH LATERAL, TYP. NOTES: PROPERTY LINES ARE BEYOND THE MAPPED AREA. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. GEOTECHNICAL ENGINEER TO CONFIRM SOIL PROFILE AT THE CONSTRUCTED LOCATION PRIOR TO INSTALLING THE CHAMBER UNITS.EX. BARNEX. HORSE RIDING SHELTER EX. GRAVEL DRIVE EX . G R A V E L D R I V E EX. COVERED STORAGE (NO FOUNDATION) 37110DERIC J O N WA L T E R COL O R A D O LICE N S E D P R O F E SSIONA L E N G INEER 9/22/25 00 30'60' Scale: 1" = 30' NORTH 923 Cooper Avenue, Ste. 201 Glenwood Springs, CO 81601 tele: 970.945.5252 www.bu-inc.com Engineer or Surveyor Seal Sheet Client Information: Project No.: Filename: Designer: Drafter: Date: N: \ P R O J E C T S \ 2 0 2 5 \ 2 5 0 3 1 - 8 6 N a t i v e S p r i n g s - O W T S \ d w g \ 2 5 0 3 1 - V - T o p o . d w g 9/ 2 2 / 2 0 2 5 4 : 2 9 P M Subsurface Utility Engineering (SUE) Required Project: If "Yes", SUE Certification by: Firm: Job #: Date: Agency Approval Agency: Dept: By: Date: Comments: RevisionDate 9/22/25 RTC DJW 25031-v-topo.dwg 25031 909.538.4399 GLENWOOD SPRINGS, CO 81601 578 CANYON CREEK DR. JAIME COVARRUBIO GA R F I E L D C O U T Y , C O L O R A D O On s i t e W a s t e w a t e r T r e a t m e n t S y s t e m ( O W T S ) 86 N A T I V E S P R I N G S C.1 NO N/A N/A N/A SURFACE 12" 8' ± 5' ± MAINTENANCE NOTES 1.TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: 1.A.MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B.MINIMIZE SOLIDS GOING DOWN THE DRAIN. 1.C.ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D.MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E.USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F.KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G.AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H.DO NOT USE LYE-BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN-OFF, OR OTHER STRONG CLEANING AGENTS. 1.I.DO NOT PUT ANY “ROOT DETERRENTS” DOWN THE DRAIN. 1.J.DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN 1.K.MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2.THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. 86 Native Springs County of Garfield, State of Colorado Parcel No: 2177-111-02-002 I-70 Vicinity Map Rifle SITE ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. FINISH GRADE 4"Ø PVC RISER 4"Ø PVC TWO-WAY CLEANOUT TEE 4"Ø SEWER LINE 12" SQ. NYLOPLAST H-20 SOLID COVER ASSEMBLY REMOVABLE PVC CAP FLUSH WITH SURFACE 24"x24"x6" CONCRETE IN LANSCAPE IN HARDSCAPE To Silt TOPSOIL SANDY LOAM (SAND, SILT, CLAY, BROWN, MOIST) INCREASING MOISTURE BELOW 5' NOTES: THIS PLAN SET IS INTENDED TO BE PLOTTED IN COLOR. FAILURE TO DO SO MAY RESULT IN MISSING DATA & INFORMATION CRITICAL TO THE PROJECT. SITE EVALUATION 1.SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DERIC J. WALTER, PE KEVIN DYE, PE BOUNDARIES UNLIMITED INC.GEO QUEST 923 COOPER AVE., STE. 201 PO BOX 1372 GLENWOOD SPRINGS, CO 81601 RIFLE, COLORADO 81650 970.945.5252 970.318.6784 2.EVALUATION DATE(S): SEPTEMBER 1, 2025. 3.SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER (GEO QUEST (PROJECT #25-143, SEPTEMBER 9, 2025) AS USDA SANDY LOAM; TYPE 2-A; WITH AN LTAR OF 0.50 GPD/SF. 4.SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=560 GPD: 4.A.SPRING, WELL OR POTABLE CISTERN=100' 4.B.POTABLE WATER SUPPLY LINE=25' 4.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=20' 4.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=10' 4.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 4.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 4.G.LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 4.H.DRY GULCH, CUT BANK OR FILL AREA=25' 4.I.SEPTIC TANK=5' 4.J.RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3.SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A.SPRING, WELL OR POTABLE CISTERN=50' 3.B.POTABLE WATER SUPPLY LINE=10' 3.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=5' 3.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=5' 3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G.LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H.DRY GULCH, CUT BANK OR FILL AREA=10' 3.I.STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' FLOW Scale: N.T.S. SITE & SOILS EVALUATION SYSTEM DESIGN & CONSTRUCTION NOTES: 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72-HOURS PRIOR TO THE DESIRED TIME OF BACKFILLING. 2.DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A.ONE (1) BARN/SHOP USING TREATMENT LEVEL 1 (TL1). 2.B.AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD5): 2.B.1.ADWF: 2.B.1.1.BARN/SHOP BATHROOM = 35 gpd * 3 EMPLOYEES (FACT./PLATS EXCL. OF IND. WW PER EMPLOYEE-SHOWER PROV.) = 105 gpd 2.B.1.2.PERSONAL TRAVEL TRAILER DUMP = 50 gpd * 1 TRAILER = 50 gpd 2.B.1.3.HORSE WASH = 30 gpd * 7 HORSES = 210 gpd 2.B.1.4.TOTAL: 365 gpd 2.B.2.BOD5: 2.B.2.1.BARN/SHOP BATHROOM = 0.08 lbs/day * 3 EMPLOYEES = 0.24 lbs/day 2.B.2.2.PERSONAL TRAVEL TRAILER DUMP= 0.12lbs/day * 1 TRAILER = 0.12 lbs/day 2.B.2.3.HORSE WASH = 0.30lbs/day * 7 HORSES = 2.10 lbs/day 2.B.2.4.TOTAL: 2.46 lbs/day BOD5 mg/L = BOD5*1,000,000 = 2.46 lbs/day*1,000,000 = 808.1 mg/L ADWF*8.34 365 gpd*8.34 2.B.3.CBOD5 = BOD5 * 0.85 = 686.88 mg/L 3.SEPTIC TANK (SEC.43.9.B.2.a): 3.A.48-HOURS OF MINIMUM DETENTION TIME: ADWF * 48 hrs/24 hrs = 365 * 48 hrs/ 24 hrs = 730 GALLONS. 3.B.INSTALL A 1000 GALLON TWO-COMPARTMENT SEPTIC TANK WITH EFFLUENT FILTER IN THE OUTLET RISER. 3.C.THE TANK MAY BE SUBJECT TO BUOYANCY (SEE DETAIL). 4.ABSORPTION AREA CALCULATIONS: 4.A.THE ABSORPTION AREA SLOPES GENTLY. 4.B.LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.50 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.C.MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 365 = 730 S.F. LTAR 0.50 gpd/S.F. 4.D.SIZE ADJUSTMENT FACTORS: GRAVITY BED = 1.2; CHAMBERS = 0.7 (TABLE 10-2 AND 10-3). 4.D.1.A,adj = 730 SF * 1.2* 0.7 = 614 SF 4.E.GRAVELLESS CHAMBER TRENCH SYSTEM: 4.E.1.INFILTRATOR QUICK4: 614 SF / 12 SF/UNIT = 52 UNITS. INSTALL 52 UNITS IN A 4x13 UNIT BED CONFIGURATION. 4.E.2.ADS ARC 36: 614 SF / 15 SF/UNIT = 41 UNITS. INSTALL 44 UNITS IN A 4x11 UNIT BED CONFIGURATION. 5.THIS SYSTEM IS SIZED FOR TYPICAL HOUSEHOLD WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. BACKWASH AND FLUSHING FLOWS SHALL BE DISPOSED OF WITHIN A SEPARATE INFILTRATIVE SYSTEM (SEE BELOW). 6.CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS GREATER THAN 45° AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8.INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9.INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10.SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. Scale: N.T.S. TWO-WAY CLEANOUT Scale: N.T.S. GRAVESLLESS CHAMBER ABSORPTION BED BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.1'±. (TYP.). IF NECESSARY TO ACHIEVE THIS SURFACE, IMPORT CONCRETE SAND TO USE AS LEVELING MATERIAL. REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. 4"Ø PERFORATED PVC PIPE. EXTEND PIPE TO REST ON BOTTOM OF THE BED COVER WITH 6" OF TOPSOIL AND REVEGETATE 12 " M I N . , 24 " M A X . GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL. FILL OVER THE CHAMBERS WITH UNCOMPACTED WELL GRADED LOCAL SOILS. 4"Ø COUPLING (UNION). USE A HOLE SAW TO CUT OUT CIRCLE OFF THE CENTER OF THE UNIT STANDARD INSPECTION PORT, TYP. (4"Ø PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY.CIRCULAR IRRIGATION-STYLE VALVE BOX & COVER - LID COLOR PURPLE OR GREEN - LABEL "SEWER" GENERAL ABSORPTION AREA NOTES 1.INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2.ABSORPTION BEDS SHALL NOT EXCEED 12' WIDE BY 100-FEET IN LENGTH, SHALL PARALLEL THE TOPOGRAPHY AND SHALL BE INSTALLED IN A RECTANGULAR PATTERN WHENEVER POSSIBLE. 3.THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4.DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5.NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6.UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE EXCAVATION. 7.TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. 8.WHEN MULTIPLE BEDS ARE USED, BEDS SHALL BE SEPARATED BY 6-FEET MIN. OF UNDISTURBED SOILS. 2. 7 ' BUOYANT FORCE: FB= (LxWxH)x(62.4 pcf) FB=(9.25x5x2.7)x(62.4 pcf) FB=7793 lbs STRUCTURE WEIGHT = 11535 lbs 11535 > 7793 THEREFORE NO ADDITION CONCRETE BLOCKS ARE REQUIRED. SOIL CALVING/ POTENTIAL SEASONAL GROUNDWATER Highway 6