Loading...
HomeMy WebLinkAboutOWTS Permit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address:86 Native Springs Drive, GWS, CO 81601 Parcel No.: _217711102002 Owner Name: Jaime Covarrubio Owner Phone: (970) 538-4399 Designer: Boundaries Unlimited Designer Phone: (970) 945-5252 Number of Bedrooms: N/A Minimum Tank Capacity: 1000-gallons Minimum Absorption: 511 ft 2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9558_______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _11/06/2025____________________ Expiration Date_11/06/2026_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with scope of work and site plan as submitted by Boundaries Unlimited dated November 4, 2025. Changes to the design and permit must be approved by Garfield County Public Health prior to construction. The new OWTS will serve a new barn and shop with a bathroom, temporary travel trailer hook up, and horse wash. A new 1250-gallon two compartment concrete septic tank set level with access to grade and a screened high-head pump in the second chamber will be installed. Effluent will be pumped to a level manifold that will distribute effluent to 528 ft2 of STA. The dose volume from the pump shall be 35 gallons pumped 10-11 times per day. The specified pump for the project has a 30 gallon-per-minute pump rate with a total dynamic head of 25 feet. The new STA will consist of a gravel-less chamber bed consisting of four rows of 11 ‘Quick 4’ chambers (44 chambers total). The infiltrative surface must be installed at a maximum of 1ft below grade to achieve adequate separation from seasonal high groundwater. Each trench will contain a perforated distribution lateral. Distribution laterals are to be 1 ¼ inch Schedule 40 PVC, with 3/16-inch orifices every 5-feet on center and the laterals ending in 90-degree sweeping bends and flushing valves at the distal end. The residual head (squirt height) at the end of the system is to be 5-feet. The orifices are to be facing upward, except for the last orifice (which shall face downward and be equipped with a splash plate). Inspection ports will be installed at each corner of each bed. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 11/06/2025 Issued By: Garfield County Environmental Health Department Date