HomeMy WebLinkAboutEngineer's OWTS Design PlanHuddleston-Berry
Engineering & Testing, LLC
Dale Bauer
dale@truenorthcolorado.com
Subject: OWTS Design
611 Scutter Lane
Rifle, Colorado
Dear Mr. Bauer,
2789 Riverside Parkway
Grand Junction, Colorado 81501
Phone: 970-255-8005
Info@huddlestonberry.com
October 30, 2025
Project#03122-0001
At your request, Huddleston-Berry Engineering & Testing, LLC completed design of an Onsite
Wastewater Treatment System (OWTS) for a new single-family residence at 611 Scutter Lane in
Rifle, Colorado. The site location is shown on Figure 1 — Site Location Map. A site plan is
included as Figure 2.
Site Description
At the time of the investigation, the site was open with undulating terrain. The investigated area
was located on a hilltop. Topography surrounding the investigated area consisted of moderate to
steep slopes. Site topography is shown on Figure 2. Vegetation consisted primarily of weeds,
grasses, and trees. The site was bordered to the north, west, east, and south by large residential
parcels.
Subsurface Investigation
In order to evaluate the subsurface conditions at the site, four test pits were excavated across the
site. Using visual -tactile classification methods, the soil profile consisted of 1.0 foot of topsoil
above tan and brown, moist, medium dense silt loam soils with a weak granular structure to the
bottoms of the excavations. The site soils are consistent with Soil Type 2A.
Groundwater was not encountered in the subsurface at the time of the investigation. In general,
based upon the results of the subsurface investigation, HBET believes that the seasonal high
groundwater elevation is deeper than 8.0 feet below the existing grade at this site.
The locations of the test pits are shown on Figure 2. Copies of the test pit logs are included in
Appendix A.
611 Scutter Lane
#03122-0001
10/30/25
Onsite Wastewater Treatment System
y9Huddlcston-Berry
1 ,,&K,6n & Ttt 1,g, LLC
Seepage Bed Design
The design of the absorption system generally follows the requirements of the Garfield County
Department of Public Works as outlined in the Garfield County On -Site Wastewater Treatment
System Regulations, effective June 2018. The proposed construction at the site is anticipated to
include a three -bedroom residence.
Based upon the visual tactile classification of the soils, a Long -Term Acceptance Rate (LTAR)
of 0.5 will be utilized for the absorption field design. Infiltrator Systems Quick4 Standard
Chambers are proposed. The daily flow of the sewage disposal system is calculated below and a
plan and profile of the absorption system are shown on Figure 3.
Average Daily Flow = (6 persons)(75 GPD/person)
= 450 GPD
Soil Treatment Area = (450 GPD / 0.5) = 900 Square Feet
Adjusted Soil Treatment Area = (900 SF)(1.2)(0.7) = 756 Square Feet
# of Quick4 Chambers = (756 / 12) = 63 Chambers; Use 64 Chambers
System Installation
The installation of the septic tank, plumbing lines, Infiltrators, etc. should be completed in
accordance with the Garfield County On -Site Wastewater Treatment System Regulations and
Infiltrator Systems, Inc. specifications. In addition, the following construction procedures are
recommended:
• The septic tank and distribution box should be placed level over native soils that have
been scarified to a depth of 8 to 12 inches, moisture conditioned, and recompacted to
a minimum of 95% of the standard Proctor maximum dry density, within f2% of
optimum moisture content. However, up to 3-inches of washed rock or pipe bedding
passing the 1-inch sieve may be used as a leveling course under the septic tank and/or
distribution box.
• The bottoms of trenches and backfill around the septic tank and distribution box
which will support sewer or effluent lines should be compacted to at least 90 percent
of the standard Proctor maximum dry density, within f2% of optimum moisture
content. Pipe bedding should have a maximum particle size of 1-inch.
■ Vehicular or heavy equipment traffic and placement of structures should not encroach
within 10 feet of the septic tank or distribution box.
Inspection Schedule
Huddleston-Berry Engineering & Testing LLC should be retained to monitor the construction of
the OWTS. The following schedule of observation and/or testing should be followed:
■ Observe the absorption bed excavation prior to placement of Infiltrator chambers.
Observe placement of the septic tank, distribution box, and all connecting sewer and
effluent lines prior to backfill. Verify proper fall between inverts.
■ Observe and verify installation of the absorption bed prior to placement of cover and
backfill.
YA2008 ALL PROJECTS\03122 -Dale Bauer\03122-0001 611 Scutter Lane\200 - Geo\03122-0001 OWTS103025.doc 2
611 Scutter Lane n
#03122-0001 Huddleston-Bcrty
E,&... i,g S T,,11,g, LLC
10/30/25
In conformance with Garfield County regulations, HBET will be required to provide the Garfield
County Health Department with documentation certifying that the OWTS was placed in
conformance to the plan and profile and Garfield County regulations.
General Notes
The OWTS design was based upon the results of the subsurface investigation and on our local
experience. The design is valid only for the proposed construction.
We are pleased to be of service to your project. Please contact us if you have any questions or
comments regarding the contents of this report.
Respectfully Submitted:
Huddleston-Berry Engineering and Testing, LLC
Wayne D. Anderson, P.E.
Project Engineer
YA2008 ALL PROJECTS\03122 - Dale Bauerk03122-0001 611 Scutter Lane\200 - Geo\03122-0001 OWTS103025.doc 3
FIGURES
Puh j���_���e Garfield County, CO
�_ �_
FIGURE I
Date created: 4/11/2024
Last Data Uploaded: 4/11/20242:16:08 AM Site Location Map
Developed by(,,m Schneider
10ECS PAT! 7,L
SITE PLAN
EXISTMDDRNE'PIAY-
>;7C18Tpt6ODON5ET
Exlsmaa CONW ETE SLAB I
I
;]11 R VEANBIXfAVARY
I I
rj Z
"AS5ULIED WATER L L_�
U LOCATION
tYtiEi
SCALE: 1 " = 200'
C.I.=2FT F�
r TEST PITL�
ENLARGED VIEW
��E1O6TC1G DRIVEIYAY
!ENLARGED YEi'1 BOUNDARY 7
II IXISTING
GUONSET
ASSULIEDWATE4
iLINE LOCATION
S *TM OFFAL
i /EXISTING CONCRETE SLAB
BUILDING i
i
NEW
RESIDENCE
i
i
iPTIC
TAHK WITH
COVEREDPORCH
MINIMUM 1,000
iGALLON
CAPACITY
i
STA
-REPAIR AREA- I
SIZED FOR SEQUENTIAL I
if
'-DISTRIBUTION
SCALE: 1" = 30
GENERALIZED SYSTEM PROFILE
NOT TO
SCALE
RESI➢ENTIAL
aSSCRi 0ai NI=STAAn
STRUCTURE
yLf�Alys
=N TINT LIES A AT
E4 A4WL iLRW VN9C
IflILfRAIyA OulCN IiwlT,wq➢ CIVA4m
1AI FT !OK N'IR
AI Iila➢0f1 L
LTA. Y➢
TO �A f T
EST. 1.0 FT
L5 FT NAK.
LO FT MIN LOVER —
0[SailNsiPA MI VITN
iI.OV ibYL1ARS
e Ca1WARW AP SEPTIC TAW(
C➢PIE APPROVED TANK
N ag F TICE
La PR[l"T T[E
LFRT IST
LIST
GENERALIZED BED PROFILE
NOT TO
SCALE
...... SCALE ____----___,
.%ILj ..R UF43 AtI1NS[[pp��3' 17,YE 12'X64' BED I
5C'IRF11{4nSi�;II RD INFILTRATORS OR
L______________________J
DII;LTRATOR SYSTEMS QUICK4 C(AWA 60IL. NATIVE SOILS OR OTHER SUITABLE
STAti01ARBGT lArF.RS [UI!SOII PRAW TO CARRY SURFACE WATER
{t AWAY M)M IIFJ1
XO.NW(WIX NEEDLE PUNCI IED.AIEQIi"AT11]:
FABRIC IMMEDIATELY ABOVE CHAMBERS
MINIMUM SETBACKS
(UNITS = FT)
— w
f
axa a.o uI
LYIu NfCx
LAa. a a.reY
9v¢Lw➢
ux➢aw
,>rAvicerr Llx:
glue
a4
9F
1
Ia
WO 23
J7
q
e3
!a
S
00 q
10
b
M
"OTHER SETBACKS NOT LISTED HERE SHOULD BE IN ACCORDANCE WITH GARFIELD COUNTY OWTS REGULATIONS
DETAIL AREA
SCALE: V = 20'
LNE LOCATION
NNW 11=%".6
PORTS
4 ROWS OF 16 QUICK4
STANDARD IN PILTRATORS OR
ENGINLER APPROVED EQUAL
PORTS
"USE SWEEP 90-S OR
TW043-SAT90
DEGREE BENDS—
PI
MIN SkPrIC T&VK Willi
7JLtiLA{L51 ].000
GALLON CAPACITY
4-INCH DIAMETER SEWER AND
EFFLUENT PIPE AIETT,NO ASTNI
DITSS. SCHEDULE 40 OR SDR 35
rK^' BOR THAT
EVEN DISTRIBUTION
Project No.: 03122-0001 611 SCUTTER LANE
+! Huddleston-Berry PARCEL#212728400387
Date: 10/30/25 Engineering a Tearing, LLC
2789 Riverside Parkway FIGURE 3 - SEPTIC SYSTEM
By: WDA Grand Junction, CO 81501 DETAILS
APPENDIX A
Typed Test Pit Logs
' 1iEE Huddleston-Bevy Engineering & Testing, LLC TEST PIT NUMBER TP-1
2789 Riverside Parkway PAGE 1 OF 1
Grand Junction, CO 81501
970-255-8005
CLIENT Dale Bauer PROJECT NAME 611 Scutter Lane
PROJECT NUMBER 03122-0001 PROJECT LOCATION Rifle, CO
DATE STARTED 3/19/24 COMPLETED 3/19/24 GROUND ELEVATION TEST PIT SIZE _
EXCAVATION CONTRACTOR Wiseland GROUND WATER LEVELS:
EXCAVATION METHOD Trackh/Backhoe _ AT TIME OF EXCAVATION Dry
LOGGED BY TEC CHECKED BY MAB AT END OF EXCAVATION Dry
NOTES AFTER EXCAVATION --
"-'
o
z
U
��
Lu
rnw
w
0
w
Q p
MATERIAL DESCRIPTION
-j g
0-0
> x
o�
-j o>
Y N
0
O
Ur
2Z
W
mo
UZ
O
W
of
a
0
Silt Loam, tan and brown, moist, medium dense, weak granular
structure (Soil Type 2A)
Bottom of test pit at 7.0 feet,
w o
ATTERBERG
LIMITS}
z
w
~
LOLu
U�
�F
F-
Uw
O
z0
��
g=
U)z
w
U
o
a-
LL
SREF , Huddleston-Bcny Engineering & Testing, LLC TEST PIT NUMBER TP-2
2789 Riverside Parkway PAGE 1 OF 1
Grand Junction, CO 81501
970-255-8005
CLIENT Dale Bauer PROJECT NAME 611 Scutter Lane
PROJECT NUMBER 03122-0001 PROJECT LOCATION Rifle, CO
DATE STARTED 3/19/24 COMPLETED 3/19/24 GROUND ELEVATION TEST PIT SIZE
EXCAVATION CONTRACTOR Wiseland GROUNDWATER LEVELS:
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION Dry
LOGGED BY TEC CHECKED BY MAB AT END OF EXCAVATION Dry
NOTES AFTER EXCAVATION —
ATTERBERG
l-
a
o
z
w o
LIMITS
w
❑
U
X
2
U
HW
wm
�^
w❑
H❑
5ZJ
w
D
H�
H
U
❑~
I-Z
Z
Oo
(L
w v
Q p
MATERIAL DESCRIPTION
J
a�
>
O�
Lu v
z a
U
_
U .
❑
<
p
Qz
w
m0
Uz
U
O
}v
rr
Oz
20
d�
�J
Q�
-j
�p
z
w
U
tr
o
❑
U
°
0.0
ELz
`
Sandy Clay with Gravel and Organics (TOPSOIL)
Silt Loam, tan and brown. moist. medium dense, weak granular
structure (Soil Type 2A)
2,5
5.0
7.5
Bottom of test pit at 8.0 feet.
" r Huddleston-Berry Engineering & Testing, LLC TEST PIT NUMBER TP-3
2789 RivcTside Parkway PAGE 1 OF 1
Grand Junction, CO 81501
970-255-8005
CLIENT Dale Bauer PROJECT NAME 611 Scutter Lane
PROJECT NUMBER 03122-0001 PROJECT LOCATION Rifle CO
DATE STARTED 3119124 COMPLETED 3/19/24 GROUND ELEVATION TEST PIT SIZE
EXCAVATION CONTRACTOR Wlseland GROUND WATER LEVELS:
EXCAVATION METHOD TrackhlBackhoe AT TIME OF EXCAVATION Dry
LOGGED BY TEC CHECKED BY MAB AT END OF EXCAVATION Dry
NOTES AFTER EXCAVATION --
Lu
o
z
U
}
U) W
LLI
o_
w
Q p
MATERIAL DESCRIPTION d�
m Z) j
I--
N
pOf
2 Z
U Z
UO
W
U
4. p
0.0
Sandy Clay with Organics (TOPSOIL)
—'
Silt Loam, tan and brown, moist. medium dense, weak granular
structure (Soil Type 2A)
bottom oT test pit at b.0 Teet.
3�
ATTERBERG
w o
LIMITS
z
w
H
�Lu
pH
UW
OUP
H
�J
CA
H p
rq
20
dJ
gZ
Lu
R
LL
Huddleston-Berry Engineering & Testing, LLC TEST PIT NUMBER TP-4
2789 Riverside Parkway PAGE 1 OF 1
Grand .function, CO 81501
970-255-8005
CLIENT Dale Bauer PROJECT NAME 611 Scutter Lane
PROJECT NUMBER 03122-0001 PROJECT LOCATION Rifle CO
DATE STARTED 3/19/24 COMPLETED 3/19/24 GROUND ELEVATION TEST PIT SIZE
EXCAVATION CONTRACTOR Wiseland GROUND WATER LEVELS:
EXCAVATION METHOD Trackh/Backhoe AT TIME OF EXCAVATION Dry
LOGGED BY TEC CHECKED BY MAB AT END OF EXCAVATION dry
NOTES AFTER EXCAVATION —
ATTERBERG
a
o
z
W o
LIMITS
w
U
U
>-
[o
oZ
d
ZOfQwC3(D
z
0ap 0"
W
MATERIAL DESCRIPTIONWm
0x
Y
ZaU)�
mg
WU
0
p
Ozp
�
Z
m
WZ
<
of
0_
2O
J
IL
0.0
ng
ILL
—
Sandy Clay vnth Organics (TOPSOIL)
.0 Ir. ".
Silt Loam, tan and brown. moist, medium dense, weak granular
structure (Soil Type 2A)
2.5
5.0
Bottom of test pit at 6.0 feet.