Compliance Certificate
Project Information
Project Title:
Energy Code:
Location:
Construction Type:
Project Type:
Project Sub Type:
Orientation:
Conditioned Floor Area:
Glazing Area:
Climate Zone:
Project No:
All Electric:
Is Renewable:
Has Battery:
Has Charger:
Has Heat Pump
Construction Site:
647 ELK SPRINGS DRIVE
GLENWOOD SPRINGS, CO 81601
Project Notes:
STUEVEN STRUCTURES
2018 IECC
Garfield, Colorado
Single Family
New Construction
None
Bldg. faces 0 deg. from North
3815 ft2
22%
5b (8499 HDD)
1768937
false
false
false
true
false
Owner/Agent:
RYAN STUEVEN
647 ELK SPRINGS
STUEVEN STRUCTURES
GLENWOOD SPRINGS, CO 81601
RYAN@STU EV ENSTRUCTU RES. COM
Designer/Contractor:
BRAD JORDAN
PO BOX 1031
JORDAN ARCHITECTURE
GLENWOOD SPRINGS, CO 81602
9706186690
BRADJO RDANARCHITECT@G MAI L.CO M
E ui Trust CQar arr ` BLRF td-25 4S44
sfa � "4y �� Na an t1J1
5394noi4
Report Title: STUEVEN STRUCTURES Report Date: 10/9/25, 8:28 AM 1 of 13
Envelope Assemblies
Assembly
Gross Area or
Perimeter
Cavity
R Value
Cont.
R-Value
Prop.
U-
Factor/
F-Factor
Req.
U-
Factor/
F-Factor
Prop.
UA
Req.
UA
Ceiling: Flat Ceiling or
2835
49.0
0.0
0.026
0.026
74
74
Scissor Truss
Floor: Slab -On -Grade
164
10.0
0.660
0.700
❑
0
(Unheated)
Insulation depth: 3.00'
Insulation position:
Horizontal Insulation
Crawl Wall: Solid Concrete
1880
19.0
10.0
0.035
0.055
33
52
or Masonry
Wall height: 5.00
Depth below grade: 1.00
Insulation depth: 4.00'
Wall: Wood Frame, 16" o.c.
624
20.0
6.0
0.042
0.060
20
28
Orientation: Unspecified
Window: Wood Frame
108
0.260
0.300
28
32
Orientation: Unspecified
Door: Glass Door (over
48
0.300
0.300
14
14
50% glazing)
Orientation: Unspecified
Wall 1: Wood Frame, 16"
570
20.0
6.0
0.042
0.060
22
32
O.C.
Orientation: Right side
Window 1: Wood Frame
37
0.260
0.300
10
11
Orientation: Right side
Wall 2: Wood Frame, 16"
1004
20.0
6.0
0.042
0.060
27
39
O.C.
Orientation: Back
Window 2: Wood Frame
200
0.260
0.300
52
60
Orientation: Back
Door 1: Glass Door (over
152
0.300
0.300
46
46
50% glazing)
Orientation: Back
Wall 3: Wood Frame, 16"
532
20.0
6.0
0.042
0.060
20
28
O.C.
Orientation: Left side
Window 3: Wood Frame
38
0.260
0.300
10
11
Orientation: Left side
Door 2: Glass Door (over
20
0.300
0.300
6
6
50% glazing)
Orientation: Left side
Basement Wall: Solid
224
19.0
10.0
0.031
0.050
7
11
Concrete or Masonry
Orientation: Unspecified
Wall height: 8.00
Insulation depth: 8.00'
Insulation position:
Integral Insulation
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES
NOT provide an estimate of energy use or cost relative to a minimum -code home.
Slab -on -grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab -on -grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Compliance Statement
submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title
/o , 9,Z5
Date
Report Title: STUEVEN STRUCTURES Report Date: 10/9/25, 8:28 AM 3 of 13
C�(JlInspection Checklist
Energy Code: 2018 IECC
Requirements: 0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being
claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Pre-Inspection/Plan Review
Section
& Req.ID Pre-Inspection/Plan Review
103.1, Construction drawings and
103.2 documentation demonstrate
[PR1]1 i enemy code compliance for the
building envelope. Thermal
envelope represented on
construction documents.
Plans Field
Verified Verified
Value Value
Complies?
Complies
PoDoesNot
omply
Not
servable
(� Not
pplicable
Comments/Assumptions
103.1, Construction drawings and
103.2, documentation demonstrate
Complies
403.7 energy code compliance for
Does Not
[PR3]1 lighting and mechanical
omply
systems. Systems serving
multiple dwelling units must
Not
demonstrate compliance with
66servable
the IECC Commercial Provisions.
Not
Oplicable
302.1. Heating and coolie equipment
403.7 i ,sized per ACCA iNanua[ 5
[PR2]2 based on loads calculated per
ACCA Manual I or other methods
i approved by the code official.
Additional Comments/Assumptions:
Heating:
Btulhr
Heating:
8tu1Hr
Complies
Does Not
I Pmply
Cooling:
Btulhr
Cooling:
Btu
Not
servable
1
i
PpNot
plicable
1 1 High Impact (Tier 1) 1 2 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3)
Foundation Inspection
Section
& Req.ID Foundation Inspection
402.1.2 Slab edge insulation R-value
[FO1]1
303.2.1 A protective covering is
[F011]2 Installed to protect exposed
exterior insulation and extends
a minimum of 6 in. below grade.
403.9 Snow- and ice -melting system
[FO12]2 controls installed_
402.1.2 Slab edge insulation
[F03]1 depth/length.
Plans
Verifled
Value
Field
Verifled
Value
Complies?
f
y Ro=
R
0 Complies
OUnheated
OUnheated
Does Not
Comply
Heated
Heated
❑ Not
Observable
Not
Applicable
Ej Complies
Does Not
Comply
n Not
Observable
0 Not
Applicable
l
Complies
Does Not
Comply
Not
servable
Not
Applicable
^i ft
C ft^
0 Complies
Q Does Not
Comply
Not
servable
Q Not
Applicable
Comments/Assumptions
See the Envelope
Assemblies table for
values
See the Envelope
Assemblies table for
values
402.1.1 Conditioned basement wall
Complies See the Envelope
[F0411 insulation R-value. Where
"�7 Assemblies table for
Q Does Not values
interior insulation is used,
R=
,
�[�
"� Comply
verification may need to occur
during Insulation Inspection. Not
n Not
required in warm -humid
O servable
locations in Climate Zone 3.
Not
Applicable
303.2 Conditioned basement wall
[F0511 insulation installed per
manufacturer's instructions.
1 402.2.9 Conditioned basement wall
[F06]1 insulation depth of burial or
distance from top of wall.
402.2.11 Unvented crawl space wall
[F0711 insulation R-value.
Complies
El Does Not
Comply
QNot
O servable
O Not
Applicable
U ft
L ft
Q Complies
^�
Does Not
omply
Not
servable
Not
Applicable
R=
R,=
Complies
R=
R=
Does Not
omply
Not
O servable
0 Not
Applicable
i See the Envelope
Assemblies table for
values
See the Envelope
Assembfies table for
values
Report Title: STUEVEN STRUCTURES Report Date: 10/9/25, 8:28 AM 5 of 13
Section Plans Field
# Verified Verified _ <
& Req.1O Foundation inspection Value value complies? Commeltti/lssumptioit9
303.2 Unvented crawl space wall
[FO8]1 insulation installed per
manufacturer's instructions.
402.2.11 invented crawl space
[17O9]1 continuous vapor retarder
installed over exposed earth.
joints overlapped by 6 in. and
sealed. extending at least 6 in.
up and attached to the wall.
Complies
PoDoesNot
omply
Xot
ervable
Not
pplicable
Complies
Does Not
omply
Not
servable
PNot
plicable
14uz.1.11 Unvented crawl space wall in
[FO10]1 Insulation depth of burial or
in.
❑ Complies See the Enveloppe
distance from top of wail.
Does Not Assemblies table for
values
omply
Not
servable
QNot
pplicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) � , Low Impact (Tier 3)
Framing / Rough -in inspection
Section
#
Framing / Rough -In
& Req.ID
Inspection
402.1.1
Glazing U-factor (area -weighted
402.3.1:
average).
402.3.3,
402.5
[FR2]1
402.4.1.1
Air barrier and thermal barrier
[FR23]1
installed per manufacturer's
instructions.
Plans
Field
Verified
Verified
Value
Value Complies?
Comments/Assumptions
Complies
See the Envelope
U
Assemblies table for
Does Not
values
Comply
Not
Q[^]
servable
n Not
Applicable
0 Complies
PoDoesNot
omply
Not
O servable
0 Not
Applicable
402.4.3
Fenestration that is not site built
[FR20]1
is listed and labeled as meeting
AAMA /WDMA/CSA
101A.S.21A440 or has infiltration
rates per NFRC 400 that do not
exceed code limits.
402.4.5
f IC -rated recessed lighting
[FR16]2
I fixtures sealed at
housing/interior finish and
labeled to indicate s2.0 cfm
leakage at 75 Pa.
403.3.1
Supply and return ducts in attics
[FR12]1
insulated >= R-8 where duct is
>= 3 inches in diameter and
>= R-6 where < 3 inches.
Supply and return ducts in other
portions of the building
Jnsulated �= R-6 For diameter
>= 3 inches and R-4.2 for < 3
inches in diameter.
403.3.2
Ducts, air handlers and filter
[FR13]1
boxes are sealed with
joints/seams compliant with
International Mechanical Code
or International Residential
Code, as applicable.
403.3.5 Building cavities are not used as
[FR15]3 ducts or plenums.
0 Complies
P Does Not
Comply
Wot
ervable
0 Not
Applicable
Complies
Does Not
Comply
Not
servable
Not
Applicable
0 Complies
0 Does Not
Comply
Not
servable
Not
pplicable
0 Complies
0 Does Not
Comply
Not
O servable
0 Not
Applicable
0 Complies
0 Does Not
Comply
QNot
O servable
0 Not
Applicable
Report Title: STUEVEN STRUCTURES Report Date: 10/9/25, 8:28 AM 7 of 13
Section
#
& Req.ID
Framing / Rough -In
Inspection
403.3.7
Ducts declared to be within the
[FR28]3
conditioned space are either 1)
completely within the
continuous air barrier and within
the building thermal envelope,
2) buried within ceiling
insulation in accordance with
Section R403.3.6 and the air
handler is located completely
within the continuous air barrier
and within the building thermal
envelope and the duct leakage
is <= 1.5 cfm 1 100 square feet
of conditioned floor area served
by the duct system, or 3) the
ceiling insulation R-value
installed against and above the
insulated duct >= to the
proposed ceiling insulation R-
value, less the R-value of the
insulation on the duct.
Plans Field
Verified Verified
Value Value Complies? Comments/Assumptions
403.4 HVAC pipin conveying fluids
[FR17]2 above 105 -F or chilled fluids R I R
below 55 °F are insulated to >_R-
3. f
403.4.1 Protection of insulation on HVAC
[FR24]1 piping.
403.5.3 Hot water pipes are insulated to . j� 1
[FR18]2 ?R-3. R R j
403.6
[FR19]2
i
303.1.3
[FR4]1
i
Automatic or gravity dampers
are installed on all outdoor air
intakes and exhausts.
U-factors of fenestration
products are determined in
accordance with the NFRC test
procedure or taken from the
default table.
Additional Comments/Assumptions:
Complies
PDoes Not
,imply
Not
servable
Not
pplicable
O Complies
,imDoes Not
ply
6 Not
servable
Not
pplicable
Complies
Does Not
,imply
Not
servable
Not
pplicable
Complies
Does Not
omply
Not
servable
Not
pplicable
Complies
Does Not
Imply
Not
servable
Not
pplicable
❑ Complies
i
PoDoesNot
omply
i n Not
j 66servable
Not
pplicable
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Insulation Inspection
Section Plans Field
Verified Verified
Z a# In Insulation Inspection Value Value Complies?
[IN131}
402.1.1,
402.2.5,
402.2.6
[IN311
303.2
[IN411
All installed insulation is labeled
Q Complies
or the installed R-values
Does Not
provided.
omply
Not
servable
Not
pplicable
Wall insulation R-value. If this is
R;
Rj
0Complies
a mass wall with at least Y2 of
the wall insulation on the wall
Q Wood
Q Wood
Does Not
exterior, the exterior insulation
requirement applies (FR10).
Q Mass
Q Mass
omply
QQ Not
Q Steel
Q Steel
Observable
Q Not
Applicable
Wall insulation is installed per
Q Complies
manufacturer's Instructions.
Does Not
Pomply
Not
servable
PNot
plicable
Additional Comments/Assumptions:
Comments/Assumptions
See the Envelope
Assemblies table for
values
1 High Impact (Tier 1) 2 _ Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Report Title: STUEVEN STRUCTURES Report Date: 10/9/25, 8:28 AM 9 of 13
Final Inspection Provisions
Section
frVerified
& Req.l0
Mae] Inspection Provisions Value
4021.1,
Ceiling insulation R-value.
402:2.1.
R-[
402.2.2,
Wood
402.2.6
[F11]1 0 Steel
303.1.1.1, Ceiling insulation installed per
303.2 manufacturer's instructions.
[FI2]1 Slown insulation marked every
300 ft'.
403.1.2 Heat pump thermostat installed
[F110)a on heat pumps.
403.5.1 Circulating service hot water
[F111]2 systems have automatic or
accessible manual controls.
1403.6.1 All mechanical ventilation
[F125F system fans not part of tested
and listed HVAC equipment
meet efficacyy and air flow limits
per Table R403.fi,1,
I
Field
Verified
Value
Complies?
Complies
O Wood
Does Not
amply
Steel
[ ] Not
Observable
Not
pplicable
Complies
Does Not
❑mply
4ot
rvable
Not
pplicable
Complies
Does Not
amply
Not
servable
Not
Pplicable
Complies
Does Not
amply
Not
servable
Not
pplicable
❑ Complies
PoDoesNot
omply
Not
servable
Not
pplicable
Cornme ntslAss umpti ons
See the Envelope
Assemblies table for
values
403.2 Hot water boilers supplying heat
El Complies
[FI26]2 through one- or two -pipe
heating systems have outdoor
Does Not
setback control to lower boiler
omply
water temperature based on
outdoor temperature.
�} Not
Observable
j Not
pplicable
403.5.1.1 Heated water circulation
Complies
[FI28]2 systems have a circulation
pump. The system return pipe is
Does Not
a dedicated return pipe or a
amply
cold water supply pipe. Gravity
and thermos syphon circulation
Not
systems are not present.
Controls for circulating hot
serva,le
Not
water system pumps start the
�}
pplicable
pump with signal for hot water
demand within the occupancyy.
Controls automatically turn off
the pump when water is in
circulation loop is at set -point
temperature and no demand for
hot water exists.
403.5.1.2 Electric heat traces tems
MM
� Complies
[FI29]7 comply with IEEE or UL
515. Controls automatically
Does Not
adjust the energy input to the
Imply
heat tracing to maintain the
desired water temperature in
❑Not
the piping.
Dhservabke
Not
pplicable
& Req.ID
Final Inspection Provisions
403.5.2
Demand recirculation water
[F130]2
systems have controls that
manage operation of the pump
and limit the temperature of the
water entering the cold water
piping to <= 1049F.
403.5.4
Drain water heat recovery units
[FI31]2
tested in accordance with CSA
B55.1. Potable water -side
pressure loss of drain water
heat recovery units < 3 psi for
individual units connected to
one or two showers. Potable
water -side pressure loss of drain
water heat recovery units s 2
psi for individual units
connected to three or more
showers.
404.1
90% or more of permanent
[F[6]1
fixtures have high efficacy
lamps.
404.1.1 Fuel gas lighting systems have
[F123]3 no continuous pilot light.
I
401.3 Compliance certificate posted.
[F17]2
i
303.3
[FI18]3
402.2.3
[FI22]z
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Verified Verified
Value Value Complies? Comments/Assumptions
Complies
PoDoesNot
omply
Not
servable
Not
pplicable
Complies
Does Not
Comply
Not
O servable
IDNot
Applicable
Complies
Does Not
Comply
Not
Observable
Not
Applicable
Complies
Does Not
Comply
Not
servable
0 Not
Applicable
Complies
Q Does Not
Comply
qNot
O servable
Not
Applicable
Complies
PoDoesNot
omply
Not
servable
Not
Applicable
Vented attics with air permeable
f Complies
insulation include baffle
Does Not
adjacent to soffit and eave
vents that extends over
omply
insulation.
Not
O servable
Not
Applicable
402.2.4 Attic access hatch and door
R=
R= Complies
[FI3]1 insulation >_R-value of the
adjacent assembly.
Does Not0
Comply
QNot
O servable
E) Not
Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =
ACH 50 =
Q Complies
[FI17]1 ach in Climate Zones 1-2, and i'�
1
Does Not
<=3 ach in Climate Zones 3-8.
Comply
Not
Ob servable
Not
Applicable
Report Title: STUEVEN STRUCTURES Report Date: 10/9/25, 8:28 AM 11 of 13
Section
Plans
Field
4
Verified
Verified
& Req.10
Final inspAwtion Provisions
Value
value
Complies? ClmmentslAssumptions
403.3.3
Ducts are pressure tested to
-
Complies
[FI2711
determine air leakage with
either: Rough -in test: Total
Cfm/100 ft2
Cfm/100 ft2
Does Not
leakage measured with a
Imply
pressure differential of 0.1 inch
Not
w.g. across the system including
Rservable
the manufacturer's air handler
enclosure if installed at time of
Not
test. Postconstruction test: Total
pplicable
leakage measured with a
Pressure differential of 0.1 inch
w,g. across the entire system
including the manufacturer's air
handler enclosure,
403.3.4
Duct tightness test result of
[FI411
4 cfm/100 ft2 across the
system or a=3 cfm/100 ft2
w4hout air handler @ 25 Pa. For
rough -in tests, verification may
need to occur during Framing
Inspection.
403.3.2.1
Air handier leakage desiggnated
by manufacturer <—X.
[FI2411
at of
design airflow.
403.1.1 programmable thermostats
[FI91, installed for control of primary
heating and cooling systems
and initially set by manufacturer
to code specifications.
Additional Comments/Assumptions:
1 Complies
Cfm/100 ft2 Cfm/100 ft2 Does Not
Pmply
Not
servable
Not
pplicable
Complies
PoDoesNot
omply
[Not
servable
Not
pplicable
O Complies
PoDoesNot
omply
Not
servable
Not
pplicable
1 1 1 High Impact (Tier 1) Z Medium Impact (Tier 2) 3 Low Impact (Tier 3)
2018 I ECC Energy
Efficiency
Certificate
Insulation Rating R-Value.MM
Above -Grade Wall 26.00
Below -Grade Wall 29.00
Floor 10.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Window
i
0.26
Door
0.30
Skylight
0.00
Heating System:
Cooling System:
Water Heater:
i
Name:
Comments:
Date:
Report Title: STUEVEN STRUCTURES Report Date: 10/9/25, 8:28 AM 13 of 13