Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Blower Door Test Report
Testing Company: Name: Address: Technician: Name:Brian Chesney Credentials:BPI Certified ID#5068969 Email:c5energygj@gmail.com Building Information: Project ID:5322 cr243 Address:5322 County Road 243 New Castle, Colorado 81647 Geo-Tag Data:Latitude: 39.672564 Longitude: -107.567413 Timestamp: 2025-10-27 09:04:15 Customer Information: Name: Address: Measured Leakage:3.00 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:Blower door 5 Purpose of Test:Envelope (IECC) Measured CFM50:2,243.9 Effective Leakage Area: 123.4 in² Building Volume:44,849.0 ft³Enclosure Surface Area: 0.0 ft² Coefficient (C):176.5 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 60 °F Altitude: 6,195.0 ft Outdoor Temp: 48 °F Time Average Period: 10 seconds Test Date and Time:2025-11-18 13:05:18 10% Adjustment Applied: No Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.2 -50.0 -48.4 -47.2 -144.3 2,147.2 Ring A Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 13229 Calibration Date: 2024-08-27 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.2 (3), © 2025 The Energy Conservatory, Inc.