HomeMy WebLinkAbout53 CEDAR-AC-OWTS-C1-Record Drawing-120925E V v N 0 0 GV ❑ O = ❑00 N Z fV V 00 J oho w p0 DO _• .. = _ .., Z _ r� O STBK STBK - N ry TREATMENT LEVEL 3N PRESSURE DOSED CHAMBER BED DISPERSAL FIELD ❑ w Q LU INSTALLED 36 QUICK-4 PLUS LP CHAMBERS IN 4 ROWS IN A SINGLE (38' BY 12') BED WITH 9 CHAMBERS PER ROW AS SPRAY SHIELDS OVER THE 432 5.F NATIVE SOIL ABSORPTIIVE SURFACE. INSTALLE- RENCO. VERICOMM AX2QB2 CONTROL PANEL 2PV/HT,SA,MOV, IP, PSA CONTROL PANEL - - �E C fTA 25A' FRONT BUILD SETBACK INSTALLED CHAMBER ENE) CAPS (TYP.)­,! - EILIE / TRL WIRES FROM CONTROL PANEL. T EXTERIOR SPLICE BOX ON RISERS. INSTALLED 1.5" FLUSH BALLVALVE & 4" INSPECTION ; 1 . ' 10 .0' PORT W/ PUSH ON CAP FROM END CAP SET 3" BELOW FINISH GRADE & COVERED WITH 10" DIA. VALVE BOX SET W/ LID 1" ABOVE FINISH GRADE i (TYP. EACH DISTAL CHAMBER ROW END CAP) 13.7' 12 0 O iWVE OPE B 10N 3-BD R s L6 432 S.F PARKING W/ 4 ROW OF 9 -4 LP C MBRS PP PROPERTY LINE f x i / toX­� f f f f STBK STBK STBK STBK STBK - STBK 5 100' SETBACK FROM NEW WELL 3-COMPARTMENT 1,506-GALLON CONCRETE RECIRC. SEPTIC TANK WJORENCO SYSTEMS AbVANTEX AX-20 TREATMENT POE) WITH (3) 24" DIA. 8Y 48" DEEP RIBBED PVC RISERS WJ LIDS SET AT THE FINISH SURFA E - - QBAULJINSTALLED VALLEY PRECAST ITEM-150pT-3CP-ADV-P-HHj DEPTH TO TOP OF TANK FROM PROPOSED GFtddrTrMT17M.5^- - , 112.5 f _ 4" SCHD-40 PVO5EWER PIPE @ 296 P P- 4 • - . • 10.5' 1 • • • - INSTALLED ELECTRICAL WIRES IN CONDUIT FROM HOUSE - ELECTRIC SERVICE TO REMOTE CONTROL PANEL PROFILE PIT 4 + SL .ETC ETC - 4rSTALL D�I" 2 �f11AY CLEANOUT I i + 3- BEDROOM IRRIGATION WATER PIPELINE 10.0' FF EL=6129' INSTALLED 4" INSPECTION PORT W/ CAP SET AT FINISH l GRADE (TYP. EACH PROXIMAL CHAMBER ROW END CAP LOT 2 I I 1112" PVC SCHD-40 CUSTOM PERFORATED 1.5" PVC MANIFOLD W/ CONNECTIONS TO EACH 30.7' DISTRIBUTION LATERALS WJ 5132-INCH blq. PERFORATED DISTRIBUTION LATERAL I ...�./ ------ k ' ORIFICES EVERY 2.5-FEET ALONG PIPE. I 1.5" SCHD-4D TRANSPORT PIPE . 'r _ 1 1 EXTERNAL SPLICE BOX (TYP. I. P _ 5 U- .. _ : - - It PROFILE P 5 DRIVEWAY PLATTED BUILDING ENBVELOPE� i VA t x �PF300512 30GPM HIGH HEA TURBINE PUMP, SHP, 230V, PVU68-1819 81 UBE VAULT MF3P-45FS 48'-3 FLOAT ASS 45�T M- PF5o0512 5DGPM HIGH HEAD TURBINE PUMP, I,.SHP, 230V PVU68-1819 BIOTUBEVAULT 'fAF3P-45FS 48'-3 FLOAT ASSEMBLY 45" STEM t R16D.0 i WELL SETBACK'. =m x LOT C1 cri I RF'';HRDlVI;IC)N nF I CIT C RI OC'K 11 ��11111111111111111111111111111111111 MEMO �11i1111111i1111111i11111i1111111i1111VOL 11111111l1111111l111111111111111111111TOTAL "m11111i111111 ■■■111111111111111�i111111111111111111� CNiel ■��llfl111r111111111`Illlll111111 _ �:i1111111i11111111111111w1111111111NI - - �1l11111111111111111111111111�11111111NNMIN C11111111111r11111111■!11111111►r11111■PUMPRUNTIME ■■m11111111111111111i1�■■11111111111 11111 NINON 1111111111111 1111111111111111111111ir�1111111111 11111111111l111111111111111■ IiiiiiiiGiiliiiilii'■_==.:;i11111111111111111 11111111111l11l:i�1111111111111 Ili�l�llillilllllll■llllllll■ll i �' TREATED DISCHARGE TO DISPERSAL BED VOLUME FLOAT DOSING TOTAL■TRANSPORT .. ®� 111111111111111111111111111111loll'TOTAL ■ DISTRIBUTION PIPING loin ■ ` ®� PER ZON E QUAD 4 1111111lIIIIIIIIIIi1111111111111111l1 DR ®� 11111111111111111111111111111111f1111 VOL' DRN BACK 11 Bill III ■ • ■ •■ �� ■ �® 11111111111111110111111111111111111 STORAGE 3-COMP 00 GAIL TANK , 1111111l11l1111111111i►111111111111l111 "■ ■ 1SPREAD • imili 11 ■• ®® DESIGN PUMP, 111111111111111111l111111111�11111111■ 111111111111i111i111111131111111111NINE MIN PUMP TIME TO DELIVER DO �® • �® 111•••11111l111111111.:�IIIIrMi:1111111111l 11111l1111111111111s1r111lllllil■ ■ ■ ■• ■' " -■ ■ k Mj- ioi11l1�11111111111�11i1111111n� .: •:• . .. 111C!111111 11111�a1l1�11LL STAGE FROM- .i1 FLOAT LEVEL SET ■- 11�� 11■ FLOAT STAGE LEVEL SFROM ■• TOP OF Fl I TOP FLOAT TREE HIGH r r LEVEL INV IN -■ FLOAT HIL ALARM 1111111■ !� �"�w:MN11111111111111111111�111111111 ■ • P ON ■l■ll■in , �® TOP .filter ®� '1500 Gallon Top Seam - 3CP 15W-3CP%AWW Ad►►anTexTN1 Tank (2000 Total Goilom) oPgral sve�Es C12TI" p4 v+rr.r..onn twt v.r r.sT1F r.P .,I- - 3735 n• Yc ■ N day.; C-idral. - 5,0M P9 AM. . ienk to be set - s' m>,a..end had or pa..rosal a T.nit to bm boddlllM ua MV on dl .ldw In lift' !.- th.n 24 and me h-I-Ily cemparled a E--.tqd twW y W u r.r beddi• Prodded iar9. ednn- e .m.Kd El.laYation .hourd de dawoteree and I ��• mot' 7 I • �I tank fil.d rRh �A- prl.r W b.rnq - II put In -Ann far In. ldlatlan wlrb =Y !r kohl. 4- than P Wk. qr.d. UMLE 0844- l■ for reellr.s! .vet a uaaee iee.uaee al- ppe f)Nrvw.d eanpl.h xltl, Intend prpinq 1 _ PYC -I Included with .Y.L.,, ulnbrwn of 3 fwt - - it ` "I'"far AdronT.>s I"' Yrar�sl 1 lianirW Parrcl to a i.d M .1ghS (I .ne of Yea ZInn 4' m b-y d.pth hot rtiLUOWAJOL9 BURY Y■IW (a.- .. real- Tm.) iw= Twr 5 r r - r s _ r Fr1rPot a■ Y-.' a-r 10 ■1■1 Y-e' ! - if r-r K-p M r-v TOP VIA 31111 VkW sy.t"- '9' System. nere - adela-al b.eBr a 500 1 �dtan took Ta d6ch.rp. pump �-- • A 5yeteme ey ha.w add E1 ..I AW gdiu, took withm doNnp p>pfion . Complete .ystein.ro.atl.n aWlmie IYI .wn..rao. t�.,,11,■ Olg9ing Space invert OknenaTana Nat Copadky Not 1W L-q x e VJ4ra.! Out OuISItlk X CMW Op irh+el 54' T■O 23 WO VALLEY FWU T19-3953 WID FRWASTr I71C. W■Mft: www. dkgpreCartCom Huanx Bute, Golomdo Email: cam Yfelghl >Ndtn FMl Irdat Std. urea. OufYt TotalLtd Tank rota 1 qY" T9" f04" f01■ qdr 306 gall LM qd 2Ca■ 90115420 be1■HO W 2i■BO 6. 6" MIN. SELECT MATERIAL COMPACTED TO 95% 57AN DARD PROCTOR L'A -"-- BEDDING OF CLASS 6 AGGREGATE BASE 12" " COUR5E OR SUITABLE ONSITE MATERIA �..f 12" [- TRENCH CROSS-SECTION FOR PVC DR HOPE DRAIN LINES N.T.S. SET 4" INSPECTION PORT RISER PIPE ON END CAP OR END CHAMBER PRE FORMED PENETRATION SECURE WITH SHORT SCREWS THROUGH FLANGE INTO PIPE EXISTING GRADE UNDISTURBED EARTH SCREENED BACKFILL NATIVE 501E CHAMBER UNIT (SPRAY SHIELD) QUICK-4 PLUS LP CHAMBER PRESSURE DISTRIBUTION PIPE CONNECTED THROUGH END CAP TO 40 CUSTOM PERFORATED LATERAL PIPE SCARIFY LL BOTTOM SURFACE AND 10.01 x - x T 10 0 5 10 20 DCC1 IL]r1t'.IICinRI nc I �"•'-T I 41 r1r'V '1 ( 1N FEET) I inch = 10 ft. 4 (to scale) GRAPHIC SCALE RECIRCULATION BYPASS RETURN WITH BALL ALVE SET FOR 15% (8 GPM) EFFLUENT 0 2 a s 15 RETURN TO ANOXIC PRIMARY COMPARTMENT FILTRATE RETURN FROM RSV, ECIRCULATION SPITTER VALVE (RSV) { IN FEET) NLET TREATMENT TANK 1 inch = 4 ft. 4" GRAVITY EFFLUENT PIPE FROM 1000 GALLON SEPTIC TANK 2" P`O�VENT-,.,_ ET C ETC ETC ETC EqG 2" PVC POD DRAIN LINE T RSV ADVANTEX AX-20 POD �r�,�r��„ ,k,• 1.5" TO 1" PVC CONNECTION TO POD 3- SUPPLY MANIFOLD FROM RECIRCULATION DIRECT BURY ELECT & CNTR WIRES PUMP TRANPDRTPIPE I _ INSTALLED IN C bUIT i` 2" FILTRATE BRAIN PIPE FROM RSV `_ • -- . CONNECTING TO EXTERNAL SPLICE F. TO DOSING COMPARTMENT BOX FROM CONTROL ANEL. 1.5" RECIRCULATION TRANSPORT PIPE TO POD AND RETURN WITH BALL SALVE SET FOR 1536 �8 GPM) FILTRATE RETURN 15DD GAL 3-COMPARTMENT TREATMENT JbO51NG TANK 1.5" TRANSPORT PIPE TO 1.5" 5TA BED MANIFOLD ASSEMBLY PF300512 30GPM HIGH HEAD TURBINE PUMP,31 CROWN FIELD TRENCH TO 4" PVC INSPECTION PORT RISER DIVERT SURFACE WATER fi" VALVE 80X TOPSOIL SEED AND MULCH FINISH SURFACE 4" PUSH ON CAP %MAINTAINS ITABLE VEGETATIVE COVER .� 2a"-24'r 2--MIN. f 1.5" CHI]-40PVCDISTRMANIFOLD 1.5" TEE CONNECTION NATIVE SANDY SILT LOAM �I ­,' NOTE: EXCAVATION SIDE WALLS THE TREATED EFFLUENT DISPERSAL BED MUST BE LEVEL. INSTALL CHAMBERS WITH END CU5TUME PERFORATED PRESSURE PIPE WITH ORIFICES CAPS OVER SCARIFIED NATIVE 501E FOR USE AS SPRAY SHIELDS. INSTALL PERFORATED AT 12 O'CLOCK. SECURE PIPE WITH PUSH IN STAPLES DISTRIBUTION LATERALS ALONG LENGTH OF EACH CHAMBER ROW FROM A COMMON MANIFOLD PIPE CONNECTING EACH CHAMBER ROW. CUSTOM PERFORATED PIPE TO BE LAID ON NATIVE SOIL ABSORPTIVE SUFACE WITH ORIFICES ORIENTED UPWARD EXCEPTTHE FIRST AND LAST ORIFICES TO BE ORIENTED DOWNWARD. INSTALL A 4" VERTICAL INSPECTION RISER ON EACH CHAMBER END CAP FROM THE MOLDED END CAP PENETRATION FLANGE ON THE PROXIAMAL DISTAL ENDS OF EACH CHAMBER ROW. INSTALLA BALL VALVE AT THE END dFTHE DISTRIBUTION LATERAL ACCESSIBLE FROM THE INSPECTION PORT TO ALLOW FLUSHING OF THE LINE. THE VALVE 15 CLOSED FOR NORMAL OPERATION. PRESSURE DOSED NATIVE SOIL DISPERSAL BED SYSTEM WITH CHAMBER SPRAY SHEILDS .SHP, 230V, PVU68-1819 BIDTUBEVAULT MF3P-45FS 48'-3 FLOAT ASSEMBLY 45" STEM PF500512 56GPM HIGH HEAD TURBINE PUMP, .SHP, 230V PVU68-1819 810TUBE VAULT MF3P-45FS 48'-3 FLOAT ASSEMBLY 45" STEM TREATMENT SYSTEM COMPONENTS AND PLUMBING GENERAL NOTES: 1. THE OWTS A5 SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING. Z. THE PROPOSED LOT CONDITIONS BY 5OPR15 ENGINEERING 3. THE EXISITNG LOT CONDITIONS PER COUNTY G15 DATA BASE, AERIAL MAPPING, LIAR TOPOGRAPHY AND5URVEYINFORMATIdN BY5OPRI5 ENGINEERING LLC. 4. PRIMARY OWNER NAME & ADDRESS: KEITH BRAND, 50 Cedar 5t., Carbondale, CO 51623 S. LEGAL SUMMARY: SECTION: 22 TOWNSHIP: 7 RANGE: SS SUBDIVISION: COOPERTON TWNSTE. BLOCK:11 LOT: B 20313 SQUARE FEET. SUBJECT LOT Z RECEPTION #1007096. 6. SITE ADDRESS: 53 5 CEDAR STREET, CARBONDALE, CO 81523 7. PARCEL NUMBER: 23932$464002 S. LEGAL WATER SUPPLY: PROPOSED WELLTD SUPPLYTWO SINGLE FAMILY HOMES, 2 ADU'S, 4,000 5F LAWN. SUBJECT SITE 15 INCLUDED IN THE BASALT WATER CONSERVANCY DISTRICT PER CIVIL ACTION NO. 5593, AUGMENTED PER BWCD CONTRACT NUMBER: 3.3.5.811, MARCH I4, 3023 9. COUNTY OWTS PERMIT NO.. SEPT-9392 1 OPRIS ENGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970)744-03I1 FAX: [970}-704-0313 DESIGNED BY PER 07/15J25 DRAWN BY PER 12J07J25 Lot B-2, Design Calculations OWTS CHECKED BY YTN 1Z/08J25 The owners are applying for a building permit to construct a . The OVITS is designed as a level 3N treatment System with installation of an OWTS advanced treatment unit to allow for a smaller system footprint and DATE: 07-15-25 efficiently serve the 1200 S.F. 3-bedroom single family residence on Lot 2. Minimum population based on 3 bedrooms = 6 persons. Gallons per day per person =75 gal/person/day, JOB NO. 33149.01 Ln 0 Design flow (qd) gal/day = (# of people) x (avg. flow) gal/person/day. Design Flow qd = 6#75=450 gpd OWTS Components and Treatment Capacity per Regulation 43 design criteria The system is designed for demand dosing of advanced secondary treated effluent to a shallow pressure dosed chamber dispersal field bed, pursuant to Regulation 43 design criteria. The design includes a gravity service pipe from the proposed dwelling to a 1,500-gal concrete 3-compartment septic/Advantex treatment tank. The treatment tank will be equipped with Advantex treatment and operational components to provide advanced secondary treatment of the septic tank effluent. The treatment will include an AX-20 filter pod that has the capacity to treat effluent from an equivalent 3-bedroom residence or up to 600 gpd for residential wastewater strength .The treatment system will include all controls and Vericomm telemetry. The system will be maintained and service on a bi-annual basis by a qualified service provider. The upgraded OWTS is designed and intended to be operated in compliance with the County adopted OWTS Regulation 43 for higher level treatment systems. Septic Tank Design The septic tank capacity required for a minimum 48 hour retention time is calculated as follows: * V = 450 gal/day 2 = 900 gallons. Install new 1,500 gallon 3-compartment concrete Septic/Treatment Tank with Orenca Systems Advantex AX-20 treatment components. The first compartment chamber has a 1000 gallon capacity. The recirculation and dosing compartments each have a 500 gallon capacityfar a total tank Volume of 2000 gallons. � `" J" I Sub Surface Conditions and Testing � w A subsurface soil investigation and site assessment was performed by Sopris Engineering in on August 21, 2024. The soils in the proposed soil treatment areas (5TA) and adjacent building envelopes (5TA) were sampled and characterized by application of the USDA visual/tactile soil texture method analysis from samples in 5 profile pits on Lot B. No evidence of seasonal high ground water, redvx conditions or any other limiting condition was u J observed in the 3 applicable profile pits located on Lot Z. Groundwater levels are expected to be below 10 feet from the existing surface grades on the flat terrain. W Profile Pit-1 W The sails below approximately $inches of rocky gravelly topsoil consists of sandy silt loam texture sail with Long Term Acceptance Rate (LIAR): �00 Receiving Wastewater Treatment Level 3N; �•'eS� �. LTAR; [Table 10-1 Soil type 2 loading rate for a sandy silt loam is (1.1 gal./S.F./day); �R p Design Flow; Qd =flow (gal/day) = 450 gpd 28377 Loading factors; Table 10-2, Pressure application bed, L.F.1 - 1.0) � •�� 09 2025.�' a� Treated Effluent Soil Dispersal/Absorption Area ; A =Area S.F.; � a��r,• •.. ��-�� A(sfj = qd xA(sfj = 450 gpd xflNA►. LTAR 1.1 Gal/S.F./day 417zxxt'V Number of quick-4 Plus LP Infiltrator chambers 4`x3'x$"chambers: DATE REVISION 409 S.F. = 34 chambers; Use 36 chambers 12 S.F./Chamber Install 36 quick-4 Plus LP Infiltrator chambers in 4 rows 36' long by 3' wide with 9 chamber units per row plus two end caps as delineated on the plan. The treated effluent will be pressure distributed to a common manifold atthe proximal head of the chamber rows and for discharge to each perforated distribution lateral pipe in each chamber raw. TITLE oINTs AS -CONSTRUCTED RECORD DRAINING DRAWING N0. C-1