HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLCO-01-26-9642
FREEUP STORAGE SILT LLC
WATER TANK AND PUMPHOUSE TO SUPPLY HYDRANTS,
FIRE SPRINKLER, AND RESTROOM
357 S. 16T" STREET, SILT
1) THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS.
2) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS.
3) A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
HTTPS://WWW.COLQRADO.GOV/PACIFIC/DORA/DPO ELECTRICAL PLUMBING PP
RMITS
4) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE.
5) GEOTECHNICAL ENGINEER IS TO OBSERVE THE MICROPILE INSTALLATION AND
PROVIDE A STAMPED LETTER THAT THE PILES ARE INSTALLED PER
SPECIFICATIONS.
6) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED
PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE
CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILITY.
EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY
INSTALLATION OF NON -EROSIVE DOWN DRAINS OR OTHER DEVICES.
7) ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY A
LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE
OF THE CERTIFICATE OF OCCUPANCY.
8) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
9) ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE
INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO
BACKFILLING.
10) PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING
DEPARTMENT, WELDING AND BOLTING IS MINIMUM.
1 1) COMBUSTIBLE MATERIAL IS LIMITED IN TYPE I AND TYPE II CONSTRUCTION. SEE
IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS.
12)ALL EXTERIOR LIGHTING IS TO BE DOWNCASTAND SHIELDED.
13) ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP,
INCLUDING POCKET AND SLIDING DOORS. (ANSI A117.1-404.2.6)
14) UFER GROUNDS ARE REQUIRED TO BE INSPECTED AT FOOTING INSPECTION
15)ANY EXPOSED FOAM IS TO BE COVERED WITH AN IGNITION BARRIER OR A
THERMAL BARRIER BASED ON LOCATION. (IRC R316)
16) CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING
PLANTS AND SEEDS.
17) REVEGITATE ALL DISTURBED AREAS THAT ARE NOT PART OF A ROAD OR NON -
SEEDED AREA.
18) PROVIDE EROSION CONTROLS UNTIL SEEDED AREAS CAN BE ESTABLISHED.
19) PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION.
20) FOLLOW ENGINEERED PLANS. VERIFY ANY CHANGES WITH THE ENGINEER.
21) PROVIDE MEANS TO KEEP THE TANK AND PIPING FROM FREEZING.
22)ANY PLUMBING IS TO BE INSPECTED AND APPROVED BY THE FIRE DISTRICT.
23)THE PUMPHOUSE STRUCTURAL DRAWINGS ARE TO BE A DEFERRED SUBMITTAL,
NO INSPECTIONS ARE TO BE PERFORMED ON THE PUMPHOUSE UTIL APPROVED.
24)ANY REQUIREMENTS FROM THE FIRE DISTRICT BECOMES REQUIRED CONDITIONS
OF THE PERMIT.