HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLCO-01-26-9642 FREEUP STORAGE SILT LLC WATER TANK AND PUMPHOUSE TO SUPPLY HYDRANTS, FIRE SPRINKLER, AND RESTROOM 357 S. 16T" STREET, SILT 1) THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS. 2) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS. 3) A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. HTTPS://WWW.COLQRADO.GOV/PACIFIC/DORA/DPO ELECTRICAL PLUMBING PP RMITS 4) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE. 5) GEOTECHNICAL ENGINEER IS TO OBSERVE THE MICROPILE INSTALLATION AND PROVIDE A STAMPED LETTER THAT THE PILES ARE INSTALLED PER SPECIFICATIONS. 6) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILITY. EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY INSTALLATION OF NON -EROSIVE DOWN DRAINS OR OTHER DEVICES. 7) ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 8) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 9) ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO BACKFILLING. 10) PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING DEPARTMENT, WELDING AND BOLTING IS MINIMUM. 1 1) COMBUSTIBLE MATERIAL IS LIMITED IN TYPE I AND TYPE II CONSTRUCTION. SEE IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS. 12)ALL EXTERIOR LIGHTING IS TO BE DOWNCASTAND SHIELDED. 13) ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, INCLUDING POCKET AND SLIDING DOORS. (ANSI A117.1-404.2.6) 14) UFER GROUNDS ARE REQUIRED TO BE INSPECTED AT FOOTING INSPECTION 15)ANY EXPOSED FOAM IS TO BE COVERED WITH AN IGNITION BARRIER OR A THERMAL BARRIER BASED ON LOCATION. (IRC R316) 16) CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING PLANTS AND SEEDS. 17) REVEGITATE ALL DISTURBED AREAS THAT ARE NOT PART OF A ROAD OR NON - SEEDED AREA. 18) PROVIDE EROSION CONTROLS UNTIL SEEDED AREAS CAN BE ESTABLISHED. 19) PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION. 20) FOLLOW ENGINEERED PLANS. VERIFY ANY CHANGES WITH THE ENGINEER. 21) PROVIDE MEANS TO KEEP THE TANK AND PIPING FROM FREEZING. 22)ANY PLUMBING IS TO BE INSPECTED AND APPROVED BY THE FIRE DISTRICT. 23)THE PUMPHOUSE STRUCTURAL DRAWINGS ARE TO BE A DEFERRED SUBMITTAL, NO INSPECTIONS ARE TO BE PERFORMED ON THE PUMPHOUSE UTIL APPROVED. 24)ANY REQUIREMENTS FROM THE FIRE DISTRICT BECOMES REQUIRED CONDITIONS OF THE PERMIT.