HomeMy WebLinkAboutEngineer's Framing Detail1/4" GAP TIGHT FIT (GLUE) JOIST FLANGE WIDTH WEB STIFFENER THICKNESS NAILING REQUIREMENTS 3/4"2. 1/16"EIGHT 8D NAILS MIN (DRIVEN FROM EITHER SIDE)7/8"2. 5/16" 1" FOR 2. 5/16" + 2. 1/16" WIDE JOISTS PACKOUT DETAIL @ FACE MOUNT HANGERS SIMPSON IUS or ITS HANGER PROVIDE 12" LONG WEB PACKOUT N/S + F/S IN THIS MEMBER BACKER BLOCKING FASTENING SCHEDULE 1. 3/4" x 11. 7/8" SINGLE LVL HEADER NOTES: 1. WEB BACKER BLOCKING SHALL BE CUT FROM STRUCTURALLY RATED OSB OR PLYWOOD PANELS 2. IUS HANGERS ARE PERMITED IN CONDITIONS WHERE LVL HEADER IS ADDED AFTER SUBFLOOR IS INSTALLED. 3. ALL FLOOR FRAMING MEMBERS MUST BE SECURLY FASTENED TO FLOOR SHEATHING W/ TOP-DOWN 8D NAILS @ 6" O.C. MAX SPACING. 4. HANGER ATTACHMENT NAILS DO NOT COUNT AS BLOCKER NAILS. SIMPSON ITS1.81/11.88 HANGER EA. END OF LVL PACKOUT DETAIL @ TOP FLANGE HANGERS CINCH ASSEMBLY TOGETHER TYP. MAX JOIST LENGTH = 14 FT. DO NOT EXCEED 1/4" GAP TIGHT FIT (GLUE) From:John Hendricks To:Brooke Winschell; Teresa Bianco Subject:FW: Coon Residence Date:Monday, February 9, 2026 3:08:23 PM Attachments:image.png image.png image001.png Engineer framing detail Permit#9348 John Hendricks Building Inspector Community Development Department Jhendricks@garfieldcountyco.gov Phone- 970-945-1377 ext. 1461 108 8th St, Suite 401 | Glenwood Springs, CO 81601 From: Aaron Higgins <aaron@jm-co.org> Sent: Monday, February 9, 2026 1:20 PM To: Matt Provost <mprovost@garfieldcountyco.gov>; John Hendricks <jhendricks@garfieldcountyco.gov> Cc: James Martinez <james@jm-co.org> Subject: Fwd: Coon Residence You don't often get email from aaron@jm-co.org. Learn why this is important Matt & John, Here is Mic's approval for the holes drilled in the floor joists at the front entrance. Thank you, ---------- Forwarded message --------- From: M B <studiom.engineer@gmail.com> Date: Thu, Feb 5, 2026 at 11:29 AM Subject: Re: Coon Residence To: Aaron Higgins <aaron@jm-co.org>, James Martinez <jmartinez@martinezwestern.com> This 3 inch hole in each of these joists will be acceptable because the 11. 7/8" BCI 6000 1.8 joist (16 inches on center) has the capacity to span the entire joist length without considering the center bearing wall as a bearing point. Per the BCI hole schedule for 11. 7/8" I joists, we can have a 3 inch dia. hole so long as we are no closer than 1 ft 7 inch from an END bearing support. We are more like 6 ft from the end reaction, so we are good. On Wed, Feb 4, 2026 at 6:37 PM Aaron Higgins <aaron@jm-co.org> wrote: Hey Mic, We ran into another issue at the Coon Residence. The electrician drilled a 3 inch hole through the floor joists clouded below. I included some photos in the attached with some measurements (3 inch diameter hole, approximately 6 inches to center of each hole). Let me know if you want to get on the phone tomorrow to discuss or if you need any additional information or photos. Thank you, -- Michael "Mic" Baca, P.E. Studio M Engineers, LLC 970-366-8690 cell