HomeMy WebLinkAboutSupplemental Application MaterialsUELS, LLC
Corporate Office * 85 South 200 East
Vernal, UT 84078 * (435) 789-1017ENGINEERING & LAND SURVEYING
CHEVRON U.S.A., INC.
Identification & Location Key
Directions to Site:
SKR 698-10-BV PAD
SITE PLAN
DeBEQUE
4.
1
M
I
.
+
/
-
1
2
.
5
M
I
.
+
/
-
10
0
'
50
'
0'
EXISTING LOCATION:
SKR 698-10-BV PAD
CL
E
A
R
C
R
E
E
K
R
D
C
O
U
N
T
Y
R
D
2
0
4
INT
E
R
S
T
A
T
E
7
0
T7S
T6S
GARFIELD CO.
MESA CO.
R
98
W
R
97
W
COUNTY RD 200
CO
U
N
T
Y
R
D
2
1
3
CR
2
0
4
COUNTY RD 202
T8S
T7S
T8S
T6S R
97
W
CR 211
Housing Facility 1 - SKR 698-10-BV PAD
SWSW (TRACT 72), Section 10, T6S, R98W, 6th P.M.
& NWNW Section 15, T6S, R98W, 6th P.M.
GARFIELD COUNTY, COLORADO
NAD 83: Lat/Long: 39.540312, -108.321827
Parcel #2137-321-00-0008
85 South 200 East
Vernal, Utah 84078
o: 435.789.1017.
x: 435.789.1813
www.uintahgroup.com
1
Inspection Report for: SKR 698-10-BV – Small Temporary Employee Housing
Prepared for: Chevron U.S.A., Inc.
Location: Section 15, T6S, R98W, 6th P.M.
Conducted By: Sterling Walker, P.E.
Date Conducted: May 7, 2026
Paragraph Article 7-707 Land Use and Development Code (7/15/13)
Reference Characteristic or Standard Description Inspection Comments
A.
Within 48 hours following occupation of the Small Facility,
documentation shall be provided to the Community
Development Department, Sheriff’s Office, and relevant fire
protection district(s) that demonstrates and certifies
compliance with the following standards. Notice shall also be
provided to these entities within 48-hours following removal
of a Small Facility.
Not subject to visual inspection and certification by third party
Professional Engineer.
B.
General Information requirements
Not subject to visual inspection and certification by third party
Professional Engineer.
C. Small Facilities shall comply with all applicable Federal, State
(i.e. Building Codes and electrical permits), and local laws and
regulations (i.e. fire code), but are not subject to County
Building Permit.
Colorado Division of Housing certifications noted on Safety Shack
trailer, Certification No.26657; Company Man trailer, Certification
No. 25952; Tool Pusher trailer, Unit ID. RM200330 with
Certification No. 22496 manufactured by DBI Welding Fabrication
in 2009; MWD building, Certification No. 24705. All other aspects
not subject to visual inspection and certification by third party
Professional Engineer.
D. Water systems shall comply with standards set forth in
section 7-705.B.
The site is using pallets of bottled water for their potable water
needs.
2
E. Wastewater systems shall comply with standards set forth in
section 7-705.C.
Wastewater disposal at the permitted site will be a vault-and-haul
system. Two 2000-gallon sewage holding tanks are onsite for an
aggregate containment of 4000 gallons. Sewage flows estimated to
be 600 gallons/day (8 individuals x 75 gpcd). Sewage holding tanks
need to be emptied approximately every 7 days (4000 gallons /
600 gallons per day). Wastewater vaults equipped with overflow
alarm device.
F.
Each Small Facility shall be maintained in a clean, safe, and
sanitary condition, free of weeds and refuse. Any hazardous
or noxious materials that must be stored at the Small Facility
for operational or security reasons must be managed in
accordance with all applicable Federal, State, and local laws
and regulations.
Site appeared to be maintained in clean, safe and sanitary
condition, free of weeds and refuse.
G.
Wildlife-proof refuse containers must be provided for trash.
Outdoor food storage is prohibited unless facilities are
provided that prevent the attraction of animals to the Major
Facility site.
One wildlife-proof trash receptacle with a capacity of
approximately 30 cubic yards onsite. Individual refuse containers
in each office/housing structure.
H.1 Provisions for giving alarm in case of fire and fire suppression
must be installed per fire codes and as required by the fire
protection district.
Smoke detectors and fire extinguishers (ABC-rated) located in all
factory built non-residential structures living quarters.
H.2
Single-station carbon monoxide alarms must be placed in
each Manufactured Home or Recreational Vehicle unit.
Single-station carbon monoxide detectors located in factory built
non-residential structures sleeping trailers.
I.
Domestic animals are prohibited.
No domestic animals observed on-site.
J.
The Operator shall obtain a certification inspection
conducted by a qualified professional engineer. The
certification shall verify that at the time of inspection the
identified Small Facility meets or exceeds the requirements of
this section.
This inspection was conducted by a qualified Professional
Engineer licensed in Colorado and certifies compliance with
applicable standards set forth in Article 7.707 of the Land Use and
Development Code (1/4/23), as amended, that are subject to
visual inspection.
3
Professional Engineer’s Attestation
I hereby attest that I am a Licensed Professional Engineer in the State of Colorado. I attest that I or my agent
have conducted a visual inspection of the Small Facility identified in this Checklist, as installed, and, based on
information from that inspection I certify that the Small Facility complies with the standards, subject to and
limited to visual inspection items as identified above; set forth in Article 7-707 of the Land Use and
Development Code (Effective 1/5/23), for Garfield County, Colorado.
PE Certification Number: No. 52113 (Colorado) PE Stamp
Date of Inspection: May 7, 2026
Print Name and Title: Sterling Walker, P.E.
Signature: