Project Address: 1711 County Road 331, Silt, CO 81652 Parcel No.: _217916400490
Owner Name: Alicia & Andrew Frantz Owner Phone: (970) 945-2872
Inspector: Goblin Septic Inspector Phone: (970) 319-2268
Number of Bedrooms: 3 Minimum Tank Capacity: 1000-gallons Minimum Absorption: N/A ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-9811_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _05/18/2026____________________ Expiration Date_05/18/2027_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with scope of work and site plan as
submitted by Andrew Frantz May 8, 2026. Changes to the design and permit must be approved by
Garfield County Public Health prior to construction.
The existing OWTS will serve a new 3-bedroom manufactured home. A new 4-inch sewer line
constructed of SDR 35 pipe, or pipe of equivalent or greater strength, will tie into the existing sewer
line. All existing sewer line must be found in good condition replaced. A cleanout must be installed
in the sewer line upstream of the septic tank. An existing 1000-gallon two compartment septic tank
set level with access to grade has been found to be in good working order and will remain in use.
Garfield County Public Health recommends that an effluent filter be installed in the outlet of the
septic tank. Effluent will gravity flow to the existing STA that has been found in good working order
and is documented in ISDS permit # 3201, designed and permitted for 3-bedrooms in 1999. Maintain
all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
05/18/2025
Issued By: Garfield County Environmental Health
Department
Date