HomeMy WebLinkAboutEngineer's OWTS Alteration Plan*IMPORTANT NOTE*
BLACK CANYON ENGINEERS AND GARFIELD COUNTY TO BE
PRESENT FOR INSPECTION BEFORE SYSTEM IS COVERED.
NOTIFY MIN. 5 BUSINESS DAYS IN ADVANCE
DISTANCES BETWEEN FEATURES
ARE APPROX., PROVIDED FOR REF.
& SHOULD BE VERIFIED BY SURVEY
RELATIVE ELEVATION INFORMATION - VIF
ITEM.
PROPOSED ELEVATION
OUTLET FROM
HOUSE
100'-0"
PIPE INVERT
99'-6"
TANK OUTLET
99'-3"
TANK BOTTOM
(INSIDE)
957„
MANIFOLD
97'-0"
INFILTRATIVE
96'-4"
SURFACE
Q
w
q
ENTIRETY OF LOT NOT SHOWN FOR CLARITY L
DOUBLE SWEEP CLEANOUT WITHIN 5' OF BLDG.-
5' MIN. SETBACK FROM BLDG. TO SEPTIC TANK -
PROPOSED ELECTRICAL LINE -
PROPOSED
DETACHED
GARAGE
PROPOSED 5 BDRM. HOUSE
13
5'
24
4" DIA. SCH. 40 PVC,
MIN. 2% SLOPE,
FROM BLDG. TO TANK
E E
-SEPTIC TANK,
1,500 GAL. MIN.
L4" DIA. SDR 35 PVC,
MIN.1% SLOPE,
FROM TANK TO S.T.A.
F
+I
1
I
1
+ 1
1
+1
I
+ I
1
F
1
+
I 1
+ 1
E
I
+I
1
+1
I V)
O ,
O
I Z
�
0
I
O
LL
5 HOLE D-BOX
+
I X
W/ RISER
I
10
Z
+
1�
0
SLEEVE
I
1 Q
U
CONVEYANCE LINE
W/ SCH. 40 PVC PIPE, +
1
(5' EACH SIDE OF
CROSSING)
+
I
+I
+
+ I
I
I
[4'MIN. SEPARATION +
PARCEL 1f-239119400051 N/ G / BETWEEN EACH TRENCH
(16.00 ACRES) PROPOSED GAS LINE F
0 50' 100' PROPOSED WATER LINE PROPOSED ELECTRICAL MAIN 10' PROPERTY LINE SETBACK
SETBACK DISTANCES FROM SEPTIC TANK, H.L.T. UNIT, DOSING TANK, VAULT, GARFIELD SETBACK DISTANCES FROM SOIL TREATMENT AREA, GARFIELD COUNTY (06/18/18):
COUNTY (06/18/18):
SPRING, WELLS, SUCTION LINES, CISTERNS - 100 FT
SPRING, WELLS, SUCTION LINES, CISTERNS - 50 FT POTABLE WATER SUPPLY LINE - 25 FT
POTABLE WATER SUPPLY LINE -10 FT STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 20 FT
STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5 FT STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 10 FT
STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5 FT PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH-10 FT
PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH-10 FT SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA- 25 FT
SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA-10 FT LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND- 50 FT
LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND - 50 FT
SEPTIC TANK, DOSING TANK, VAULT OR PRIVY - N/A SEPTIC TANK, DOSING TANK, VAULT OR PRIVY- 5 FT
PROPOSED S.T.A.,
(4) TRENCH, 3' X 100'
25 CHAMBERS PER TRENCH
100 CHAMBERS TOTAL
PROTECT FROM DISTURBANCES,
COMPACTION, OR DAMAGE BY MEANS
OF STAKING, FENCING, POSTING, ETC.
W
G
INSPECTION PORT (8 TOTAL)F
4" DIA. PVC SOLID PIPE W/ CAP.
INSTALLED AT FIRST & LAST
CHAMBER IN EACH TRENCH
BLACK CANYON
ENGINEERS
LlcF
�6�1PDO
\Z H RCiO�N`fF�G
v0
55066 n
1)
OWNER/BUILDER/CONTRACTOR TO VERIFY
ACCURACY OF SEPTIC (O.W.T.S) PLANS WITH
ARCHITECTURAL & OTHER PLANS AND NOTIFY
ENGINEER OF ANY DISCREPANCIES PRIOR TO
EXCAVATION, CONSTRUCTION OR MATERIALS
PURCHASE.
2)
THE ENGINEER SHALL BE NOTIFIED A MINIMUM
OF 5 BUSINESS DAYS IN ADVANCE VIA EMAILAT
INSPECTIONS@BLACKCANYON
ENGINEERS.COM FOR INSPECTION AS PER
NOTES ON PAGE SP2.
3)
THE ENGINEER SHALL BE NOTIFIED IF ADVERSE
OR POOR SOIL CONDITIONS OR WATER ARE
ENCOUNTERED UPON EXCAVATION. FURTHER
ENGINEERING MAY BE REQUIRED
4)
VALID, ORIGINAL DOCUMENT ONLY WITH
EMBOSSED, SIGNED SEAL
5)
ALL NOTES & REQUIREMENTS FROM PAGE SP2
APPLY TO PAGE SPi
6)
ALL MEASUREMENTS TAKEN WITH BASIC
COMPASS, RECREATIONAL LASER RANGE
FINDER & GPS. ACCURACY IS LIMITED TO THAT
OFFERED BY STATED INSTRUMENTS
7)
STATED DIMENSIONS TAKE PRECEDENT OVER
MEASURED/SCALED DIMENSIONS
8)
TOTAL PAGES: 2
SIZE: ANSI D ("22 X 34")
REV.
DESCRIPTION
DATE
Firm Name and Address
Black Canyon Engineers
222 S Park Ave.
Montrose, CO 81401
970-568-5391
Support@BlackCanyonEngineers.com
www.BlackCanyonEngineers.com
Project Name and Address
Edinger OWTS
Parcel #239119400051
Carbondale, CO 81623
Garfield County, CO
Single Family Residence
Project Sheet
BCE122403 spi
Date02/11/25
Scale As Noted
GENERAL NOTES:
1) DESIGN AND OVERALL CONSTRUCTION INCLUDING COMPONENTS SHALL CONFORM TO THE REQUIREMENTS OF
GARFIELD COUNTY, CO. REG. 43, THE N.E.C. & THE COLORADO PLUMBING CODE.
2) LOCATE ALL EXISTING UTILITIES AND CONFIRM THAT ALL SETBACKS REQUIRED BY GARFIELD COUNTY & THIS DRAWING
CAN BE SATISFIED PRIOR TO EXCAVATION, CONSTRUCTION OR MATERIALS PURCHASE.
3) PVC PIPE TO BE EQUIVALENT TO OR GREATER THAN STRENGTH AS PER ASTM D3034 FOR UN -PERFORATED &
EQUIVALENT TO OR GREATER THAN STRENGTH AS PER ASTM D2729 FOR PERFORATED PIPE. ALL ANGLED PIPE
CONNECTIONS ON SOLIDS LINES SHALL BE 45 OR 22.5 DEGREE ONLY.
4) SEPTIC TANK SHALL BE A TWO COMPARTMENT TANK WITH A SEALED TANK BAFFLE, MANUFACTURED BY A COLORADO
DPHE APPROVED MANUFACTURER THAT MEETS REQ'S OF GARFIELD COUNTY & CO. REG. 43. FOLLOW ALL MFG.
INSTRUCTIONS & MAINTENANCE REQS. LEVEL GRADE AND PROOF COMPACT OR BED BOTTOM OF EXCAVATION TO ENSURE
LEVEL AND STABLE INSTALLATION OF TANK.
5) TANK SIZES SPECIFIED HEREIN ARE BOTH NOMINAL AND MINIMUM. FOR SYSTEMS WHERE A PUMP IS PLACED IN THE
TANK, OWNERIINSTALLER TO VERIFY THAT SELECTED TANK HAS SUFFICIENT EXCESS VOLUME SO AS TO NOT GO BELOW
THE MINIMUM SIZE WHEN THE PUMP VOLUME IS SUBTRACTED OUT.
6) IF A PLASTIC (POLY)TANK IS USED, THE BRAND OF TANK SHALL BE INFILTRATOR, ORENCQ, OR NORWESCO. IFTHE
SYSTEM INCLUDES A PUMP,THE PUMP SHOULD BE PLACED IN A SEPARATE DOSING TANK FOLLOWING THE MAIN TANK AND
NOT THE SEPTIC TANK.
7) IF A PLASTIC (POLY) TANK IS USED, OWNERANSTALLER SHALL ANCHOR TANK DOWN DUE TO BUOYANCY CONCERNS.
FOLLOW ALL MFG: S INSTRUCTIONS.
8) FOLLOW ALL COMPONENT (D-BOXES, EFFLUENT FILTERS, PUMPS, FLOATS, CONTROL PANELS, ETC.) MFG: S
INSTRUCTIONS INCLUDING LEVEL PLACEMENT& CODE COMPLIANCE WHERE APPLICABLE.
9) FOR PRESSURE DIST. SYSTEMS: FLOW, MEASURED VIA WATER SQUIRT HEIGHT, MUST BE MADE EQUAL BETWEEN
LATERALS BY FLOW EQUALIZING/ THROTTLING VALVES IN MANIFOLD. A 30-72"OPERATING HEAD (OR EQUIV. SQUIRT
HEIGHT) MUST BE AT DISTAL END OF LATERALS. INSTALLER MUST PROVIDE PHOTOS TO ENGINEER VERIFYING SUCH. ENSURE
ALL LIQUID DRAINS TO FIELD OR BACK TO TANK SO AS TO PREVENT FREEZING OF LINE. FLOAT POSITIONS & SYS. CONFIG. BY
OTHERS, EFFLUENT FILTER MUST BE INSTALLED BEFORE ANTI SIPHON VALVE WHEN S.T.A. ELEVATION IS BELOW PUMP
ELEVATION.
10) ALL CONVEYANCE LINES PRIOR TO THE SEPTIC TANK SHALL HAVE 1 DOUBLE SWEEP CLEANOUT W/RISER EVERY 100' IN
ADDITION TO THE ONE REQUIRED WITHIN S OF THE BUILDING.
11) INFILTRATIVE SURFACE TO BE LEVEL, U.N.O. MAX DEPTH IS 4 FT.
12) SEED THE FINISHED SURFACE OF LEACH FIELD AND DISTURBED SOIL AREAS AFTER CONSTRUCTION.
13) GRADE GROUND AROUND SEPTIC SYSTEM SO AS TO DIVERT WATER AWAY FROM THE STA. ROLLING, HYDRAULIC
COMPACTION & MACHINE TAMPING NOT PERMITTED.
14) PERMIT SET ONLY; NOT TO BE USED FOR CONSTRUCTION OR MATERIALS PURCHASE.
15) PRIOR TO CONSTRUCTION, SUBMIT ALL APPLICATIONS, PAY ALL FEES, AND OBTAIN THE PROPER PERMITS FROM
GARFIELD COUNTY.
16) SUBMIT ACLEAR AS -BUILT DRAWING OF THE ACTUAL CONSTRUCTION TO THE ENGINEER AT COMPLETION. THIS SHALL
INCLUDE DIMENSIONAL TIES TO THE SEPTIC TANK CLEANOUTS AND TO AT LEASTTWO CORNERS OF THE S.T.A. THERE SHALL
BE TWO TIES TO EACH POINT, REFERENCED TO PERMANENT FEATURES ON THE SURFACE SUCH AS CORNERS OF THE
BUILDING.
17) THE ENGINEER, WITH 5 BUSINESS DAYS NOTICE VIA EMAIL AT INSPECTIONS@BLACKCANYONENGINEERS.COM, WILL
MAKE FIELD OBSERVATIONS OF THIS WORK. THE FOLLOWING OBSERVATIONS WILL BE REQUIRED:
A. AFTER INSTALLATION OF DISTRIBUTION SYSTEM, LEFT EXPOSED TO CONFIRM LEVEL CONSTRUCTION WITHIN 1"
MAXIMUM TOLERANCE.
18) AT ANY POINT DURING INSTALLATION IF THE INSTALLER ENCOUNTERS A SOIL HORIZON, GROUNDWATER DEPTH, OR
BEDROCK DEPTH THAT DIFFERS FROM THAT SHOWN ON THIS DRAWING, NOTIFY E.O.R.
19) ALL SYSTEM PIPING, EXCEPT FOR DISTRIBUTION LATERALS WITHIN THE S.T.A., MUST BE BEDDED WITH SELECT
MATERIAL BEFORE FINAL INSPECTION BY LOCAL PUBLIC HEALTH AGENCY. SELECT MATERIAL MUST CONSIST OF LOOSE,
GRANULAR MATERIAL, FREE FROM STONES, CLODS, FROZEN SOIL, OR OTHER DELETERIOUS MATERIAL. BEDDING MATERIAL
MUST BE MECHANICALLY COMPACTED TO SUPPORT PIPING.
DESIGN FLOW CALCULATIONS:
5 BEDROOM HOUSE: OCCUPANCY = 8 PERSONS
8 PERSONS X 75 GAL./PERSON/DAY = 600 GAL./DAY
(GARFIELD COUNTY BEGS., TABLE 6-1)
SEPTIC TANK SIZING:
5 BEDROOM HOUSE =1,500 GALLON MINIMUM SIZE
(GARFIELD COUNTY REGS., TABLE 9-1)
SOIL TREATMENT AREA SIZING:
LONG TERM ACCEPTANCE RATE IS BASED ON SOIL OBSERVATIONS IN THE VICINITY OF THE
PROPOSED LOCATION OF THE SOIL TREATMENT AREA. SOIL IS CLASSIFIED AS SOIL TYPE 3,
CLAY LOAM. A LONG TERM ACCEPTANCE RATE (LTAR) OF 0.35 GAL/DAY/FT' IS APPROPRIATE
FOR THIS TYPE OF SOIL (GARFIELD COUNTY REGS., TABLE 10-1).
AREA REQUIRED = DESIGN FLOW/LTAR = 600 GPD/0.35=1,714.285714 SQ. FT.
SIZE ADJUSTMENT FACTOR FOR APPLICATION TO GRAVITY TRENCH:
1,714,285714 SQ, F.T. X 1.0=1,714.285714 SQ. FT. (GARFIELD COUNTY REGS., TABLE 10-2)
SIZE ADJUSTMENT FACTOR FOR APPLICATION VIA CHAMBERS
1,714.285714 SQ. FT. X 0.7 =1,200 SQ. FT. (GARFIELD COUNTY REGS., TABLE 10-3)
EACH STANDARD CHAMBER IS 12 SQ. FT.;1,200 SQ. FT. / 12 SQ. FT. =100 SO USE 100 CHAMBERS
(4) TRENCH, 3 FT. X 100 FT., 25 CHAMBERS PER TRENCH PLUS INLET/OUTLET ENDS
PROFILE TEST PIT LOG:
NOT TO SCALE
TYPICAL PROFILE - WEB SOIL SURVEY
FEET
o (0'-5") LOAM
(5"-6.5) CLAY LOAM
2
a
4
6
6
DEPTH TO RESTRICTIVE FEATURE/WATER TABLE, > 6.5'
7
8
9
10
SETBACK DISTANCES FROM SEPTIC TANK, H.LT. UNIT, DOSING TANK, VAULT, GARFIELD
COUNTY (06/18/18):
SPRING, WELLS, SUCTION LINES, CISTERNS - 50 FT
POTABLE WATER SUPPLY LINE -10 FT
STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5 FT
STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS- 5.FT
PROPERTY-LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH-10 FT
SUBSURF, DRAIN, INT. IRRIGATION LATERAL, DRY GULCH, CUT BANK, FILL AREA-10 FT
LAKE,WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND - 50 FT
SEPTIC TANK, DOSING TANK, VAULT OR PRIVY - N/A
SETBACK DISTANCES FROM SOIL TREATMENT AREA, GARFIELD COUNTY (06/18/18).
SPRING, WELLS, SUCTION LINES, CISTERNS -100 FT
POTABLE WATER SUPPLY LINE - 25 FT
STRUCTURE W/ BASEMENT, CRAWL SP. OR FOOT. DRAINS- 20 FT
STRUCTURE W/O BASEMENT, CRAWL SP. OR FOOT. DRAINS-10 FT
PROPERTY LINES/EASEMENTS, PIPED OR LINED IRRIGATION DITCH-10 FT
SUBSURF. DRAIN, INT. IRRIGATION LATERAL, DRY GULCH., CUT BANK, FILL AREA- 25 FT
LAKE, WATER COURSE, IRRIGATION DITCH, STREAM, WETLAND- 50 FT
,SEPTIC TANK, DOSING TANK, VAULT OR PRIVY- 5 FT
SLOPE GROUND AWAY
FROM RISER (TYP.)
FROM HOUSE
INFILTRATOR WATER TECHNOLOGIES QUICK4 STANDARD CHAMBER
HOME GRAVITY TRENCH CONFIGURATION
100 CHAMBERS TOTAL IN 4 TRENCHES, EACH 1001 LONG
om (NOT TO SCALE)
DOUBLE SWEEP CLEANOUT WITHIN 5' OF THE BUILDING
4" DIA. SCH. 40 PVC PIPE, MIN. 2% SLOPE, FROM BLDG. TO TANK
(INSULATE TOP OF CONVEYANCE LINE W/ 2" RIGID FOAM SUITABLE FOR BURYING)
1,500 GAL. MIN., TWO COMPARTMENT SEPTIC TANK.
COVER TOP W/ 4" RIGID FOAM SUITABLE FOR BURYING
as a
a
5' MAX.
5' MIN.
4" DIA. SDR 35 SOLID PVC PIPE, MIN. 1% SLOPE, FROM TANK TO S.T.A.
(INSULATE TOP OF CONVEYANCE LINE W/ 2" RIGID FOAM SUITABLE FOR BURYING)
GARFIELD COUNTY REGS., 43.10.F.6.E
THE TOP OF INSPECTION PORTS MAY BE
TERMINATED BELOW THE FINAL GRADE IF EACH IS
HOUSED IN A COMPONENT SUCH AS A VALVE BOX
FOR A LAWN IRRIGATION SYSTEM AND HAS
A REMOVABLE COVER AT THE GROUND SURFACE.
34"
(36" WIDE TRENCH)
SYSTEM MAINTENANCE:
IT IS RECOMMENDED TO MINIMIZE KITCHEN DISPOSAL
USAGE, INTRODUCE NO FOREIGN CHEMICAL
COMPOUNDS, CONSERVE WATER USAGE AND TO HAVE
THE SEPTIC TANK PUMPED, THE SYSTEM INSPECTED &
MAINTAINED EVERY YEAR. ALL MAINTENANCE IS THE
RESPONSIBILITY OF THE OWNER. WITH PROPER CARE
AND MAINTENANCE THIS SYSTEM SHOULD LAST MANY
YEARS. IF YOU HAVE ANY QUESTIONS OR CONCERNS
ABOUT YOUR SYSTEM PERFORMANCE OR MAINTENANCE,
CONTACT A LICENSED SEPTIC PROFESSIONAL.
INLETTEE
No te:
Test for water tightness via
vacuum or leakage test at
all connections
to tank, risers, lids, etc.
TYPICAL SEPTIC TANK
NOT TO SCALE
AS CONDITIONS
REQUIRE
1,500 GALLON MIN.
2 COMPARTMENT
SEPTIC TANK
TANK BAFFLE
24" MIN
nlle
'MIN.
NATIVE BACKFILL
TWO COMPARTMENT SEPTIC TANK OF SIZE SPECIFIED HEREIN.
LEVEL GRADE AND PROOF COMPACT OR BED BOTTOM OF EXCAVATION
TO ENSURE LEVEL AND STABLE INSTALLATION
4" DIA. SDR 35 SOLID PVC PIPE
4" DIA. SDR 35 SOLID PVC PIPE
4" DIA. SDR 35 SOLID PVC PIPE
4" DIA. SDR 35 SOLID PVC PIPE
INFILTRATOR WATER TECHNOLOGIES
QUICK4 STANDARD CHAMBER
TYPICAL TRENCH' DETAIL
SECTION VIEW
(NOT TO SCALE)
(36" WIDE TRENCH)
INSPECTION PORT TO BE INSTALLED AT FIRST
AND LAST CHAMBER IN EACH TRENCH (TYP.)
(EXT. ABOVE GRADE)
�A 9 ...
n v v v n v .. . v n �r v v a v l
iil IGG) (ii) lol lu) liil IGGI I it (Gil IGi) (Gil (Gil IiGI (Gil IGiI
IG GG [�7 GG GG i :1 GG' d GG GG ! J GG [�l, GG GG
u u u u u I Y Y Y Y Y I
5 HOLE D-BOX WITH RISER
STANDARD CAPACITY
CHAMBERS
100'
25 CHAMBERSRS PER TRENCH -
PLUS INLET/OUTLET ENDS
TOPSOIL
'MIN. 34" I- 4' MIN. I 34"
(36" WIDE TRENCH) (36" WIDE TRENCH)
ALL SYSTEM PIPING, EXCEPT FOR DISTRIBUTION LATERALS WITHIN THE SOIL
TREATMENT AREA, MUST BE BEDDED WITH SELECT MATERIAL BEFORE FINAL
INSPECTION BY THE LOCAL PUBLIC HEALTH DEPARTMENT. SELECT BEDDING
MATERIAL MUST CONSIST OF LOOSE, GRANULAR MATERIAL, FREE FROM STONES,
CLODS, FROZEN SOIL, OR OTHER DELETERIOUS MATERIAL. SELECT MATERIAL
MAY CONSIST OF ON -SITE JOB EXCAVATED OR IMPORTED MATERIAL. BEDDING
MATERIAL MUST BE MECHANICALLY COMPACTED TO SUPPORT PIPING.
ATANY POINT DURING INSTALLATION IFTHE INSTALLER ENCOUNTERS
A SOIL HORIZON, GROUNDWATER DEPTH, OR BEDROCK DEPTH THAT
DIFFERS FROM THAT SHOWN ON THIS DRAWING, NOTIFY E.O.R.
INSULATED FIBERGLASS GASKETED LID W/
STAINLESS STEEL BOLTS. OSI MOD. #FL24GV.
USE FL30GV IN MANHOLES > 2' DEEP
PVC RISER OSI MOD. #RR24 x 30"± W/
GROMMET(S). (BOND TO TANK ADAPTER W/
RECOMMENDED ADHESIVE OR EQUIVALENT)
MUST BE WATERTIGHT
SET RISER ADAPTER IN RAM -NECK
OR MASTIC ADHESIVE SEALANT
EFFLUENT DISCHARGE TO S.T.A. -1% MIN SLOPE
INSTALL POLYLOK EFFLUENT SCREEN OR NSF
CERTIFIED EQUIVALENT
VAULT INLET PORT
FINISHED GRADE
SOIL TREATMENT AREA (S.T.A.)
SEE DETAIL & SECTION HEREIN
SCARIFY SURFACE OF IN -SITU SOIL &
AVOID COMPACTING WITH EQUIPMENT (TYP.)
TOP VIEW
1% MIN SEPTIC TANK OF
�.----- MIN. SIZE
SPECIFIED
HEREIN
4" SDR 35 PVC SOLID PIPE
FROM TANK TO S.T.A.
8" INVERT
INFILTRATOR WATER TECHNOLOGIES
QUICK4 STANDARD CHAMBER
PRODUCT SPECIFICATIONS
(NOT TO SCALE)
QUICK4 STANDARD MULTIPORT
INSPECTION PORT END CAP
8"INVERT
"
171
-1
216
END L__34"�
VIEW
11.5" OUTLET END*
12" (EFFECTIVE LENGTH)
15" INLET END*
34" (EFFECTIVE LENGTH)
OWTS PROFILE SCHEMATIC
DOUBLE SWEEP
CLEANOUT
NOT TO SCALE
5.0' MIN
1 5.0' MAX
1 6" EXPOSED
r�
4" SCH. 40 PVC SOLID PIPE
FROM HOUSE TO TANK
HOUSE/GARAGE
FINISHED FLOOR
.,<.
ft
BLACK CANYON
I
p�p,00 LlcF
ti
H R�oF�sF4
55066 n
1) OWNER/BUILDER/CONTRACTOR TO VERIFY
ACCURACY OF SEPTIC (O.W.T.S) PLANS WITH
ARCHITECTURAL & OTHER PLANS AND NOTIFY
ENGINEER OF ANY DISCREPANCIES PRIOR TO
EXCAVATION, CONSTRUCTION OR MATERIALS
PURCHASE.
2) THE ENGINEER SHALL BE NOTIFIED A MINIMUM
OF 5 BUSINESS DAYS IN ADVANCE VIA EMAIL AT
INSPECTIONS@BLACKCANYON
ENGINEERS.COM FOR INSPECTION AS PER
NOTES ON PAGE SP2.
3) THE ENGINEER SHALL BE NOTIFIED IF ADVERSE
OR POOR SOIL CONDITIONS OR WATER ARE
ENCOUNTERED UPON EXCAVATION. FURTHER
ENGINEERING MAY BE REQUIRED
4) VALID, ORIGINAL DOCUMENT ONLY WITH
EMBOSSED, SIGNED SEAL
S) ALL NOTES & REQUIREMENTS FROM PAGE SP2
APPLY TO PAGE SPI
6) ALL MEASUREMENTS TAKEN WITH BASIC
COMPASS, RECREATIONAL LASER RANGE
FINDER & GPS. ACCURACY IS LIMITED TO THAT
OFFERED BY STATED INSTRUMENTS
7) STATED DIMENSIONS TAKE PRECEDENT OVER
MEASURED/SCALED DIMENSIONS
8) TOTAL PAGES: 2
SIZE: ANSI D ("22 X 34")
REV. DESCRIPTION DATE
Flmi Name and Address
Black Canyon Engineers
222 S Park Ave.
Montrose, CO 81401
970-568-5391
Support@BlackCanyonEngineers.com
www.BlackCanyonEngineers.com
Project Name and Address
Edinger OWTS
Parcel #239119400051
Carbondale, CO 81623
Garfield County, CO
Single Family Residence
Project Sheet
BCE122403
Date
02/11/25 S P 2
Scale
As Noted