NOTES:
NO WELL EXISTS ON THE PROPERTY. POTABLE WATER WILL BE HAULED IN
AND STORED IN A CISTERN LOCATED AT LEAST 100-FEET AWAY FROM THE
INSTALLED SOIL TREATMENT SYSTEM (AKA SEPTIC FIELD). THE WATERLINE
SHALL ALSO BE AT LEAST 25' AWAY FROM THE SOIL TREATMENT SYSTEM.
LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS
LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
10' MIN. FROM DRY GULCH
20' MIN.
FROM
FOUNDATION
6' MIN. TYP.
SOIL
T
R
E
A
T
M
E
N
T
A
R
E
A
(
S
T
A
)
90 QU
I
C
K
4
(
4
x
2
2
)
OR 72
A
D
S
A
R
C
3
6
(
4
x
1
8
)
IN A
T
R
E
N
C
H
C
O
N
F
I
G
U
R
A
T
I
O
N
(BOT
T
O
M
O
F
T
R
E
N
C
H
E
S
TO EA
C
H
B
E
L
E
V
E
L
)
APPROX. TEST PIT
LOCATION, TYP.
ACCESS ROAD
PROPOSED
1-BEDROOM
TINY HOME
(360 SF)
APPROX. TEST PIT
LOCATION, TYP.
INSTALL A TWO-WAY
CLEANOUT OUTSIDE
THE BUILDING
4"Ø SCH.40 PVC
SEWER, @ 2% MIN.
SLOPE, TYP.
INSTALL 1000-GALLON
TWO-COMPARTMENT SEPTIC
TANK WITH AN EFFLUENT
FILTER IN THE OUTLET RISER
OWTS DISTRIBUTION BOX
INSPECTION PORT
AT EACH END OF
EACH TRENCH, TYP.
50' SETBACK FROM THE
SOIL TREATMENT AREA
ABOVE GROUND
WATER CISTERN
37110DERIC J O N WA
L
T
E
R
COL O R A D O LICE
N
S
E
D
P
R
O
F
E
SSIONA L E N G INEER
6/1/26
00 60'120'
Scale: 1" = 60'
SURFACE
12"
8.
5
'
±
Villata Tiny Home
County of Garfield,
State of Colorado
Parcel No: 2127-272-00-285
Vicinity Map
SITE
ATTACH REMOVABLE CAP OR
THREADED CLEANOUT ASSEMBLY.
INSTALL MARKER IF CAP IS TO
BE BURIED.
FINISH GRADE
4"Ø PVC RISER
4"Ø PVC TWO-WAY
CLEANOUT TEE
4"Ø SEWER LINE
12" SQ. NYLOPLAST H-20
SOLID COVER ASSEMBLY
REMOVABLE PVC CAP
FLUSH WITH SURFACE
24"x24"x6" CONCRETE
IN LANDSCAPE
IN HARDSCAPE
To New Castle
Scale: N.T.S.
SITE & SOILS EVALUATION
Scale: N.T.S.
TWO-WAY CLEANOUT
2'
±
GENERAL ABSORPTION AREA NOTES
1.INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
2.ABSORPTION TRENCHES SHALL BE 3' WIDE OR LESS AND PARALLEL THE GROUND SURFACE CONTOURS.
PARALLELING TRENCHES SHALL BE SEPARATED BY A DISTANCE OF 6' MIN.
3.THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST
BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY
REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE.
4.DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT
SURFACE RUNOFF FROM ENTERING ABSORPTION AREA.
5.NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER
TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED.
6.UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST
OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR
GROUNDWATER IS ENCOUNTERED IN THE OVER-EXCAVATION.
7.TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING.
36" MAX.
6' (MIN.)
BOTTOM TO BE LEVEL AND FLAT OVER
ENTIRE AREA TO WITHIN 0.05'±. (TYP.)
REMOVE ANY ENCOUNTERED
BOULDERS AND BACKFILL WITH
LOAMY SAND OR SANDY GRAVELS. DO
NOT USE COMPACTED MATERIALS.
DO NOT WALK ON OR COMPACT
BOTTOM OF TRENCH.
FINISHED GROUND - MAINTAIN POSITIVE
SLOPE AWAY FROM TOP SURFACE OF
THE CHAMBER TRENCHES.
PVC COUPLING FOR SUPPORT
STANDARD INSPECTION PORT, TYP. (4"Ø
PVC SOLID PIPE CUT TO FIT. LOCATE PER
PLAN VIEW. ATTACH REMOVABLE CAP OR
THREADED CLEANOUT ASSEMBLY.
INFLOW PIPE SHALL ENTER
THE UPPER KNOCKOUTS
GRAVELLESS CHAMBER SYSTEM:
INFILTRATOR QUICK 4, ADVANCED
DRAINAGE SYSTEMS BIODIFFUSER
(STANDARD), OR ENGINEER
APPROVED EQUAL.
FILL
CIRCULAR IRRIGATION-STYLE VALVE
BOX & COVER - LID COLOR PURPLE
OR GREEN - LABEL "SEWER"
12" MIN
18" MAX
FILL
4"Ø PERFORATED PVC PIPE.
EXTEND PIPE TO REST ON
BOTTOM OF THE BED
Scale: N.T.S.
GRAVELESS CHAMBER ABSORPTION TRENCH
To Parachute
NORTH
923 Cooper Avenue, Ste. 201
Glenwood Springs, CO 81601
tele: 970.945.5252
www.bu-inc.com
Engineer or Surveyor Seal
Sheet
Client Information:
Project No.:
Filename:
Designer:
Drafter:
Date:
N:
\
P
R
O
J
E
C
T
S
\
2
0
2
6
\
2
6
0
2
1
-
V
i
l
l
a
l
t
a
O
W
T
S
\
d
w
g
\
2
6
0
2
1
-
V
-
T
o
p
o
.
d
w
g
6/
1
/
2
0
2
6
8
:
1
2
A
M
Subsurface Utility Engineering (SUE)
Required Project:
If "Yes", SUE Certification by:
Firm:
Job #:
Date:
Agency Approval
Agency:
Dept:
By:
Date:
Comments:
RevisionDate
----
----
----
----
6/1/26
RTC
DJW
26021-v-topo.dwg
26021
970.505-8694
SILT, CO 81652
1190 LINDA AVENUE
LEONIDAS VILLALTA
GA
R
F
I
E
L
D
C
O
U
N
T
Y
,
C
O
L
O
R
A
D
O
6/1/26 Rev. STA to 4 trenches, add pot. water cistern
--
-
-
On
s
i
t
e
W
a
s
t
e
w
a
t
e
r
T
r
e
a
t
m
e
n
t
S
y
s
t
e
m
(
O
W
T
S
)
Vi
l
l
a
l
t
a
T
i
n
y
H
o
m
e
O
W
T
S
C.1
NO
N/A
N/A
N/A
I-70
5.
5
'
±
4" PVC TEE/RISER
WITH EFFLUENT
FILTER ON THE
TANK OUTLET
4" PVC TEE/RISER
SILT
RIFLE
6"
6"
MAINTENANCE NOTES
1.TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL
CONSIDER THE FOLLOWING:
1.A.MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR
SYSTEM WILL WORK.
1.B.MINIMIZE SOLIDS GOING DOWN THE DRAIN.
1.C.ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A
MINIMUM.
1.D.MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN.
1.E.USE LINT FILTERS ON LAUNDRY MACHINE DRAINS.
1.F.KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN.
1.G.AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER.
1.H.DO NOT USE LYE-BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN-OFF,
OR OTHER STRONG CLEANING AGENTS.
1.I.DO NOT PUT ANY “ROOT DETERRENTS” DOWN THE DRAIN.
1.J.DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN
THE DRAIN
1.K.MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES.
2.THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK
ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED
AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE
PROPER FUNCTION OF THE SYSTEM.
NOTES:
THIS PLAN SET IS INTENDED TO BE PLOTTED IN
COLOR. FAILURE TO DO SO MAY RESULT IN MISSING
DATA & INFORMATION CRITICAL TO THE PROJECT.
SITE EVALUATION
1.SITE AND SOIL EVALUATIONS WERE PERFORMED BY:
DERIC J. WALTER, PE KEVIN DYE, PE
BOUNDARIES UNLIMITED INC.GEO QUEST
923 COOPER AVE., STE. 201 PO BOX 1372
GLENWOOD SPRINGS, CO 81601 RIFLE, COLORADO 81650
970.945.5252 970.318.6784
2.EVALUATION DATE(S): MAY 1, 2026.
3.3.SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER (GEO QUEST (PROJECT #26-141, MAY
1, 2026) AS USDA CLAY; TYPE 2A; WITH AN LTAR OF 0.10 GPD/SF.
4.SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER
OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=150 GPD:
4.A.SPRING, WELL OR POTABLE CISTERN=100'
4.B.POTABLE WATER SUPPLY LINE=25'
4.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=20'
4.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=10'
4.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10'
4.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25'
4.G.LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50'
4.H.DRY GULCH, CUT BANK OR FILL AREA=25'
4.I.SEPTIC TANK=5'
4.J.RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY
FEED)
3.SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1):
3.A.SPRING, WELL OR POTABLE CISTERN=50'
3.B.POTABLE WATER SUPPLY LINE=10'
3.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=5'
3.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=5'
3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10'
3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10'
3.G.LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50'
3.H.DRY GULCH, CUT BANK OR FILL AREA=10'
3.I.STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5'
FLOW
UNDISTURBED NATIVE SOILS
EX. GRA
D
E
5
%
±
1% MIN
3:1
M
A
X
G
R
A
D
E
3:1
M
A
X
G
R
A
D
E
1% MIN
SYSTEM DESIGN & CONSTRUCTION NOTES:
1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT
EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN
OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT
AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND
THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72-HOURS PRIOR TO THE DESIRED TIME OF BACKFILLING.
2.DEMAND CALCULATIONS (SEC.43.6.A.2.h)
2.A.ONE (1) BEDROOM TINY HOME <400 SF USING TREATMENT LEVEL 1 (TL1).
2.B.AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD5):
2.B.1.TINY HOME: 150 gpdc & 0.40 BOD5 lbs/day (PER TABLE 6-2)
2.B.2.ADWF:
2.B.2.1.TINY HOME = 150 gpd (MINIMUM PER TABLE 6-2)
2.B.2.2.ADWF = 150 gpd
2.B.3.BOD5 = 0.40 lbs/day
BOD5 mg/L = BOD5*1,000,000 = 0.4 lbs/day*1,000,000 = 320 mg/L
ADWF*8.34 150 gpd*8.34
2.B.4.CBOD5 = BOD5 * 0.85 = 272 mg/L
3.SEPTIC TANK (SEC.43.9.B.2.a):
3.A.INSTALL A 1,000 GALLON TWO-COMPARTMENT SEPTIC TANK WITH EFFLUENT FILTER IN THE OUTLET RISER. (TABLE 9-1)
3.B.THE TANK IS NOT SUBJECT TO BUOYANCY.
4.ABSORPTION AREA CALCULATIONS:
4.A.THE ABSORPTION AREA SLOPES ARE MODERATELY FROM NORTHWEST TO SOUTHEAST.
4.B.LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.10 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL).
4.C.MINIMUM SOIL TREATMENT AREA, A (PHASE 1):
A = ADWF = 150 = 1500 S.F.
LTAR 0.10 gpd/S.F.
4.D.SIZE ADJUSTMENT FACTORS: GRAVITY TRENCH = 1.0; CHAMBERS = 0.7 (TABLE 10-1A).
4.E.A,adj = 1500 SF * 1.0* 0.7 = 1050 SF
4.F.GRAVELLESS CHAMBER TRENCH SYSTEM:
4.F.1.INFILTRATOR QUICK4: 1050 SF / 12 SF/UNIT = 88 UNITS. INSTALL 88 UNITS IN FOUR (4) TRENCHES CONTAINING TWENTY-TWO (22) UNITS EACH.
4.F.2.ADS ARC 36: 1050 SF / 15 SF/UNIT = 70 UNITS. INSTALL 72 UNITS IN FOUR (4) TRENCHES CONTAINING EIGHTEEN (18) UNITS EACH.
5.THIS SYSTEM IS SIZED FOR TYPICAL HOUSEHOLD WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR
FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. BACKWASH AND FLUSHING FLOWS SHALL BE DISPOSED OF WITHIN A SEPARATE INFILTRATIVE SYSTEM.
6.CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS GREATER THAN 45° AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK.
7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION.
8.INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED.
9.INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO
CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET.
10.SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES
MEET THOSE REQUIRED.
TOPSOIL
CLAY, SAND, SILT,
BROWN, DRY
CLAY, SILT, SAND, GRAY,
CALCAREOUS, SOME
OXIDATION, DRY
EXCAVATE 6" DEEP. THE
SYSTEM MUST BE
INSTALLED AS SHALLOW AS
POSSIBLE TO UTILIZE THE
UPPER LEVEL SANDY CLAYS