Loading...
HomeMy WebLinkAboutRevised OWTS Design 06.03.2026> > > > > > > > > > > > > > > > > > > > > > > > > > > > C/O 5910 592 0 5890 5930 59 1 0 5 9 0 0 588 0 590 0 PR O P E R T Y L I N E ( S H O W N P E R C O U N T Y G I S . C O N T R A C T O R T O F I E L D V E R I F Y ) TP TP NOTES: NO WELL EXISTS ON THE PROPERTY. POTABLE WATER WILL BE HAULED IN AND STORED IN A CISTERN LOCATED AT LEAST 100-FEET AWAY FROM THE INSTALLED SOIL TREATMENT SYSTEM (AKA SEPTIC FIELD). THE WATERLINE SHALL ALSO BE AT LEAST 25' AWAY FROM THE SOIL TREATMENT SYSTEM. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 10' MIN. FROM DRY GULCH 20' MIN. FROM FOUNDATION 6' MIN. TYP. SOIL T R E A T M E N T A R E A ( S T A ) 90 QU I C K 4 ( 4 x 2 2 ) OR 72 A D S A R C 3 6 ( 4 x 1 8 ) IN A T R E N C H C O N F I G U R A T I O N (BOT T O M O F T R E N C H E S TO EA C H B E L E V E L ) APPROX. TEST PIT LOCATION, TYP. ACCESS ROAD PROPOSED 1-BEDROOM TINY HOME (360 SF) APPROX. TEST PIT LOCATION, TYP. INSTALL A TWO-WAY CLEANOUT OUTSIDE THE BUILDING 4"Ø SCH.40 PVC SEWER, @ 2% MIN. SLOPE, TYP. INSTALL 1000-GALLON TWO-COMPARTMENT SEPTIC TANK WITH AN EFFLUENT FILTER IN THE OUTLET RISER OWTS DISTRIBUTION BOX INSPECTION PORT AT EACH END OF EACH TRENCH, TYP. 50' SETBACK FROM THE SOIL TREATMENT AREA ABOVE GROUND WATER CISTERN 37110DERIC J O N WA L T E R COL O R A D O LICE N S E D P R O F E SSIONA L E N G INEER 6/1/26 00 60'120' Scale: 1" = 60' SURFACE 12" 8. 5 ' ± Villata Tiny Home County of Garfield, State of Colorado Parcel No: 2127-272-00-285 Vicinity Map SITE ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. FINISH GRADE 4"Ø PVC RISER 4"Ø PVC TWO-WAY CLEANOUT TEE 4"Ø SEWER LINE 12" SQ. NYLOPLAST H-20 SOLID COVER ASSEMBLY REMOVABLE PVC CAP FLUSH WITH SURFACE 24"x24"x6" CONCRETE IN LANDSCAPE IN HARDSCAPE To New Castle Scale: N.T.S. SITE & SOILS EVALUATION Scale: N.T.S. TWO-WAY CLEANOUT 2' ± GENERAL ABSORPTION AREA NOTES 1.INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2.ABSORPTION TRENCHES SHALL BE 3' WIDE OR LESS AND PARALLEL THE GROUND SURFACE CONTOURS. PARALLELING TRENCHES SHALL BE SEPARATED BY A DISTANCE OF 6' MIN. 3.THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4.DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5.NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6.UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE OVER-EXCAVATION. 7.TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. 36" MAX. 6' (MIN.) BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.05'±. (TYP.) REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. DO NOT WALK ON OR COMPACT BOTTOM OF TRENCH. FINISHED GROUND - MAINTAIN POSITIVE SLOPE AWAY FROM TOP SURFACE OF THE CHAMBER TRENCHES. PVC COUPLING FOR SUPPORT STANDARD INSPECTION PORT, TYP. (4"Ø PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INFLOW PIPE SHALL ENTER THE UPPER KNOCKOUTS GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL. FILL CIRCULAR IRRIGATION-STYLE VALVE BOX & COVER - LID COLOR PURPLE OR GREEN - LABEL "SEWER" 12" MIN 18" MAX FILL 4"Ø PERFORATED PVC PIPE. EXTEND PIPE TO REST ON BOTTOM OF THE BED Scale: N.T.S. GRAVELESS CHAMBER ABSORPTION TRENCH To Parachute NORTH 923 Cooper Avenue, Ste. 201 Glenwood Springs, CO 81601 tele: 970.945.5252 www.bu-inc.com Engineer or Surveyor Seal Sheet Client Information: Project No.: Filename: Designer: Drafter: Date: N: \ P R O J E C T S \ 2 0 2 6 \ 2 6 0 2 1 - V i l l a l t a O W T S \ d w g \ 2 6 0 2 1 - V - T o p o . d w g 6/ 1 / 2 0 2 6 8 : 1 2 A M Subsurface Utility Engineering (SUE) Required Project: If "Yes", SUE Certification by: Firm: Job #: Date: Agency Approval Agency: Dept: By: Date: Comments: RevisionDate ---- ---- ---- ---- 6/1/26 RTC DJW 26021-v-topo.dwg 26021 970.505-8694 SILT, CO 81652 1190 LINDA AVENUE LEONIDAS VILLALTA GA R F I E L D C O U N T Y , C O L O R A D O 6/1/26 Rev. STA to 4 trenches, add pot. water cistern -- - - On s i t e W a s t e w a t e r T r e a t m e n t S y s t e m ( O W T S ) Vi l l a l t a T i n y H o m e O W T S C.1 NO N/A N/A N/A I-70 5. 5 ' ± 4" PVC TEE/RISER WITH EFFLUENT FILTER ON THE TANK OUTLET 4" PVC TEE/RISER SILT RIFLE 6" 6" MAINTENANCE NOTES 1.TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: 1.A.MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B.MINIMIZE SOLIDS GOING DOWN THE DRAIN. 1.C.ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D.MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E.USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F.KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G.AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H.DO NOT USE LYE-BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN-OFF, OR OTHER STRONG CLEANING AGENTS. 1.I.DO NOT PUT ANY “ROOT DETERRENTS” DOWN THE DRAIN. 1.J.DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN 1.K.MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2.THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. NOTES: THIS PLAN SET IS INTENDED TO BE PLOTTED IN COLOR. FAILURE TO DO SO MAY RESULT IN MISSING DATA & INFORMATION CRITICAL TO THE PROJECT. SITE EVALUATION 1.SITE AND SOIL EVALUATIONS WERE PERFORMED BY: DERIC J. WALTER, PE KEVIN DYE, PE BOUNDARIES UNLIMITED INC.GEO QUEST 923 COOPER AVE., STE. 201 PO BOX 1372 GLENWOOD SPRINGS, CO 81601 RIFLE, COLORADO 81650 970.945.5252 970.318.6784 2.EVALUATION DATE(S): MAY 1, 2026. 3.3.SOIL WAS CLASSIFIED BY THE GEOTECHNICAL ENGINEER (GEO QUEST (PROJECT #26-141, MAY 1, 2026) AS USDA CLAY; TYPE 2A; WITH AN LTAR OF 0.10 GPD/SF. 4.SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=150 GPD: 4.A.SPRING, WELL OR POTABLE CISTERN=100' 4.B.POTABLE WATER SUPPLY LINE=25' 4.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=20' 4.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=10' 4.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 4.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 4.G.LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 4.H.DRY GULCH, CUT BANK OR FILL AREA=25' 4.I.SEPTIC TANK=5' 4.J.RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3.SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A.SPRING, WELL OR POTABLE CISTERN=50' 3.B.POTABLE WATER SUPPLY LINE=10' 3.C.STRUCTURE W/ BASEMENT/CRAWL SPACE=5' 3.D.STRUCTURE W/O BASEMENT/CRAWL SPACE=5' 3.E.PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F.INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G.LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H.DRY GULCH, CUT BANK OR FILL AREA=10' 3.I.STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' FLOW UNDISTURBED NATIVE SOILS EX. GRA D E 5 % ± 1% MIN 3:1 M A X G R A D E 3:1 M A X G R A D E 1% MIN SYSTEM DESIGN & CONSTRUCTION NOTES: 1.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER AND THE COUNTY ENVIRONMENTAL HEALTH OFFICER MUST BE MADE AT LEAST 72-HOURS PRIOR TO THE DESIRED TIME OF BACKFILLING. 2.DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A.ONE (1) BEDROOM TINY HOME <400 SF USING TREATMENT LEVEL 1 (TL1). 2.B.AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD5): 2.B.1.TINY HOME: 150 gpdc & 0.40 BOD5 lbs/day (PER TABLE 6-2) 2.B.2.ADWF: 2.B.2.1.TINY HOME = 150 gpd (MINIMUM PER TABLE 6-2) 2.B.2.2.ADWF = 150 gpd 2.B.3.BOD5 = 0.40 lbs/day BOD5 mg/L = BOD5*1,000,000 = 0.4 lbs/day*1,000,000 = 320 mg/L ADWF*8.34 150 gpd*8.34 2.B.4.CBOD5 = BOD5 * 0.85 = 272 mg/L 3.SEPTIC TANK (SEC.43.9.B.2.a): 3.A.INSTALL A 1,000 GALLON TWO-COMPARTMENT SEPTIC TANK WITH EFFLUENT FILTER IN THE OUTLET RISER. (TABLE 9-1) 3.B.THE TANK IS NOT SUBJECT TO BUOYANCY. 4.ABSORPTION AREA CALCULATIONS: 4.A.THE ABSORPTION AREA SLOPES ARE MODERATELY FROM NORTHWEST TO SOUTHEAST. 4.B.LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.10 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.C.MINIMUM SOIL TREATMENT AREA, A (PHASE 1): A = ADWF = 150 = 1500 S.F. LTAR 0.10 gpd/S.F. 4.D.SIZE ADJUSTMENT FACTORS: GRAVITY TRENCH = 1.0; CHAMBERS = 0.7 (TABLE 10-1A). 4.E.A,adj = 1500 SF * 1.0* 0.7 = 1050 SF 4.F.GRAVELLESS CHAMBER TRENCH SYSTEM: 4.F.1.INFILTRATOR QUICK4: 1050 SF / 12 SF/UNIT = 88 UNITS. INSTALL 88 UNITS IN FOUR (4) TRENCHES CONTAINING TWENTY-TWO (22) UNITS EACH. 4.F.2.ADS ARC 36: 1050 SF / 15 SF/UNIT = 70 UNITS. INSTALL 72 UNITS IN FOUR (4) TRENCHES CONTAINING EIGHTEEN (18) UNITS EACH. 5.THIS SYSTEM IS SIZED FOR TYPICAL HOUSEHOLD WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. BACKWASH AND FLUSHING FLOWS SHALL BE DISPOSED OF WITHIN A SEPARATE INFILTRATIVE SYSTEM. 6.CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS GREATER THAN 45° AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8.INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9.INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10.SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. TOPSOIL CLAY, SAND, SILT, BROWN, DRY CLAY, SILT, SAND, GRAY, CALCAREOUS, SOME OXIDATION, DRY EXCAVATE 6" DEEP. THE SYSTEM MUST BE INSTALLED AS SHALLOW AS POSSIBLE TO UTILIZE THE UPPER LEVEL SANDY CLAYS