HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLCO-05-26-9859
POWERS ART CENTER
PERMIT FOR AN ARTS PAVILION, OPEN AIR, NO HEAT
13110 HIGHWAY 82, CARBONDALE
1) THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS.
2) THE SINK IS NOT ALLOWED WITHOUT POTABLE WATER AND THE DRAIN
CONNECTED TO A PERMITTED OWTS (SEPTIC) SYSTEM. REDLINED ON THE PLANS.
3) A 3'0" X 6'8" SWINGING DOOR IS REQUIRED FOR EGRESS. PLEASE HAVE THE DOOR
IN PLACE BY FRAMING INSPECTION.
4) A PERMANENT SIGN IS TO BE POSTED BY THE EXIT DOOR STATING THE MAXIMUM
OCCUPANT LOAD IS 49 OCCUPANTS.
5) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS.
6) A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
HTTPS://WWW.COLORADO.GOV/PACIFIC/DORA/DPO ELECTRICAL PLUMBING PE
RMITS
7) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE.
8) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
9) PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING
DEPARTMENT, WELDING AND BOLTING IS MINIMUM.
10) GEOTECHNICAL OBSERVATION IS REQUIRED WHEN THE EXCAVATION IS
COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION,
2000 PSF.
11)ALL EXTERIOR LIGHTING IS TO BE DOWNCASTAND SHIELDED.
12) SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE
CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4)
13) UFER GROUNDS ARE REQUIRED TO BE INSPECTED AT FOOTING INSPECTION
14) INSTALL STORMWATER CONTROLS PRIOR TO ANY DIRT WORK.
15)CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING
PLANTS AND SEEDS.
16) PROVIDE EROSION CONTROLS UNTIL SEEDED AREAS CAN BE ESTABLISHED.
17) PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION.
18) FOLLOW ENGINEERED PLANS. VERIFY ANY CHANGES WITH THE ENGINEER.