HomeMy WebLinkAboutSite Plank-------------------
1
I
i
NOTE:
LOCATION OF PRIVATE ISDS
(SEPTIC SYTEM) INDICATED IS
APPROXIMATE, VERIFY EXACT
LOCATION IN THE FIELD
Lot 27
NOTE:
LOCATION OF UNDERGROUND
UTILITY LINES INDICATED ARE
APPROXIMATE, VERIFY EXACT
LOCATION IN THE FIELD
NOTE:
COORDINATE CROSSING OF
NEW UNDERGROUND
NATURAL GAS SERVICE LINE
AND OTHER BURIED UTILITY
LINES. I
PROVIDE "HOT TAP" AT NEW
SERVICE. LINE TO EXISTING
BURIED UTILITY COMPANY I
NATURAL GAS LINE RUNNING
PARALLEL TO THE STREET.
QO Q
JG
4
ry
5/8" Rebar & �,0
Aluminum Cap
LS No. 13501 q
F
Site Benchmark
Elevatlon=5456M'
528" 3"E 332.21
10'-0"'
(3.17
N ( FUTURE Entry Fir:
OVERED
m RRACE T. PIY•
5462.5
• v" BURIED -1.
SEPTIC
•... -
— ;TANK
_____ _____ _-------------
1 e� -
s
-
I
Garage '
T. Slab _ f L
I MOTORCOURT 5461.33 _
' I 1 DETACH D
5'-2„ GARAG
/-24'x33 -6
I � 1
I i i I
LANDSCAPE
' ISLAND
CO
1 , .
1 I ,
I I I
I
121-01,
pos ob'�° w i DRIVEWAY
I
of Qab� ti 4 ��a iy Syr
I 1
'-----`------ ,� 1`040
addl
50,
m
NOTE:
MOTORCOURT AND
DRIVEWAY ARE
ASPHALT PAVING
t 26
II± as platted)
9
aU
b
C7
4�
Z y �S,hyo
� o
y\
OVERALL SITE PLAN
1"= 30'-0"
SITE NOTES:
1. ADDRESS NUMBERS
BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING
NUMBERS OR APPROVED BUILDING IDENTIFICATION (4" HIGH MINIMUM)
PLACED IN A POSITION THAT IS PLAINLY LEGIBLE AND VISIBLE FROM THE
STREET OR ROAD FRONTING THE PROPERTY (R319.1)
2. UTILITIES
ALL BUILDING UTILITY LINE CONNECTIONS, LOCATIONS AND ROUTING
SHALL BE VERIFIED IN THE FIELD AND SHALL BE LOCATED UNDERGROUND.
3. AIR CONDITIONING OR COOLING UNITS:
NO AIR CONDITIONING OR EVAPORATIVE COOLING UNITS IF INSTALLED, ON
THE VERTICAL WALL OF A RESIDENCE OR ON THE YARD OF ANY LOT, IT
SHALL BE APPROPRIATELY SCREENED FROM VIEW OF THE STREET, THE
METHOD OF SCREENING TO BE APPROVED BY THE ASSOCIATION OR THE
ARCHITECTURAL CONTROL COMMITTEE.
NOTE:
1. THE OWNER AND GENERAL CONTRACTOR ARE RESPONSIBLE FOR ESTABLISHING A
PROJECT TOPOGRAPHIC BENCHMARK ELEVATION IN THE FIELD.
2. THE OWNER AND GENERAL CONTRACTOR SHALL VERIFY THE T. PLY. 100'-0 SITE
ELEVATION EQUIVALENT IN THE FIELD.
3. DO NOT REVISE THE SITE ELEVATION EQUIVALENT T. PLY. 100'-0 UNTIL PALOMINO
RESIDENTIAL DESIGN IS NOTIFIED.
AC CONDENSOR -
APPROXIMATE LOCATION, PROVIDE ADEQUATE SERVICE CLEARANCE TO PROPERY
LINE AND SCREENING TO MEET CONDENSOR MANUFACTURER AND HOA ESTHETIC
REQUIREMENTS
.,r
//�•
F-�
it
4r
�
I
b
o
c
�I
U
A
C7
�a
dim
z
Boa
O gti
O a 9 '✓
a S e
a 3
W �
g Leg L�Sg
-2Eg
glgfi
�E
8'P S"Stt�e
9 Sg E
� I
d
w
A
Rev 10 `� a
�w
Not For °
m O M
T
% b
Construction T�
5-19-26
NOTE:
SITE INFORMATION BASED ON SURVEY DATED 4-13-26
PREPARED BY THE SEXTON SURVEYING COMPANY, A161 �
PROJECT N0. 26031
BUILDING FLOOR ELEVATION
BUILDING ELEVATION 100'-0- = SITE ELEVATION xmC VIF
1 26-0326 A1.1