HomeMy WebLinkAboutCorrespondence-Fire MarshalJohn Piano From: Orrin Moon <Orrin.Moon@Crfr.us> Sent: Tuesday, August 27, 2024 5:33 PM To: John Plano Subject: Re: Harvey Gap Road John, After reviewing the grading permit for Parcel D Grand Hogback Subdivision assessor's Parcel Number 212724100385, grading permit application, I have the following requirements as far as emergency access to the future 23 lots. 1. The plans show 2737of roadway that is only 11' wide road that show's to be covered with 4" of gravel. This roadway does not even enter the last three lots on the plat. This road will not support the weight of apparatus or allow emergency apparatus to pass another vehicle on any part of the road. Chapter 5 of the 2015 International Fire Code section 503.1.1 , " approved fire apparatus access roads shall be provided for everyfacility, building or portion of a building hereafter constructed or moved into or within the jurisdiction. The fire apparatus access road shall comply with the requirements of this section and shall extend to within 150' of all portions of the facility". Section 503.2 says "Fire apparatus access roads shall be installed and arranged in accordance with section 503.2.1 through 503.2.8". 1 will require 20' of roadway excluding shoulders that will have all weather driving surface designed and maintained to support the imposed loads of fire apparatus. The roads design shall be engineered to support the road and signed off by a Civil Engineer. The road design shall be extended through lot 21-a and Lot 22 to allow for the road to access lot 23. An approved fire apparatus turnaround is required at the end of the road in lot 22 or 23. Road will be signed " No Parking on Roadway" signage separation on roadway will be approved by my office. 2. Lot residential homes or buildings shall be designed for fire apparatus access roads at time of building permit application and approved by this office. 3. Water supply designed for this subdivision shall be in place and storage tank shall be accessible by fire apparatus before any building permits will be issued. Please feel free to contact me with any questions or concerns on this project. Orrin E. Moon, Division Chief/Fire Marshal Colorado River Fire Rescue. From: John Plano <jplano@garfield-county.com> Sent: Thursday, August 22, 2024 4:40 PM To: Orrin Moon <Orrin.Moon@Crfr.us> Subject: Harvey Gap Road Orrin, 1 We got the Grading Permit in for the road they built to subdivide the 291 acres in the future. It's 12' wide with no turn outs and not much of a turnaround area at the end. If you would give me your comments, IT send a correction letter to the applicant. John Plano Chief Building Official Garfield County Building Department 108 8th Street #401 Glenwood Springs, CO 81601 (970) 945-1377 Ext. 1560 John Piano From: Orrin Moon <Orrin.Moon@Crfr.us> Sent: Monday, June 8, 2026 4:26 PM To: John Plano; chris@mountaincross-eng.com; Steve Smith Subject: Re: Grading Permit for GarCo Parcel # 2127 241 00385 (Tract E), Jarvey Gap Road: Grad -8860 John, The new plans have addressed my concerns for this project, and I am good even with the wording on lot purchaser's driveway requirements. As far as my concern you can issue them a permit. Thank You, Orrin D. Moon Prevention Division Chief/Fire Marshal Colorado River Fire Rescue 970-625-1243 orrin.moon@crrfr.� From: John Plano <jplano@garfieldcountyco.gov> Sent: Monday, June 8, 2026 12:17 PM To: chris@mountaincross-eng.com <chris@mountaincross-eng.com>; Orrin Moon <Orrin.Moon @Crfr.us> Subject: FW: Grading Permit for GarCo Parcel # 2127 24100385 (Tract E), Jarvey Gap Road: Grad -8860 Guys, Here is the response to the most recent comments. Please let me know if it's hitting the mark... Thanks for your input, John Plano Chief Building Official Garfield County Building Department 108 8th Street #401 Glenwood Springs, CO 81601 (970) 945-1377 Ext. 1560 From: Steve Smith <SSmith@bu-inc.com> Sent: Friday, June 5, 2026 3:32 PM To: John Plano <jplano@garfieldcountyco.gov> Subject: Grading Permit for GarCo Parcel # 2127 24100385 (Tract E), Jarvey Gap Road: Grad -8860 Please find resubmittal addressing your January comments. We had a most productive meeting with Fire Chief Moon and have addressed all his issues. Attached are: 3 page Construction Plans Revised Cost Estimate Revised Easement Document Exhibit A with Hammerhead description Copy of Book that will be on -site with Construction Stormwater General Permit Ownership group is applying/obtaining COR 400000, getting Fire Cistern Covenants, Road Group Declaration and Road Maintenance Agreements executed (I assume the revised Easement Document Exhibit A will be part of). Do the CR 237 addresses get assigned at building permit or can I get them prior? Thank you...... Steven L. Smith