Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLCO-06-26-9951-KITCHEN BLCO-06-26-9950 -LEARNING LAB AVLT - COFFMAN RANCH TWO PERMITS ARE COVERED WITHIN THE PLANS 1837 COUNTY ROAD 100 CARBONDALE, PARCEL: 239336321001 1) PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY ON THE LEARNING LAB AND THE KIT(--I-IEnI BUILDINGS, THE APPLICANT SHALL PROVIDE THE NEW \niEi I_ PERMIT AND WELL WATER QUALITY TEST REPORTS AND PUMP TEST. PRIOR TO THE ISSUANCE OF THE CO'S THE CURRENT AGRITOURISM OPERATIONS MAY CONTINUE AS ALLOWED UNDER THE LUDC. 2) GEOTECHNICAL OBSERVATION IS REQUIRED WHEN THE EXCAVATION IS COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION, 3000 PSF. 3) IT APPEARS THE SITE PLAN/CIVILS HAVE CHANGED SINCE THE POLE BARN WAS ISSUED. THE ACCESSIBLE ROUTE TO THE POLE BARN IS NOT SHOWN IN THESE DRAWINGS. BASED ON THE NEW DESIGN, AN ACCESSIBLE ROUTE FROM THE LEARNING CENTER TO THE TO THE KITCHEN AND BARN IS REQUIRED. I'M NOT THE DESIGNER BUT I WOULD SUGGEST THE 6" STEP OFF THE DECK BE A SMALL RAMP. IBC 1012.8 AND ANSI A117.1 405.8 WAIVES HANDRAIL FOR RAMPS 6" OR LESS. BUT EDGE PROTECTION IS STILL REQUIRED. 405.9. 4) IF ANY OF THE DECK IS OVER 30" ABOVE GRADE, A 42" TALL GUARDRAIL WILL BE REQUIRED. 5) ALL nECK FRAMING IS TO BE NATURALLY DURABLE WOOD OR PRESSURE TREATED FOR AGAINST DECAY. (IBC 2304.12.2.3) 6) EMERGENCY LIGHTS AND EXIT SIGNS ARE REQUIRED IN THE LEARNING LAB. 7) THE WALLS SURROUNDING THE TOILET ARE TO BE NON -ABSORBENT FOR A HEIGHT OF 48" AND 2' PAST ON EACH SIDE OF THE TOILET. 8) DOOR HARDWARE IS NOT SPECIFIED. ALL ACCESSIBLE DQQR PAPM TARE gHALL HAVE A SHAPE THAT IS EASY TO GRIP, INCLUDING POCKET AND SLIDING DOORS. (ANSI Al 17.1 - 404.2.6) 9) THE ACCESSIBLE PARKING SPACES SHALL HAVE SI(---J^JAG-. 10)THE ACCESSIBLE STALL DOORS ARE TO MAINTAIN 32" !N THE CLEAR. THE DRAWINGS ARE SPECIFYING 2'6" DOORS, WHICH DOES NOT COMPLY. 11)THE 3 COMPARTMENT SINK WASTE LINE IS TO HAVE A GREASE TRAP AND AN AIR GAP. m 12)THE APPROVED PLANS ARE TO BE ON -SITE FOR INSPECTIONS. 13) SANITARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS. 14)A LIST OF REQUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. HTTPS•//WWW COLORADO GOV/PACIFIC/DORA/DPO ELECTRICAL PLUMBING PE RM ITS 15) UNDERGROUND UTILITY LOCATES IS THE RESPONSIBILITY OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE. 16) DRAINAGE ACROSS PROPERTY LINES SHALL NOT EXCEED THAT WHICH EXISTED PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILITY. EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY INSTALLATION OF NON -EROSIVE DOWN DRAINS OR OTHER DEVICES. 17)ANY RETAINING WALL OVER 48" TALL REQUIRES TO BE DESIGNED BY A STRUCTURAL OR CIVIL ENGINEER DEPENDING ON THE TYPE OF MATERAIL USED. THE 48" HEIGHT IS MEASURED FROM THE BOTTOM OF THE FOOTING THAT IS BELOW GRADE, NOT THE FACE OF THE WALL. 18) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 19) INTERIOR SLABS ARE REQUIRED TO HAVE A 6 MIL VAPOR BARRIER. 20)ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED. 21) SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL BE CHECKED DURING THE FRAMING AND FINAL INSPECTION. (IBC 2406.4) 22)A PASSING BLOWER DOOR TEST IS REQUIRED TO BE SUBMITTED PRIOR TO ISSUING THE CERTIFICATE OF OCCUPANCY. 23) UFER GROUNDS ARE REQUIRED TO BE INSPECTED AT FOOTING INSPECTION 24)ANY EXPOSED FOAM IS TO BE COVERED WITH AN IGNITION BARRIER OR A THERMAL BARRIER BASED ON LOCATION. (IRC R316) 25) INSTALL STORMWATER CONTROLS PRIOR TO ANY DIRT WORK. 26) CONTROL NOXIOUS WEEDS. TREAT EXISTING WEEDS PRIOR TO RELOCATING PLANTS AND SEEDS. 27) PROVIDE EROSION CONTROLS UNTIL SEEDED AREAS CAN BE ESTABLISHED. 28) PROVIDE DUST CONTROL AS REQUIRED DURING CONSTRUCTION. 29) KITCHEN HOODS OVER 400 CFM REQUIRE MAKE-UP AIR. THE STOVE MANUFACTURER DICTATES THE REQUIRED CFM'S REQUIRED. 30) SEPARATE SIGN PERMITS ARE REQUIRED FOR ANY EXTERNAL SIGNS. PLEASE CONTACT THE COUNTY PLANNER FOR THE APPLICATION. 31)A KNOX BOX MAY BE REQUIRED, IT IS TO BE MOUNTED ADJACENT TO THE FRONT DOOR. PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR NEED AND EXACT LOCATION. 32) GRAB BAR BACKING IS TO BE IN PLACE FOR ALL ACCESSIBLE TOILETS.