HomeMy WebLinkAboutIndoor & Outdoor Unit SpecsJob Name: Coffman Ranch System Reference: Learning Lab Vertical (Indoor) Air Handling Unit INDOOR UNIT FEATURES Date: Exterior Heat Pump Mounted on 12" stand AGL 7/29/2026 INDOOR Unit ... SVZ-AP60NL OUTDOOR Unit ... SUZ-AK60NL Hyper Heat not avaible for this Heat Pump • Three Speed Fan: Adjust the fan between three speed settings to optimal comfort. • Auto Changeover: The unit will automatically switch between heating and cooling modes to maintain your desired temperature. • Multi -Position Installation: Versatile installation options, including horizontal (left or right) and vertical (up or down) orientations, with included drain pans to facilitate easy setup for any configuration. • Blow Through Design: A unique blow -through design allows for easier cleaning and maintenance of the cabinet. OUTDOOR UNIT FEATURES • Inverter Driven Compressor: Inverter technology uses only the precise amount of energy needed to keep a space comfortable - • Blue Fin Coating: Anti -corrosion coating that protects the outdoor heat exchanger against salt, sulfur, and other airborne contaminants that impact the efficiency and performance of the outdoor units. • Seacoast Protection: Designed to protect against the corrosive effects of environments that are in close proximity to the sea. Cooling at 95F1 Maximum Capacity Btu/h 60000 Rated Capacity Btu/h 60000 Minimum Capacity Btu/h 18500 Maximum Power Input W 6070 Rated Power Input W 5490 Moisture Removal Pints/h 14.30 Sensible Heat Factor 0.74 Power Factor [208V / 230V] / 99 / 99 Heating at 47F z Maximum Capacity Btu/h 66500 Rated Capacity Btu/h 64500 Minimum Capacity Bluth 14600 Maximum Power Input W 6590 Rated Power Input W 6390 Power Factor [208V / 230V] / 97 / 97 Heating at 17F3 Maximum Capacity Btu/h 42500 Rated Capacity Btu/h 42500 Maximum Power Input W 5415 Rated Power Input W 5415 Heating at 5F5 Maximum Capacity Btu/h 34600 Maximum Power Input W 5070 Heating at -4F6 Maximum Capacity Btu/h 31000 Efficiency SEER2 17 EER21 9 HSPF2 [IV] 8 COP at 47°F2 29 COP at 17°F at Maximum Capacity3 2.30 COP at 5'F at Maximum Capacity5 2 COP at -4°F at Maximum Capacity6 1.88 ENERGY STAR® Certified No Electrical Voltage, Phase, Frequency V AC / V AC . Hz 208 / 230 .1 60 Guaranteed Voltage Range VAC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC IDU Powered Separately Voltage: Indoor - Outdoor, S2-S3 V DC 12-24 Short-circuit Current Rating SCCR] kA 5 Recommended Fuse/Breaker Size (Outdoor) A 40 Recommended Wire Size[Indoor-Outdoor] AWG 14 Indoor Unit MCA A 9.3 MOCP A 15 Fan Motor Output W 750 Fan Motor Type DC Motor Airflow Rate at Cooling, Dry CFM 1155 , 1400 , 1650 Airflow Rate at Heating, Dry CFM 1225 .1465 , 1750 Sound Pressure Level [Cooling] dB (A) Sound Pressure Level [Heating]dB (A) 48 , 55 , 56 External Static Pressure in.WG 0.30. 0.50. 0.80 Drain Pipe Size O.D. inch [ mm J 314 [19.05 ] External Finish Color 6.2PB 9/0.9 Unit Dimensions W x D x H ( ) inch x inch x inch [ mmxmmxmm] 25 x 21-5/8 x 59-1/2 [ 635 x 548 x 1511] Package Dimensions (W x D x H) inch x inch x inch [ mmxmmxmm) 26 x 28-314 x 66 [ 660 x 730 x 1675 ] Unit Weight Ibs [ kg ] 176 [ 60 ] Package Weight Ibs [ kg ] 200 [ 911 IDU Operating Temp. Range Cooling Intake Air Temp [Maximum / Minimum] deg F, deg F / deg F , deg F 90, 73 / 66 , 59 Heating Intake Air Temp [Maximum / Minimum] deg F 82 / 50 Outdoor Unit MCA A 38 MOCP A 87 Notes 'Cooling (Indoor // Outdoor) °F 80 DB, 67 W8 H 95 DB, 75 WB 21-leating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 31-leating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB SHeating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB -Indoor/Ouldoor Unit Operating TemliperaWre Range (Cooling Air Temp [Maximum / Minimum]): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient Oempereture conditions. 'Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode and automatically restarts at these temperatures. 61-lealing at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB Use 1/4 liquid line for SUZ-AA24/30/36NL, adapter is included with the outdoor unit Outdoor Unit Fan Motor Output W 213+213 Airflow Rate Cooling CFM 4020 Airflow Rate Heating CFM 4020 Defrost Method Reverse Cycle Coating on Heat Exchanger (Bluefin, Sea Coast) Yes, Yes Sound Pressure Level, Cooling' dB (A) 60 Sound Pressure Level, Healingz dB (A) 62 Compressor Type Twin Rotary Compressor Model MRK53FFJMC-L Compressor Oil [Type // Charge] // oz RM68EH // 60 External Finish Color Munsell 3Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions (W x D x H) inch x inch x inch [ mmxmmxmm] 41-11132 x 14 x 52-43/64 [ 1050 x 355 x 1338 ] Package Dimensions (W x D x H) inch x inch x inch [ mmxmmxmm] 42-15/16 x 17-3/4 x 58-5/16 [ 1090 x 450 x 1480 ] Unit Weight Ibs [ kg ] 265 [ 120 ] Package Weight Ibs [ kg ] 291 [132 ] ODU Operating Temp Range Cooling Intake Air Temp [Maximum / Minimum"] F 115123 Heating Intake Air Temp [Maximum / Minimum] F, F / F, F 70, 59 /-4 , -4 Heating Thermal Lock -out / Re -start Temperatures" F -13 /-4 Refrigerant Type R454B Pre -Charged Refrigerant Amount Ibs , oz 11 , 7 Maximum Pre -Charged Piping Length ft [ m ] 100 [ 30 ] Additional Refrigerant Charge Per Additional Piping Length oz/ft 0.60 Piping - Gas Pipe Size O.D. [Flared] inch [ mm ] 3/4 [ 19.05 ] Liquid Pipe Size O.D. [Flared] inch [ mm ] 3/8 [ 9.521 Maximum Piping Length ft [ m ] 245 [ 75 ] Maximum Height Difference It [ m ] 100 [ 30 ] Maximum Number of Bends 15 Notes 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB zHeating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB //47 DB, 43 WB 31-leating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 5Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): - Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. 'Outdoor Unit Operating Temperature Range (Coaling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode and automatically restarts at these temperatures. sHealing at -4°F (Indoor // Outdoor) °F 70 DB, 60 WB //-4 DB, -5 WB Use 114liquid line for SUZ-AA24/30/36NL, adapter is included with the outdoor unit Sauermann Condensate Pump 120-230V up to 60k BTU/h IJ 5130-230 Condensate Refco Condensate Pump 100-240V up to 120k BTU/h El COMBI Blue Diamond Advanced Mini Condensate Pump w Reservoir Sensor 208230V recommended X88-721 Blue Diamond MegaBlue Condensate Pump with Reservoir Sensor 115-230V up to 170k BTU/h X87-835 Blue Diamond Sensor Extension Cable 15 Ft C13-103 kumo station@ for Comfort app � PAC-WHS01 HC-E Airzone Wired Blueface Controller White AZZBSBLUEZEROCB Procon BACnett7 and Modbus® Interface ❑ PAC-UKPRC001-CN-1 Control Interface Airzone Wireless Think Controller White ❑ AZZBSTHINKRB Operation and Error Status Output Adapter PAC-SF40RM-E Wireless Interface 2 for Comfrot app O PAC-USWHS002-WF-2 IT Extender PAC-WHS011E-E Airzone Wireless Think Controller Black 11 AZZBSTHINKRN Thermostat Interface for 3rd Party Thermostats PAC-US445CN-1 Airzone Wireless Lite Controller While AZZBSLITERB Airzone Wired Lite Controller White AZZBSLITECB Airzone Wired Blueface Controller Black AZZSSBLUEZEROCN Control Wire 202PR 1 PR shielded 1 PR plenum wire for Airzone 100 ft reel CW2042S2-100 202PR shielded 1 PR plenum wire for Airzone 500 ft reel CW2042S2-500 Disconnect Switch 30A600VUL fits 2 X 4 utility box - Black TAZ-MS303 (30A/600WUL) [fits 2" X 4" utility box) - White TAZ-MS303W Downflow Kit Condensate Management Kit for downflow installation Ej CMA-1 Electric Heat Lockout Electric Heat Lockout ETC-211020-MIT Electric Kit Heats 15kW Electric Heater Module - Large Cabinet EH15-MPAS-LB 19kW Electric Heater Module - Large Cabinet EH19-MPAS-LB 10kW Electric Heater Module - Large Cabinet EH10-MPA-LB 17.5kW Electric Heater Module - Large Cabinet IJ EH17-MPAS-LB Lineset 50 x 3/8 x 50 x 3/4 Lineset Twin -Tube Insulation MPLS383412T-50 15 x 3/8 x 15 x 3/4 Lineset Twin -Tube Insulation MPLS383412T-15 Power Supplies & Auxiliary Components ERV On/Off Input Adapter for CNER on SVZ PEAD and PVA models PAC-740 Remote Sensor Flush Mount Remote Temperature Sensor for SEZ SLZ SVZ and all P-Series models PAC-USSEN002-FM-1 Wireless temperature and humidity sensor for Comfort app PAC-USWHS003-TH-1 Wall Mounted Remote Temperature Sensor PAC-SE41TS-E Terminal Block Separate Terminal Power Block SPTB1 Terminal Signal Adapter 3-Pin Wiring Harness PAC-715AD 5-Pin Wiring Harness PAC-725AD Backup Heat Relay Kit CN24RELAY-KIT-CM3 Touch MA Remote Controller PAR-CT01 MAU-SB Wired Remote Controller Deluxe MA Wired Remote Controller PAR-42MAAUB Simple MA Remote Controller Ej PAC-YT53CRAU-J Simple Direct Wired Remote Controller PAC-SDW01 RC-1 Wireless RedLINKTM Remote Controller MHK2 Universal Wireless Receiver for PAR-FL32MA-E PAR-FA32MA-W Wireless Remote Controller Lockdown Bracket for Wireless Handheld Remote Controllers RCMKPI CB Wireless Remote Contoller PAR-SL101 A-E Wireless MA Handheld Remote Controller (requires PAR-FA32MA-E) PAR-FL32MA-E Notes IAu Outlet Guide Air Outlet Guide 1 Piece ❑ PAC-SH96SG-E (Iwo pieces required) Centralized Drain Pan Centralized Drain Pan ❑ PAC-SH97DP-E ConlrolServloe Tool ❑ PAC-SK52ST Control/Service Tool Meinto wloo Tool Interface ❑ PAC-USCMS-MN-1 M• & P-Series Maintenance Tool Cable Set ❑ M21 EC0397 Drain Socket Drain Socket ❑ PAC-SG61 DS-E Hail Guards IHad Guard ❑ HG-A2 M•NET Converter M-NefInterface for P-Series 10 PAC-SJ95MA-E 14 Gauge 4 wire Armored MiniSplit Cable250 ft roll ❑ SW144-250 Mini -Split Wire 14 Gauge 4 wire MiniSplit Cable250 ft roll ❑ S144-250 14 Gauge 4 wire Armored MiniSplit Cable50 It roll ❑ SW144-50 14 Gauge 4 wire MiniSplil Cable50 ft roll ❑ S144-50 Mounting Pad Condensing Unit Mounting Pad 24 x 42 x 3 ❑ ULTRILITE2 Optional Defrost Heater 10plional Defrost Heater ❑ PAC-SLt 1 BH-E Snow)Rain Diverter SnowRain Diverter I❑ SRD-5 Outdoor Unit Stand 12 High ❑ OSMS1202M Outdoor Unit 3-14 inch Mounting Base Pair - Plastic ❑ DSD-400P Stand 24 Dual Fan Stand ❑ QSMS2402M 18 Dual Fan Stand ❑ QSMS1802M 3-ft Wiring Harness ❑ PAC-715AD Terminal Signal Adapterr 641in Wiring Harness ❑ PAC-725AD Wind Baffle Front Wind Baffle ❑ WB-PA3 pwo pieces required) Notes rj- 0 (91/91 W 3 (91i6)Z'EI (91iE-Z)99 � cl CBiE)9 (1�£-OZ)S"SZS e — 0 Mull Ir Mkw-ill `8� s i yq� nom ?@j a i8s� _- 90 o :u 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 - mitsubishicomfort com M ETU S_2026-06_P R O P I N G. Intertek Job name: Coffman Ranch System Reference: Flex Space Building Date: GENERAL FEATURES • 208/240V Electric Heat Kits Mounts directly to the air outlet connection of the Multi -position Air Handler CAUTION Do not power the Electric Heat Kit from the outdoor unit. • A separate power supply must be provided. • Air handler must be set on non-combustible floor when using electric heat in the downflow configuration. Maximum external static pressure of 0.60 in WG for all installations with electric heaters. For more details, see note on best design practice on page 3. • This kit must be controlled exclusively using the CN24-1 and CN24-2 (2 stage models) connections on the indoor unit control board. ACCESSORIES Separate Power Kit for MVZ and PVA models This kit allows the installer to connect power from a source other than the outdoor unit to the air handler (S2 $ S3 still must connect from outdoor unit for communication) Auxiliary Heat Lockout for MVZ. SVZ and PVA models This option prevents the electric heat kit from operating above a set outside temperature Replacement Temp Probe for ETC-211020-MIT ❑ SPTB1 ❑ ETC-211020-MIT ❑ 1309007-044 Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved (See note on best design practice on page 5) IS NOTE No other combinations approved other than combinations shown. MODEL PER OUTDOOR UNIT .............moo. Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved (See note on best design practice on page 5) IN NOTE No other combinations approved other than combinations shown MODEL PER OUTDOOR UNIT Electric Heat Kit > > > a a a ¢ N N n m 9 m e a a a a a a _ u-i $r Sr . § . o SS W W W O n m n W W W W W W W W _N W W W Stages (1 ct+2nd) ro '�' y e + T, a a N PVFY-P08NAMU-E1 J PVFY-P12NAMU-E J J PVFY-PI2NAMU-El PVFY-P18NAMU-E J J J PVFY-PI8NAMU-E1 PVFY-P24NAMU-E J J J PVFY-P24NAMU-El PVFY-P30NAMU-E J J J J PVFY-P30NAMU-E1 PVFY-P36NAMU-E PVFY-P36NAMU-El J J PVFY-P48NAMU-E PVFY-P48NAMU-El J J J PVFY-P54NAMU-E PVFY-P54NAMU{1 J J J MVZ-Al2AA4 J J MVZ-Al2AA7 MVZ-A18AA4 J J J MVZ-A1aAA7 MVZ-A24AA4 Air Handler MVZ-A24AA7 J J J Model MVZ-A30AA4 MVZ-A30AA7 J J J J MVZ-A36AA4 MVZ-A36AA7 J J SVZ4(P12NA J J SVZ-KP16NA J J J SVZ-KP24NA J J J SVZ-KP30NA J J J SVZ-KP36NA J J J PVA-Al2AA7 J J PVA-A1aAA7 J J J PVA-A24AA7 J J J J PVA-A30AA4 PVA-A30AA7 J J J J PVA-A36AA4 PVA-A36AA7 J J PVA-A42AA4 PVA-A42AA7 J J J Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC All rights reserved (See note on best design practice on page 5) Electnc Heat Part Number Heater kW Heater Amps' MCA' MOP' Htr B. Mtr Amps' MCA' 20BVI240V 20BVI240V 208V/240V � 20OV1240V 20W1240V EH03-SVZS 2 3/3 0 10 8/12.5 13 5/15 6 15/20 13 2/14 9 16 5/18 6 EH05-SVZS 3 8/5 0 1 B 1/20 8 22 6/26 25130 20 5/23 2 25 6/29 EH08-SVZS 60180 28 9/33 3 36 1/41 7 40145 31.3/35 7 39 1/44.7 EH05-SVZ-M 3.8/5 0 18 1/20 8 22 6/26 25130 21.4/24 1 26 7/30 2 EH08-SVZ-M 6 0/8 0 28 9/33 3 36 1/41 7 40/45 322136 6 40 2/45 8 EH10-SVZ-M 75/10 361/417 451/521 50/60 394/45 4931562 EH03MPAS(B) 2.3/3 0 10.81125 13 5/15.6 15/20 13 2/14 9 16.51186 EH05-MPA-S(B) 3.8/50 18.1/20.8 22.6/26 25/30 20.5/23.2 25.6129 EH08-MPA-S(B) 6 0/8 0 20 9133.3 36 1 /41.7 40145 31.3/35 7 39 1 /44 7 EH03-MPA-M(B) 2 3/3 0 10 8/12 5 13 5/15.6 15/20 14.11158 17 7/19 8 EH05-MPA-M(B) 3 B/5 0 18 1 /20.8 22 6/26 25130 21.4124 1 26 7130 2 EH0&MPA-M(B) 6.0/8 0 28.9/33.3 36.1/41.7 40/45 32 2/36.6 40.21458 EH10-MPA-M(B) 75110 361/417 451/521 50/60 39.4145 493/562 EH10-MPA-L(B) 75110 36 1/41 7 45 1/52 1 50/60 40.6/46 2 50 8157 7 EH15-MPAS-L(B) 11 3/15 Circuit 1 27 1/31 2 33 9/39.1 35/40 31.6/35 8 39 5/44 7 Circuit 2 271/31 2 339/39.1 35140 27.1131 2 33.91391 tH17-MPAS-L(B) 13 2117 5 Circuit 1 316/36.5 395/456 40150 36.1/41 451/512 Circuit 2 31 6/36 5 39 5/45 6 40/50 31 6/36 5 39 5/45 6 EH19-MPASL(B) 14.6/19 4 Circuit 1 35/40.4 438/50.5 50160 42.5/479 531/59.B Circuit 35/404 43.8/50.5 50/60 425/479 531159.8 I Heater amps; no motor 2 Heater and motor amps (connect air handler power supply to largest circuit breaker) Voltage and Amperage based on 60Hz Motor amps are placed on circuit 1 when required Unit tested at 0.60 in WG external static pressure Minimum installation clearance to combustible material 0" Maximum outlet air temperature 200' F The building power supply circuit breaker must be sized per MOP listed for the provided voltage. The factory installed circuit breaker in this kit is provided as a disconnect switch only. Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. X 28.6o & 22o KNOCKOUT TYP 4 42o & 35o KNOCKOUT TYR 3 LINE VOLTAGE 6 1 — E �"l F qlq - �50�4. 77.8 50 (2) TOP VIEW LEFT SIDE VIEW Units: mm (in.) m � N w0 m I RIGHT SIDE VIEW rn v B 29 (1418) CIRCUIT BREAKER S ffi139.3 A N FRONT VIEW MODEL I A I B EH03-MPAS(B) 433 (17) 376 (14-13116) EH05-MPA7S(B) EH08-MPA7S(B) EH03SVZ-S EH05-SVZ-S EH08SVZ-S EH03-MPA1N(B) 534 (21) 477 (18-13116) EH05-MPAM(B) EH08-MPAM(B) EH1NPA-M(B) EH05SVZ-M EH08SVZ-M EH010-SVZ-M EHINPAt.(B) 635 (25) 579 (22-13116) EH15-MPAS-L(B) EH17-MPAS-L(B) EH19-MPAS-L(B) NOTE rQ BEST DESIGN PRACTICE TO ASSURE ADEQUATE REQUIREMENTS During electric heater operation the fan is defaulted to high speed to help assure adequate airflow To maintain adequate airflow required for electric heater operation, it is recommended that an additional 0.20 WG static pressure drop he added to system ductwork design when using the electric heat kit. Examples: When air handler is set for 0.50 WG static, the maxi- mum external static pressure for ductwork should not exceed 0.30 WG. Whenair handler is set For 0 80 WG static, the maxi- mum external static pressure for ductwork should not exceed 0.60 WG, etc. 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-4334822 www.mehvac.com FORM# M_SUBMITTAL_OPTIONAL_ELECTRIC_HEAT_KIT_en - 202206 Specifications are subject to change without notice. © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.