Loading...
HomeMy WebLinkAboutApplication- PermitPone No. 945-8241 Job Address GARF'IELD COUNTY Address BUILDING DEPARTMENT 2014 Blake Ave 9224 Co Rd, 331 Silt Nature of Work Use of Building Owner Residence Residence_ Type Oecupancv Charles and Jag$t Parker Contractor self Amount of Permit $ 127.00 Date November 8. 1978 oR peerkPPg a 1046 G O rl Ne 2120 Owner: Building Permit Application Garfield County, Colo. 1 S 2-1-1 , 1918 Ls - � Amt �� a►e K� i Contractor or Builder: S' L h Location: 9 Z:±1. Purpose for which building is to be used• Size of Lot: • d Si e— Distance of building from property line at: Front 15.0 ' Rear � 011-- Left side Ek) Right side 01111 Distance from nearest building: (PO Number of stories• Source of water supply: c t Al e k Number of rooms: 6 Type of sewage disposal: C"p b`c. 1f 1.-e&C11 Type of foundation. (c ctr•ef-e >i . Width of Building. 2 Material in outside walls: W o D r Length of Building: 3 $ Exterior Finish: L co cf Height of walls: a' Type of roof: ei 5 14e5 ‹Jk,,[ Floor space in sq. ft.: Estimated Cost: $ • fir 000 Date construction will start- _1Ci Date of completion: Jud- �-7 Permit Charge: $ J27 (190 per 1st $1,000 Valuation. $ 4,3 S0 per each additional $1,000 Valuation. TOTAL $ )....7 Dr sD And 1/We hereby agree to build strictly to the terns of the above description, and also to clear the grounds adjacent street or streets of all rubbish and debris caused by the construction of said building. Respectfully, CAL OAL-- The County Commissioners hereby grant the above permit as per terms therein stated. This day of __JY o U F asp / Clerk Building Inspector P., ••••.••• 1-D A 0 ti } I" x < 01 , )idgi.t t rfrOV I`No{i ; \M1v.y•3 h 3fr r k h I r. ,'rs^• CI," 3 �R f O _..`._ C 1 i A q▪ r s .e. le 6p ▪ yo V II" GotiO .00 ' .x:10 PLoaft jotpr 4" _ LlCjpo IP (c�cfr c4 C `6� 11. r ,cru 4 FLOOD 130 CALCULATION FOR WALLS, TABLE W-1 AREAS SQUARE FEET 1. GROSS WALL AREA (Ap) I /d z CAVITY R 2. WINDOW AREA (Ag) i 3/ i 3 6.'" 0/7 3. DOOR AREA (Ad) -5-.3 , / /P . ------------ 4. OTHER (SPECIFY) - e---- 5.. OTHER (SPECIFY)- li, 3 ....__ 6._ OPAQUE WALL AREA (Lines 1-- (2+3+4+5) Aep �� �' - v 147 . ' 7. FRAMING AREA (Afr) (Line 6 x Table W-2; 3,/S -•- F3,15 - . 9*I 8. 8. CAVITY AREA (AC) (Line 6 x Table W-2) 74 q,3 f TABLE W-3 OPAQUE WALL CALC. (FRAMING & CAVITY) • TABLE W-7 TABLE W-2 FRAMING & CAVITY AREAS STUD SPACING (R VALUES) ' FRAMING R CAVITY R 9. OUTSIDE AIR FILM i /7 0/7 10. EXTERIOR FINISH 7, S,, 7, S- 11. OUTSIDE SHEATHING - e---- 12. 12. FRAMING li, 3 ....__ 13. CAVITY (a) INSULATION (b) AIR SPACE °.-- i , Q ! 14. INTERIOR FINISH - . 9*I r,�,_ 15. FIINSIDE AIR LM i ' ZS ILP 2:S 16. OTHER (SPECIFY) .r.----- .. 17. OTHER (SPECIFY) '"-""`" 18. TOTAL BT (Sum Lines 9 thru 17) /3, 6 7 20,21 19. U1 FRAMING " 1/RT ie9 73 ,. 20. 1 U2 CAVITY a. I/RT - r ,l• • TABLE W-7 TABLE W-2 FRAMING & CAVITY AREAS STUD SPACING FRAMING CITY 12" .17 .83 16" .15 .85 24" .10 .90 TABLE W-4 WINDOWS 21. R VALUE 22. U3 A 1/R ' TABLE W-5 DOORS 23. R VALUE 2, /1 24. U4 a. 1/R . �t TABLE W-6 OTHER (SPECIFY) 25. R VALUE 26. U5 = 1/R u 27. R VALUE 28. U6 om 1/R rg FROM COL. A. U COL.B. A FROM COL. C. U x A U1 LINE 19 ,,.07 3 LINE 7 a,4, 7 07 LINE 20 r Ql.iel LINE 8 3647 U3 LINE 22 , 41 LINE 2 izg U4 LINE 24 • ,4 4 . LINE 3 im , 4.1 . US LINE 26 ..-.-- LINE 4 �� U6 LINE 28 --- LINE 5 r,�,_ TOTAL --- J 6 2. / , 135€q7 Uo UTAI + U2A2 + U3A3 + U4A4 +.... A 0 29. Up Wall 7P` TOTAL COL. C. TOTAL COL. B. VS ./3 U0 CALCULATION FOR ROOF -CEILING OUARE FEET 111-n LL n -s nzL.. L.Jp�- 1. GROSS ROOF AREA I S 2. SKYLIGHT AREA ..... 3. ROOF VENT AREA ...-- 4. 4. OT1HER (SPECIFY) `--`..- 5. NET (OPAQUE) ROOF AREA (LINE 1 -- LINES 2,3,&4) leg 6.- FRAMING AREA (LINE 5 x FRAMING RATIO TABLE R-2) I 1. CAVITY AREA (LINE 5 x CAVITY RATIO TABLE R-2) 9 2 V, ? Z TABLE R-3 FRAMING & CAVITY CALC. 8. OUTS IDE AIR FILM FRAMING R ^ CAVITY 9. EXTERIOR FINISH ..... • �-- 10. SHEATHING •_... ECM p--...... 11. FRAMING • 6,64 !""` 12. CAVITY (a) INSULATIOA (b) AIR SPACE r . Iq ,•o' 13. INTERIOR FINISH . +1 6_ t 146` 14, INSIDE AIR FILM .r (p 1 j 4. 1 15. OTHER (SPECIFY) TOTS... *� 16. OTHER (SPECIFY) '-" .,_,,... 17. R, = SUM LINES 8-16 7,6 i., 2000 18. U1 FRAMING = 1/RP , / 3 1 1 19. U2 CAVITY = 1/RT • 0[J -- TABLE R-7 TABLE R-2 OPAQUE AREA RATIOS COL. A U COL. B.11111111111 A COL. C. U X A FROMFROM U1 LINE I� .13 LINE 6 WI ECM , C, 5j 1=111 'q 6 14 .94 REINIMMUIIM EZECIMINIEM TOTS... *� 9' FOB TABLE R-2 OPAQUE AREA RATIOS FRAMING SPACING FRAMING RATIO CAVITY RATIO 12". .13 .87 .16" .10 .90 24" .06 .94 TABLE R-4 TABLE R-5 ROOF VENT , SKYLIGHT 22. R VALUE 20. R VALUE 23. U4 = 1/R = 21. L U3 = 1/R = TABLE R-5 ROOF VENT 24. 22. R VALUE 25. 23. U4 = 1/R = • 4 TABLE R-6 OTHER (SPECIFY) db--'" 24. R VALUE 25. ,U5=1/R= U0 = U1A1 + U2A2 + ... A TOTAL COL. C. _ V°ROOF-CEILING TOTAL COL. B. _ _ r . o CALCULATION FOR FLOOR .. I ARIAS SOUARE.FEET TABLE F- 1. GROSS FLOOR AREA . FRAMING 19V R 2. FRAMING AREA (LINE 1 X FRAMING RATIO TABLE F-2) -- 7e. e , 7. EXTERIOR FINISH 3. CAVITY AREA (LINE 1 X ' CAVITY RATIO TABLE F-2) ;.0 7/ V1 * 2 /J,5-4. 4. OTHER (SPECIFY) .. 1 b% 110 3 • 6,67e 5. OTHER (SPECIFY) • i ..---• ! 12. INSIDE AIR FILM [--- r - 13. OTRER (SPECIFY) TABLE F-3 FRAMING AND CAVITY CALCULATION - . . FRAMING CAVITY R R 6. OUTS IDE AIR F ILK -- FROM 7. EXTERIOR FINISH "..--• U1 LINE 16 ;.0 7/ 14 FRAMING /J,5-4. '"` 9. CAVITY (a) INSULATION ' - (b) AIR SPACE 1 b% 110 3 • 6,67e i0. DECKING g3 1 ,q5 11. FLOOR FINISH , 14 .q4 .- 12. INSIDE AIR FILM [--- r - 13. OTRER (SPECIFY) # --„_. 14. OTHER (SPECIFY) 15. RT .. SUM LINES 6-- 6-14 . !41611'3.1'e 16. Ul FRAMING .1 1/RT #071 �.. ' .07q 17. U2 CAVITY - .1/RT TABLE F-6 • COL. A. . COL. B. COL. C. - - • U. A U x A - FROM .87 .90 .94 FROM U1 LINE 16 ;.0 7/ • LINE 2. -700 1 LINE 17. 1 b% LINE 3 • 6,67e 1_U3LINE 19 1 .-..-. LINE 4 U4 LINE 21 "'""'�". LINE 5 -- I TOTAL ' • 10 72,0 (, TABLE F-2 FRAMING S CAVITY AREAS OPAQUE AREA RATIOS JOIST SPACING FRAMING RATIO . CAVITY RATIO - 12" • 16"' 24" . .13 .10 • .06 .87 .90 .94 TABLE F-4 OTHER (SPECIFY) - y 18. R VALUE 19. U3 - 1/R .(combine 3) TABLE F--5 OTHER (SPECIFY) 20. R VALUE Ua U1AI + U2A2 + ... A a so TOTAL COL. C. Uo Floor TOTAL COL. B. E -S •,71 Dote !!! �2- �3/ 8 • Ime / GARFIEED COUNTY STATE OF Colorado Office of Building Official REQUEST FOR INSPECTION A.M. ece1ved P M Job Ad rens Owner's BUILOIN 'rounds tion Chimney Frgrning final 0 Mon. Inspection Ma Inspector issaiA 300.1 PLASTERING Wire 0 Lath 0 Scratch 0 Brown 0 Finish 0 wallboard 0 Permit No District PA"- Locality Contractor ELECTRICAL Rough Wiring .0 Finish Wiring❑ Fixtures ❑ Motors. 0 PLUMBING Rough ❑ Final ❑ Sewers 0 Gas 0 Cesspool ❑ ...READY FOR INSPECTION �ues ed. Thu 0-7 80 HEATING Rough ❑ Final 0 Water Heater0 A.M. Fri. P M 2 jeCr`�`t. .�.S Date "30 ` TTimepeievecf : 3 O CA- R �,1. Job Adtlre �`. GAR F I ELD COUNTY '1x10 -Q%4 TATE OF Colorado 4.p Office of Building Official REQUEST FOR INSPECTION 14' ! _ Permit No to bwrier's am ILDIN PLASTERING f Qundatlon 0 wire 0 Chimney D Lath 0 gaming Scratch 00 l Ina! Brown Finish 0 Wallboard 0 tri READY FOR INSPECTION District No Locality Contractor ELECTRICAL Rough Wiring .0 Rough gRough 0 Finish Wiring.. 0 Final Final Fixtures 0 Sewers 0 Water Heater.. 0 Matars. ❑ Gss Cesspool 0 OR inspection ,[nspector 44RMsDD.1 Tue Wed. Thurs. Fri. r9 4' 7 Permission is hereby granted to RESIDENTIAL CERTIFICATE OF OCCUPANCY BUILDING DEPARTMENT GARFIELD COUNTY, COLORADO Charles P.. & Janet G. Parker Issued Without Fee • June ZP ig8O Building Permit No 1 Zone District situated at ".' • • . , I.:31 Lot for the following purpose iii4414;414 Percent of Completion lOri.% . TAKE NOTICE No *lenge shall be made in the use of this building with- out !Mar notice and certifi- U cote from the Building Official, OWNER'S Blk. Addition IStat e Nature of Use) GARFIELD COUNTY BUILDING DEPARTMENT By eo. Job Aess • POST THIS CARD AT OR NEAR FRONT O BUILDING .r_ GARFIELD COUNTY • Nature of Work BUILDING DEPARTMENT 40. I N S P E. C T1s 'O N R E C, O R D ':o t, Use of Building • i #ddress 2014.: Blake Ave n.. N2 Ocollpincy Oi r CiAr1cF send ,rant Parker Contractor ; c4 f ' . Amount of Permit $ I27.00 NOTE: Date November L. 1978 ALL CHECKS MUST BE MADE PAYABLE TO GARFIELD 00. CLERK & RECORDER Inspector must sign all spaces pertaining to this Job INSPECTION DATE JPOPECTIK . Foundations: Setback Trench Reinforcing Foundation Wall and Weather Proofing Pour no concrete until above hast been si Concrete Slab Floor Electrical (Groundwork) p-, Plumbing (Groundwork)_ Brown Coat _ Gas Piping (Groundwork} Finish Coat d. Wallboard Do not pour floor until above has been signed Rough Electrical Rough Plumbing Rough Gas Piping Rough Heating and Ventilation (Above must be signed prior to framing inspection) Framing air 5-17/90 Cover no work until above has been s gned Lath and Plaster (Interior) Lath Scratch Coat Brown Coat Finish Coat . 4 Wallboard Lath and Piaster (Exterior} Lath Scratch Coat Brown Coat Finish Coat; , Miscellaneous Roofing . Sewer Refrigeration Electrical Underground _ • II►. Final Electrical Fixtured Plumbing Fixtures 14s,.. Gas Piping Heating and Ventilation . Job Completed �. FORM 300.2 4 to 46