Loading...
HomeMy WebLinkAbout4003 r 940093 i GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81801 (303) 945-8212 Job Address Lot 9 Sec, 7- T83 R8 M G G.r 2-My Py Nature of Work BLU.lCainq Permit Use of Building s/E ies• Owner D viu C. Lkgjell Contractor OWTX-r Amount of Permit: $ 5.32.95 Date; 7/11/90 323.00 Permit 209.95 Plan Haring Clerk White - Treas Canary - Office Pink - Applicant Gold - Duplicate • " ! y l i l 9 I y' { I V. J� l `T Y y � � s 'f .. J .� / t +, :. „ 1 1IT NUMBER OWNER A,07,4) A,477 m il/ ADDRESS L ev /1� c 7 9 ce (; 7 - 75 /e S 9 W )H Y /LA FOLLOWING OLUEWING ITEM% HAVE EITHER BEM OMITTED F'RCM YOUR PLANS OR y3C7 NOT COMPLY WITH THE 'II PROVISIONS OF TlIE UNIFORM BUIIDINC CODES. PLEASE CHECK ALL X'D ITEMS BEFORE BEGINNING CCNSTRUCI'ION_ ALL REFERENCES ARE 1982 UBC UNLESS OTHERWISE NOTED. 1. Structural concrete for footing and foundations and load bearing slabs on grade is required to be 3000 PSI within 30 days. 2604 (c) E and standard 26 -1. (2) Reinforcenent steel for footings: 21k4 rebars continuous. ���•� Reinforcement steel. for foundations: 2H4 rebar at top aril bottom of wa11.4'c.+e cc,�cr ever L'-� Frost protection for footings: 30" minimum to the 'rop of the footing. 2907 (a). CQ Foundations shall extend at least 6" above grade. 2907 (a). (52 Provide for the drainage of surface /runoff water away from the building. 2905 (f) ° 6. Foundation plates on mid sills shall be redwood or pressure treated wood. 2516 (c) Foundation plates shall be bolted to the foundation with anchor bolts a minu tmi 1/2" x 7" - 6' on center; 1./2" x 15" in unreinforced grouted masonry. 2907 (e). /'e t2 solid blocking is required between joists at all bearing points. 2517 (cl) 3. 9. With joists @ 24" on center: minimum plywood thickness allowed is 3/4 ". Table 25 -R -1 -ter 10. Joists are insufficient for the spans: Minimum x -o.c. Table 25 -U-J -1 11. Bean insufficient for loads /spans x MINIMUM size allowed. Tables 25 and 2304 12. A glu -lam or a steel beam is required at Tables 25 and 2304 13. All walls bearing two floor loads are required to be a mi inmun of 3 x 4's or 2 x 6 studs with a maximum spacing of 16" on center. 2518 (g) 1,3 14. Shear bracing required: both sides of each corner and•every 25 lineal feet. 2518 (g) 15_,Bric]c ties; 1" x 22 gauge, spaced a minimum of 16" on center each way. UBC standard 3( 16. ceiling /floor headroom is required to be a minimum of 7'6" in all rooms except kitchen: halls, bathrooms and storage areas which may be a minimum of 7'0 ". 1207 (a) Cl Mininnmr stairwell headroom measured from the nosing of tread is 6'6 ". 3305 (p) 18. ALL STAIRS: MAXIMUM rise 7 -1/2 "; MINIMUM run - 10 "; MAXIMUM over-all variation within a flight of stairs is 3/8 ". 3306 (c) (RESIDENTIAL EXCEPTION -8" rise & 9" trey 19. Minimum width of stairways in a single - family dwelling is 30 ". 3306 (b) 20. Handrails: minimum height - 30 "; maximum height - 34 ", handgrip portion shall be not ' less than 1 -1/4" or more than 2 inches in cross sectional area. 3306 (j) 21. Residential guardrails: minimum height - 36 ". Open guardrails and stair railings shall have a pattern such that a sphere 6" in diameter cannot pass through. 1711 EXCEPTION - ISOLATED COMMERCIAL MAY BE 12 ". j 22. Underfloor /crawl space ventilation is required. 2516 (c) 6 23. Access to underfloor areas shall be a minimum of 18" x 24 ". 24. Windows in unfinished basements: 4'x 4' with a maximum sill height of 44" or area used for storage only and plans marked "STORAGE AREA ONLY ". 1204 (Item 26, below) 5'. Windows located within 18" of the floor and 18" or wider are required to be tempered or protected. 5406 (d) 6 & 7 - nn tf acyde r h f /0 a r/onr J2 .,EVERY bedroom below the 4th floor without a door opening to the outside shall have at least one window that meets the following requirements: MAXIMUM sill height: 44 inches ;, ; MINIMUM net clear opening width: 20 inches MINIMUM net clear opening height: 24 inches MINIMUM net clear opening: 5.7 square feet 1204 27. Provide combustion air for furnace /water heater. UMC 607 (28.? Provide floor drain for water heater or pipe P & T relief valve to the outside of the building. UPC 1007 29. Furnace and water heater must each be removable without moving the other. UMC 703 30. Each water closet shall have minimum clearances of 24" in front and 30" width (15" center line to nearest sidewall). Section 511 • 31. Bathrooms without windows shall be equipped with a fan vented to outside air. Section 32. Attic access required; minimum opening: 22 x 30 inches. 3205 (a) 33. Fireplace hearth: minimum depth in front of opening is 16", sides 8 ". 3703 - 3704 34. Attic ventilation required; rnini.rrnnu 1/150th of the vented space. 3205 (c) C.2 One hour firewall with a selJ_glosing8" solid core door is required between the � house and garage. 503 (d) 4 V A "wired in" electrical smoke detector is required in all bedroan access areas; for second story bedrooms, locate the detectors at the top of the stairway. Any other alarm trips other alarms. Sazie applies to a basement. 1210 (a) 37. Headers over doors and windows will be on edge. Section 2517 (g) 5 38. ll 39. - puvn CAL P.o -1 P/u rl 40. 41. 42. 43. 44. 45.