HomeMy WebLinkAbout4176 • of extended to the exterior of the building - UPC Sec. 1007. 45. Domestic dishwashing machines shall not be directly connected to a drain or waste disposer without the use of an approved airgap - UPC Sec. 608 (d). 46. Fuel burning appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed space opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless listed for such use). 47. Appliances (including space heating and water heating equipment) shall be accessible for repair and removal in accordance with the UMC. 48. LPG fueled appliances shall not be installed in a pit, under -floor (crawl) space, or basement - UMC Sec. 504 (f). .49) Appliances located in a garage (or in an enclosure opening into a garage) shall be located out of the normal path of vehicles or protected from damage. Any portion of the appliance creating a flame, spark or glow shall be installed a min. of 18" above the garage floor - UMC Sec. 508. 50. Each water closet stool shall be located in a clear space not less than 30" in width and 24" in front of stool - UBC Sec. 511 (a). (51.1 Toilet rooms without operable windows shall be equipped with an exhaust system ducted to the exterior - UBC Sec. 1205 (c). 52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbent surface to a height of 70" min. above the drain inlet - UBC Sec. 510 (b). Water- resistent gypsum board shall not be used over vapor barriers, in saunas or steam rooms, or on ceilings - UBC Sec. 4712. (53) Attic access opening of not less than 22" by 30" is required - UBC Sec. 3205 (a). 30" by 30" if mechanical equip. in attic space - UMC Sec. 708. ("53. Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150 - of the area of the space ventilated. The area may be 1/300 if provided equally at lower and upper portions of the space with min. 3' vertical separation of locations - UBC Sec. 3205 (c). 55. Garage side of common wall between living space and garage shall be finished with materials approved for one -hour fire - resistive construction. This also applies to ceilings and bearing walls if living space above the garage. Self closing min. 1 3/8" solid door is required between house and garage---- - UBC 503 (d) 3. (56':) Electrically wired, interconnected smoke detectors are required in all " sleeping room access areas, near the top of stairways in upper levels, and near the bottom of stairways to basements - UBC Sec. 1210 (a). , 57 Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UBC Chapter 37. 58. Masonry and concrete fireplaces and barbecues shall meet the requirements of UBC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed as a supporting member - UBC Sec. 3703 (a). 59. • 60. COPIES OF THE ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items above or below are available upon request). Excavations, fills, foundations, and retaining walls - UBC Chapters 23 and 29. Retaining walls - UBC Sec. 2308 (b) and 2907 (g) 4. ___ Roof coverings and drainage - UBC Chapter 32 (Roof drains sized in accordance with UPC Appendix D). Roof sheathing - UBC Sec. 2516 (i). Wood combined with (supporting) masonry or concrete - UBC Sec. 2515.. Floor sheathing - UBC Sec. 2516 (h). Wiring in plenums - UMC Chapter 10 and NEC. Fire and draft stops - UBC Sec. 2516 (f). Nailing requirements for connecting wood members - UBC Sec. 2516 (j). Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish chutes - UBC Sec. 1706. Exterior wall coverings and exterior weather protection - UBC Sec. 1707 (d) and 2516 (g). Interior application of gypsum wallboard and interior and exterior application of lath and plaster - UBC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. Landings and floor level at doors - UBC Sec. 3304 (i). Cross connection control and back flow prevention - UPC Sec. 1002 and 1003. Treated Wood Foundation Systems - UBC Standard 29 -3.