HomeMy WebLinkAbout00251 • v _ This does not constitute a building or use permit. GARFIELD COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH 2014 Blake Avenue Glenwood Springs, Colorado 81601 INDIVIDUAL SEWAGE DISPOSAL PERMIT NY 251 REPAIR AND EMERGENCY USE PERMIT Owner Mr. & Mrs. Alfred Drayton System Location 452 W. 11th - Rifle, Colorado 81650 Licensed Contractor owner existing Conditional Construction approval is hereby granted for a l , 000 gallon r ,. X Septic Tank or Aerated treatment unit. Absorption area (or diapersal area) computed as follows: Perc rate of one inch in 14 minutes requires a minimum of 185 sq. ft. of absorption area per bedroom. Therefore the no of bedrooms 3 x 185 sq. ft. minimum requirement = a total of 555 sq. ft. of absorption area May we suggest iosoecti n be conducted (lyri } R te month 1976 t determin the Date xlRl ln pp�1 g& e iT ie ec aty/ ltemTheAfl?'n naa1 °recommeennoat90Reor#con!iusion r wl r0 1On he (Permit Gb t issuance approved by the Garfield County board o health FINAL APPROVAL OF SYSTEM: •111 their meeting of March 8, 1976.) ,RS/ No system shall be deemed to be in compliance with the Sewage Disposal Laws until the ks'efnbled system is approved pri r to cover- Ing any part. ' Septic Tank cleanout to within 12" of final grade or aerated access ports above grade. +� e'` Proper materials and assembly. Trade name of septic tank or aerated treatment unit. 42-"K---- Adequate absorption (or dispersal) area. Adequate compliance with permit requirements. 6 " compliance with County and State regulations /requirements. Other _ `�5 Date 0 /'/ 7‘o• Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All installation must comply with all requirements of the County Individual Sewage Disposal Regulations, adopted pursuant to au- thority granted in 66 -44 -4, CRS 1963, amended 66 -3 -14, CRS 1963. 2. This permit is valid only for connection to structures which have fully complied with County Zoning and building requirements. Connection to or use with any dwelling or structures not approved by the building and Zoning office shall automatically be a viola- tion of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.24 requires any person who constructs, alters, or installs an individual sewage disposal system in a manner which in- volves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6 months in jail or both. Building Official — Permit White Copy Applicant — Green Copy Dept. — Pink Copy FOR EMERGENCY USE Fees Paid $ INDIVIDUAL DISPOSAL SYSTEMS APPLICATION • Date NOTIFICATION OF PROPOSED DISCHARGE TO WATERS OF THE STATE* INDIVIDUAL HOME SEWAGE TREATMENT SYSTEM ** Owner: I/ /ire d q/9/ ( t //o h Mail Address:/7),t0/ / >2,`i a- City: '67 p_, Zip: f /k71 Phone: / ? oS - . y INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable buildings, location of potable water wells, soil percola- tion test holes, soil profiles in test holes. 1. Location of facility: County 0 p ,/✓ City or Town Legal Description - Lot Size o7 '/7 2. No. of Bedrooms 5 Septic Tank Capacity /,, Aeration Unit Capacity 3. Source of Domestic Water: Public (name): 50/ (/' Private: Well Depth Other Depth to first ground water table 4. Is facility within boundaries of a city /town or sanitation district? it ,, 5. Distance to nearest sewer system: 4c„:? Have you attempted to arrange a connection with the system? 6 1 If rejected, what was the reason? 40 , P / /.// 6. Rate of absorption in test holes shown on the location map, in irRJs�p teerjnp)?, of �, N,i drop in water level after holes have been soaked for 24 hours: a `'' " 7. Name, address, and telephone of person who made soil absorption tests: 0J 4; if ( New /!A ), 8. Name, address, and telephone of person responsible for design of the system: 9. Express permission is hereby granted for the inspection of the above property by any member of the Garfield County Environmental Health Department and /or such persons as they may designate. Any withdrawal of this permission shall be in writing and receipt acknowledged by the County Environmental Health Department. 10. I have been given an opportunity to read the Individual Disposal Systems Regulations of Garfield County and I hereby agree to comply with all terms, conditions and requirements included therein. Date igna o o f O wner (TO BE RETURNED TO HEALTH DEPT.) March 8, 1976 Mr. and Mrs. Alfred Drayton P. 0. Box 1252 Rifle, Colorado 81650 Dear Al and Carol: In their meeting of March 8, 1976, the Garfield County Board of Health unanimously approved the issuance of the enclosed Repair and Emergency Use Permit for your individual sewage disposal system. I'll be in touch with you the first part of May to arrange for a date to further check the water table in the immediate vicinity of the leaching area. Should you have any concerns, please give me a call. Very truly yours, ENVIRONMENTAL HEALTH DEPARTMENT Edward L. Feld Acting Department Head ELF /tls encls. ./ COLORADO DEPARTMENT OF HEALTH DIVISION OF ENGINEERING AND SANITATION A C T I V I T Y R E P O R T Code :[ion Sewage County Garfield FILE REFERENCE: _ Individual Home Sewage Disposal INDIVIDUAL OR ESTABLISHMENT: Alfred Drayton ADDRESS: _ 452 W. llth - Rifle,'Colorado 81650 NARRATIVE: — — 11:20 A.M. - This inspector arrived on the Alfred Drayton property for the purpose of observing an 8 foot profile excavation and inspection holes in order to determine if the individual subsurface sewage disposal area complied with the requirements of the Garfield County Individual Sewage Disposal Systems Regulation. Observations are as follows: 1. Ten foot profile hole had been dug. (a) Standing water was observed at the 8 foot level. (b) Seeping water was observed at seven foot level. (c) No fluorescein dye was observed. (d) Water was not discolored. (e) No septic odor noticed. (f) Mr. Drayton stated the profile hole had been excavated on Sunday, August 31, 1975, and he first observed water on September 2, 1975. 2. Inspection holes were dug in the presence of this inspector at the far ends of the outermost laterals. (a) Septic tank effluent of a dark (black) discoloration was observed at approximately the two foot level. (b) Definite septic odor noticed. (c) 1 1/2" to 2 1/2" aggregate observed in the trenches. (d) Four inch PVC perforated pipe observed. (e) Aggregate under the pipe was in excess of 6 inches. (f) Aggregate over the pipe was over 2 inches in depth. (g) Generous amount of hay was observed between the aggregate and earth cover. (h) Mr. Drayton stated he had installed 180' of absorption trenches in three laterals 3' wide and 4' deep with 18" of aggregate under the pipe. • ETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: DATE: , 19 REPRESENTATIVE- S: 7 (Rev. 6 -70 -100) 77. COLORADO DEPARTMENT OF HEALTH DIVISION OF ENGINEERING AND SANITATION Page Two / A C T I V I T Y R E P O R T Code on Sewage County Garfield FILE REFERENCE: Individual Home Sewage Disposal INDIVIDUAL OR ESTABLISHMENT: Alfred Drayton ADDRESS: 452 W. llth - Rifle, Colorado 81650 NARRATIVE: continued 3. A 2' wide, 8' deep, 50' plus long subsurface irrigation water diversion dam had been constructed with 3 tons of bentonite and a plastic curtain extending from top to bottom along the entire length according to Mr. Drayton. (a) An inspection hole dug in the presence of this inspector into the dam revealed the plaster and a sticky, grey, clayish substance believed to be bentonite. Conclusion: C • 1. Based on the trenches being 4' deep and seeping water being observed at the 7' level, only 3' of permeable soil existed between the bottom of the trenches and the water table at the site of the observed 10' profile hole. It should be noted however that if the minimum required 3' deep trench had been installed, a four foot strata would exist•between the bottom of the trench and the present water table. Two other points must be considered: (a) When is the maximum ground water table at its height - during the summer irrigation months or during the spring run -off? (b) Due to the lower elevation of the 10' profile hole provided, are the three existing laterals situated at slightly higher elevation within the required 4' of suitable soil strata between the water table and bottom of the leach lines. It would be this inspector's request on point (a) to again observe an 8' profile hole during the Spring of 1976. It would also be requested by this inspector to have the leach- ing area surveyed by a registered land surveyor and those results presented to this office to determine if one or more of the laterals are in compliance in relation to the grade and water table. 2. Proper materials had been used and assembly was satisfactory. Mr. Drayton's • figures of 180' of leaching trenches 3 feet wide would provide 540 square ETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: • D ATE: , 19 REPRESENTATIVE: a e.. �_�n -S OD) - Page Three L - COLORADO DEPARTMENT OF HEALTH I • DIVISION OF ENGINEERING AND SANITATION A C T I V I T Y R E PORT Code scion Sewage. • County Garfield • FILE REFERENCE Individual Home Sewage Disposal INDIVIDUAL OR ESTABLISHMENT: Alfred Drayton ADDRESS: _ 452.W. 11th - Rifle, Colorado 81650 • NARRATIVE: continued feet of absorption area. Based on the results of the percolation test conducted 8- 27 -75, a minimum of 555 square feet of absorption area would have to be provided. (perc rate 1" in 14 minutes = 185 square feet of absorption area per bedroom. Three bedrooms x 185 = 555 square feet minimum requirement.) In order to comply with this requirement, a three foot extension of one of the laterals would be necessary. • • • v ' ETTER TO FOLLOW: ( ) OTHER RECOMMENDATIONS: SATE: September 3 , 19 75 . REPRESENTATIVE: Edward L. Feld, Deputy Sanitarian 1 -E .9e-436- oR 4Y TDA/ \ i • Sc: F .. fr ?/tr / T / f,A / c-ED 6- 1/f-7,e, GARFIELD COUNTY • ENVIRONMENTAL HEALTH Glenwood Springs, Colorado 81601 2014 Blake Avenue Phone 945.7255 September 18, 1973 Mr. A. Drayton Box 1252 Rifle, CO 81650 Dear Mr. Drayton: Mr. Kinkade and Mr. Feld from the Garfield County Environmental Health Department conducted a third field inspection for your in- dividual home sewage treatment. Our findings: The property is unsuitable for a standard septic system for the following reasons: 1. No perculation rate. 2. Lack of usable area. 3. Proximity of natural springs. 4. Surrounding terrain. Our suggestions for possible alternatives are as follows: 1. Annex the property to the City and connect to the City sewer line. 2. Provide for a sealed holding tank that would have to be pumped and removed on a regular basis. 3. Have aRegistered Professionsl Engineer custom design a system and submit it to our office for approval. 4. Install aerated treatment unit (1000 gallons plus) with 350 square feet sand filter bed (of approved design) and chlorination contact chamber (200 gallons plus) with surface discharge. r 5. Construct house on top of hill and use present building site for a 3000 square foot Nordak Evapotranspiration bed. Inform us please of your choice of alternatives and we will assist you in any way possible: Sincerely, Ed Feld Garfield County Deputy Sanitarian Lamont Kinkade a i "O rfield Oounty :.'. r bi "cc tor. of Environmental Health • 4 r ! • • r.— • • /'7 7973 /ve - I�/2l9YTL�A /C/iv /ei920{ 6i5 �iG -zdJ sry 4'v /,eoN nt 6-ate te _ cO.✓OUcnazD 77W.eO 1'/ e� YOcv //V 0/el/Dales• /7 sSZv *" 7 en- e✓ T. oe/2 No /Nca5 nthr— P2o, —ry /s u/Use,/ e s 7-7.771/4) .1 se 77c- s Ys rte j ,'2 77/x8 roc-« -v /4v:, /ze - s.c J, /O "e-2e—mac C-49T7D esI ,'2- rrr z . ,C �Ls7 3. P/lflxir' / O/— /V /1 � s/c2/i06S h! su/L,em V //vim retWare-r .J(.7/2- 5Cl/p1v /OACS ec42- ,oSf / !ft rat* - 7- //J� AJC- caae->s r �irY /. / y- ^/ /t/n 7.—car ,� 'O&p 7� eON /vt GT'' Tl7 G! r / stz[ >a c- c5 z' /4/z&v /Ov 1co /9 5& n -6 "7> /79 Tr/W Celtatee-d /`f/f'C 7e° 8 S' "elm . C; # /2c'7°7oUe–Y, 0A/ /r ,egc tec /4–S /s, 4 C €/a re: 7 DtE /d2/v /5 S V 5r��! /1 ate /r / r / r' 727 OCt a/c c/C c , c ' - /9 , Wvc 7 / en ell/ r ten 0000 ' 1OGUS e-e"n t 3�o SQ , s T71/,O fc / G7et- ,Bez (of- y 9A/7- ) De3 / .9 �N Tn--T Gff79�9 i CSC ev . / ct t1c) 0 / 7-7-74" 5 ate CfC- ' ,O /sc-/Y7972a' s ■ O/pic/ 1r /fv0sc -- cw 1 > ®,C /ter C' .E p2Csa7Vr/✓4 /v0 / , s /rte /` �. ccc ` • / = r ,UO20'9'.c- CZ/..9,ce,7 sr i7O.tJ "eV, /4) AV &lfl ce S /°GS71Sc O/c Yd u CA`r`o/ c-= O -� /9 6 ,moo 4.0S a/� 3/412--e-/ /4/ f Y w�1 ©55 /,BLS eraece 1, ..J F OLORADO DEPARTMENT OF HEALTH 'Water Pollution Control Division • 4210 East llth Avenue Denver, Colorado 80220 PLEASE PAL OUT /14)0 r TOfl) wiTH * 25, eo t cNe it APPLICATION FOR APPROVAL OF LOCATION FOR SEPTIC TANK SYSTEMS Applicant (Owner): R1L 0 a Ri"T( Mall Address: !3 1;2._ 6 City: /eIF„L_p Phone:/a5" A. INFORMATION REGARDING PROJECT SUBMITTED FOR REVIEW: Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable buildings, location of potable water wells, soil percolation test holes, soil profiles in test holes. 1. Location of Facility: County 0,q ,p {i r_Jr) City or Town Legal Description Lot Size: -? fa 2. Type of area and facility - Number of persons served: Subdivision Motel Restaurant Trailer Court Other: Nn, nF 16eogQ2'n5 4in a , . 3. Source of domestic water: Public (name): /1,9,,) i,i4 7r}7 Private: Well _ Depth _ Other _ Depth to first ground water table 4. Is facility within boundaries of City or Sanitation District: AN, If so name: 5. Distance to nearest sewer system: 74n 1 /. Have negotiations been attempted with owner to connect: If rejected, give reason: 6. Rate of absorption in test holes in minutes per inch of drop in water level after holes have been soaked for 24 hours: 7. Name, address and telephone of person who made soil absorption tests: 8. Name, address and telephone of person responsible for design of the system: 8r,/3 Pi /2 . ‘i . if) - /.f, ( /.r /,rs /f/ %q 9. Est. bid opening date: _ Est. Completion Date: Project Cost:fj.„-,2 Date: (237,.t /T1/ /7) ,r - -- Si nature Owner B. SIGNATURES FOR LOCAL GOVERNMENT OFFICIALS: The undersigned have reviewed the a 4. , proposal for the location of the above- described septic tank system and RECOMMEND APPROVAL or DISAPPROVAL in the space provided below: DATE APPROVAL DISAPPROVAL /----7 / —/ Signature for Local Health Department / -/ / —/ Signature for Mayor or City Manager Signature for County Commissioners Comments: - Signature and Title Note: The applicant must obtain the comments and signature of at least one of the above. C. FOLLOWING FOR STATE HEALTH DEPARTMENT USE: Recommendations of the District Engineer D. ACTION BY THE COLORADO WATER POLLUTION CONTROL COMMISSION: WP -10 (Rev. 5 -70 -100) 11/4 ice. ,,, 00.%*