Loading...
HomeMy WebLinkAbout01503 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 Phone (303) 945-8212 This does not constitute INDIVIDUAL SEWAGE DISPOSAL PERMIT - 1,503 a building or use permit. Owner nonnevi1le Pacific Corporation (for Co- Generation) System Location 1 1 • • , :: - ''. • - .. Licensed I nstaller _ Project Construction Corporation • Conditional Construction approval is hereby granted for a gallon Septic Tank or ___Aerated treatment unit. . • Absorption area (or dispersal areal computed as follows: t Perc rate of one inch in _ minutes requires a minimum of sq. ft. of absorption area per bedroom. Therefore the no. of bedrooms x sq. ft. minimum requirement = a total of sq. ft. of absorption area. May we suggest: ENGINEF SYSTEM. PLANS AND SPES ATTACHED. � Date I nspect° /7/4. 0C,'. /�:' FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to cover- ing any part. 0° \ - Septic Tank access for inspection and cleaning within 12" of ground surface or aerated access ports above ground O /„ surface. f'� (— Proper materials and assembly. / /^ �f \ T rade name of septic tank or aerated treatment unit. Gone / �,,.t1 a b Q c (OK Ce (two) e9 F Adequate absorption (or dispersal) area. 7/432,4 L. /- / O 4j Adequate compliance with permit requirements. A.14- — Adequate cornpliance with County and State regulations /requirements. A i; Date __ 2 e i.6 . /mil. _ Other / %/J� -- - - - -- - - Inspector /" - -�� a` -f— - RETAIN WITH RECEIPT RECORDS ,/'CONSTRUCTION SITE "CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which Involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 8 months in jail or both.). Applicant: Green Copy Department: Pink Copy II 1NUIVIUUML StWAIit UISI'USAL SYSILM API'LICAIION 'Approval oy OWNER Bonneville Pacific Corp. County Officio II ADDRESS 200 East South Temple, Salt Lake City84111PHONE (801) 363 -1900 CONTRACTOR Project Construction Corp. ADDRESS 560056 - 352 Rd. Rifle, CO 81650 PHONE (303) 625 -0148 ' PERMIT REQUEST FOR: ( X) New Installation ( ) Alteration { ) Repair Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes. (See page 4.) II LOCATION OF PROPOSED FACILITY: County Garfield (- ' Near what City of Town Rifle Lot Size 41.33 Acres + Legal Description See attached description WASTES TYPE: ( ) Dwelling ( ) Transient Use (X ) Commercial or Institutional ( ) Non - domestic Wastes ( ) Other - Describe BUILDING OR SERVICE TYPE: Warehouse and Electrical Generator Building II Number of bedrooms --- Number of persons 50 ( ) Garbage grinder ( ) Automatic washer ( ) Dishwasher III Give AND TYPE OF WATER SUPPLY: ( ) well ( ) spring ( X ) stream or creek Give depth of all wells within 180 feet of system: No wells within 180 feet II GROUND supplied by community water, give name or supplier: - -- GROUND CONDITIONS: R bedrpck :,.. Approximately 16 feet ' Depth to first Ground Water Table: Not found Percent ground slope: Approximately 1% II DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: Over 2 miles Was an effort made to connect to community system? Yes I TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (X ) Septic Tank ( ) Aeration Plant ( ) Vault ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use 1 ( ) Pit Privy ( )Incineration Toilet ( ) Recycling, other use II ( ) Chemical Toilet ( ) Other - Describe: FINAL DISPOSAL BY: (X ) Absorption Trench, Bed or Pit ( ) Evapotranspiration ' ( ) Underground Dispersal ( ) Sand Filter ( ) Above Ground Dispersal ( ) Wastewater Pond ' ( ) Other - Describe: IILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? No 1 1 '. Page 2 ;OIL PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer.) ' Minutes 4.4 per inch in hole No. 1 Minutes 8.6 per inch in hole No. 3 Minutes 6.2 per inch in hole No. 2 Minutes 4.0 per inch in hole N0,4 I Name, address and telephone of RPE who made soil absorption tests: Alex Stansen Stearns Catalytic P.O. Box 5888, Denver, CO 80217 '(303) 758 -1122 Name, address and telephone of RPE responsible for design of the system: Alex Stansen Stearns Catalytic P.O. Box 5888, Denver, CO 80217 (303) 758 -1122 I Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for I purposes of the evaluation of the application; and the issuance of the permit4s'subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations adopted under Article 10, Title 25, C.R.S. 1973, as amended. The undersigned hereby certifies that all statements made, information and reports submitted herewith and required to be III by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further under- !' stand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal a ion for per- jury as provided by law. ' Date Y Ma 29, 1986 Signed a 071/ 1 PLEASE DRAW AND ACCURATE MAP TO YOUR PROPERTY See Attached Plot Plan 1 1 1 1 1 1 1 1 Page . 3 II ' PLOT PLAN AND DESIGN FEATURES: I Include by measured distance location of wells, sphings, potable water supply lines, cisterns, buildings, property lines, subsoil drains, lake, water course, stream, dry gulch and show location of proposed system by direction and distance I from dwelling or other fixed reference object, and additional submissions in support of this application such as data, plans, specifications, statements and commitments. 1 See Attached Plans & Specs 1 1 1 1 1 1 . 1 1 1 1 1 1 1 1 Page 4 . Catalyt 1••• 1 Client CTDC Job /Inquiry No. C -2R314 hefty: American Atlas #1 Spec. No. A p'8 Location: Rifle, Colorado PROJECT SPECIFICATION SANITARY SEWERS 1 This title page is a record of all revisions of the specification. Each time the specification is changed, only the new or revised pages are issued. For convenience, the nature of each revision is briefly noted below. 1 Rev. No. Date By Approval Approval Pages Nature of Revision 1 A 05/29/86 JSC all For Approval 1 1 1 1 1 1 1 1 Distribution: 1 1 1162Q 1 SC SE FOP RBa M 703 (REPLACES FORM 703 NOV 791 1. Stearn.,.- Page i +'���� SANITARY SEWERS (rata/ ..,, Spec. 5/16/86 A.068 Date r ` 5/16/86 1 1 t TABLE OF CONTENTS SECTION PAGE 1 1.0 SCOPE 1 2.0 REFERENCES AND STANDARDS 1 3.0 MATERIALS 2 4.0 INSPECTION OF MATERIALS AND TESTING 3 1 5.0 HANDLING AND STORAGE OF MATERIALS 3 6.0 INSTALLATION 3 7.0 LAMPING 4 8.0 CLEANUP 4 1 1 1 1 1 1 1 1 1 FORM 703A 4/84 eaMS. mir Page 1 1 Catal #7.4. SANITARY SEWERS Spec A.068 Date 5 -16 -86 ' 1.0 SCOPE ' 1.1 The work covered by this specification consists of furnishing all plant, labor, equipment, tools and materials needed to install sanitary sewer pipe, septic tank(s) and leach field components to lines and grades shown on the drawings and as called for in these specifications. 1.2 The construction required herein shall include sewers to points ' of connection with the building drains five feet outside the building perimeter. ' 1.3 Excavation and backfilling shall conform to Stearns Catalytic Specification A.061 entitled "Trenching, Backfill and Compaction." ' 1.4 Manholes shall conform to Stearns Catalytic Specification A.067 entitled "Manholes and Inlets." 2.0 REFERENCES AND STANDARDS ' 2.1 The latest edition of the following documents form a part of this specification in their entirety except as modified by this specification. ASTM American Society for Testing and Materials A615 Deformed and Plain Billet -Steel Bars for Concrete Reinforcement C33 Concrete Aggregate 1 C136 Sieve or Screen Analysis of Fine and Coarse Aggregate C150 Portland Cement D2657 Heat - Joining Polyolefin Pipe and Fittings D3261 Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing D3350 Polyethylene Plastics Pipe and Fittings Materials F481 Installation of Thermoplastic Pipe and Corrugated Tubing in Septic Tank Leach Fields ' 1162Q FORM 703A 4 /B4 rr. „° , 4� 7 I Y bl I� Ag 717 M II Imo. 'I+n Alrr YI f . If IAELlick wk $ � Page 2 +,. dl alo 1■:11 SANITARY S WERS Spec A.068 Date 5 -16 -86 ' F714 Polyethylene (PE) Plastic Pipe (SDR -PR) Based on Outside Diameter 1 F810 Smoothwall Polyethylene (PE) Pipe for Use in Drainage and Waste Disposal Absorption Fields t 3.0 MATERIALS ' 3.1 Pipe shall conform to the materials requirements and respective specifications listed below. ' 3.1.1 Sewer pipe shall be high density polyethylene (HDPE) pipe of the size and standard dimension ratio (SDR) shown on the drawings, and shall conform to ASTM Standard Specification F714. 3.1.2 Septic tank leach field pipe shall be smoothwall high density polyethylene (HDPE) pipe and shall conform to ASTM Standard Specification F810. 3.1.2.1 Leach field pipe shall consist of both perforated and non - perforated pipe, as shown on the drawings. (a) Perforated pipe shall have two rows of ' equispaced holes, at the four and eight o'clock positions, on five -inch centers. ' (b) The holes shall be cleanly cut to a nominal diameter of 1/2 -inch. ' (c) The pipe shall be clearly marked at the twelve o'clock position, relative to the holes at the four and eight o'clock positions. ' 3.2 The septic tank(s) shall consist of one or more precast concrete units complete with baffles, cast -outs, access openings, access ' risers, and covers as shown on Drawing 12- 000 -009. 3.2.1 Portland cement shall conform to ASTM C150 and shall produce a minimum strength of 4500 psi. 3.2.2 Fine and coarse aggregates shall conform to ASTM C33. ' 3.2.3 Reinforcing steel shall conform to ASTM A615, Grade 40 or 60. 1 ' 1162Q FORM 703A 4/84 Steams., it Page 3 Cad 4 _„m SANITARY SEWERS Spec A.068 i Date 5 -16 -86 1 3.2.4 Vendor's drawings for the proposed septic tank(s) shall be submitted to the Engineer for approval. ' 3.3 Leach Field Components t 3.3.1 Absorption trench gravel shall consist of clean, sound, graded aggregate ranging in size from 1/2 -inch to 2 -1/2- inches. 4.0 INSPECTION OF MATERIALS AND TESTING ' 4.1 At the discretion of the Engineer, all materials furnished by the Contractor will be subject to inspection at the manufacturer's plant. In addition, all pipe and specified materials are subject to inspection at the point of delivery by the Engineer or through his inspectors. Materials found to be defective due to manufacturer or damage in shipment shall be rejected and removed from the jobsite. 4.2 The Owner or his representative may retain a Testing Agency to perform inspection and testing of the work as installed. 5.0 HANDLING AND STORAGE OF MATERIALS ' 5.1 All materials shall be protected from damage in handling and storage. Wherever the trench line is accessible to the pipe delivery trucks, the pipe shall be strung along the side of the trench in the customary manner. However, in tight spots, it shall be necessary to unload and store the pipe some distance away from the location where it eventually will be laid. Care shall be taken to place the pipe on an area free of sharp objects when the pipe is laid directly on the ground, to avoid scarring or gouging the pipe. If the pipe is stacked for storage, the height of the stack shall not exceed five feet. 1 6.0 INSTALLATION 6.1 All pipe shall be laid to the line and grade shown on the drawings. There shall be a minimum of three (3) batter boards in place and checked for line and grade at any time before laying any pipe. 6.2 The interior of the sewer pipe shall be cleared of all dirt and ' debris as the work progresses. All sewer lines shall be flushed and washed of all remaining dirt and debris. ' 1162Q FORM 703A4/84 Page e 4 Stear 9 Cain jr:i;0 SANITARY SEWERS Spec 5-16-86 Date 5 -16 -86 6.3 Any adjustments required to the line or grade of the pipe shall be done by either scraping away the soil or filling in with ' adequate granular materials and tamping them firmly under the body of the pipe. No blocking or wedging of the pipe will be permitted. 6.4 Where "stubs" are installed, the open end of the stub shall be fitted with a plug or a bulkhead properly placed to prevent any debris or backfill from entering the pipe. 1 6.5 Joining of the high density polyethylene line pipe shall be by the thermal butt fusion method in accordance with ASTM D2657. 1 6.5.1 The joining machine shall be supplied by the pipe vendor. 6.5.2 The Contractor shall follow the pipe vendor's 111 recommendations for joining the pipe. 6.6 Trenches shall be kept free of water and as dry as possible ' during bedding, laying, and jointing and for as long a period as required. When work is not in progress, open ends of pipe and fittings shall be satisfactorily closed so that no trench water ' or other material will enter the pipe or fittings. 6.7 As soon as possible after the pipe is placed in the trench, sufficient backfill material shall be placed along the pipe to 1 prevent pipe movement off line or grade. 6.8 The Contractor shall install the septic tank(s) to the lines and ' grades shown on the drawings, in conformance with the septic tank vendor's recommendations. 7.0 CAMPING 7.1 Completed sections of sewer shall be examined by "lamping" between manholes. Lamping shall be done by the Engineer or his inspector with suitable assistance from the Contractor. 8.0 CLEANUP 8.1 Cleanup shall be a continuous process throughout the duration of the project and no debris, waste or rejected materials will be allowed to accumulate on the premises. 1 1 ' 1162Q FORM 703A 4/84