HomeMy WebLinkAbout01517 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT • 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 Phone (303) 945 -8212 This does not constitute INDIVIDUAL SEWAGE DISPOSAL PERMIT Ns! 1517 a building or use permit. Owner Stevens Construction System Location 3726 C. R. 214, Silt. CO Licensed Installer .__ Conditional Construction approval is hereby granted for a 1 ' Ono gallon ll. Septic Tank or _ Aerated treatment unit, Absorption area (or dispersal area) computed as follows: Perc rate of one inch in /Zr _ minutes requires p a minimum of 2.4 q, sq. ft. of absorption area per bedroom. Therefore the no. of bedrooms 3 x ,2 4 r!_ sq. ft. minimum requirement = a total of / o 4 rsq. ft. of absorption area. May we suggest: / n� p / �x 3 ' d ee p o / B'C4 Z'.K 3 'c� eep. Date.. _ 9 / n 9 ( p . Inspector ,./.1 _ i/ _ — A FINAL APPROVAL OF SYSTEM: t No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system . •proved prior to cover• ing any part. (24< _ Septic Tank access for inspection and cleaning within 12" of ground surface or aerated access ports above ground <,� /�� surface. � \ Proper materials and assembly. -' o seti tank aerated Trade name of septic an or aerate treatment unit. � ' �U / ?F_ _ L /!J ';_ +y -, a f t t ., <.., ,J,! f - y , / I r I r 1 Adequate absorption (or dispersal) area. r e• /r • ! !, - / ! -C. • / ?C Adequate compliance with permit requirements. ' ' _ Adequate cornpliance with County and State regulations /requirements. - - -- Other + / Date _ / L L " 4 � _ Inspector �` /�'� �' RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE /- *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements, Connection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system In a manner which Involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 8 months in Jail or both.). Applicant: Green Copy Department: Pink Copy INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION Approval by OIJNER ” eo,.,s County Official: ADDRESS (3toP - CO-A.19t21,4644 � Coto PHONE f (9/19_ CONTRACTOR_ j fl j j fr.... ADDRESS kS31 3 - CA/l�gyVAq(S , P ,ai__PHONE 1 )G ? —.W/"79 PERMIT REQUEST FOR: (l<New Installation ( ) Alteration ( ) Repair Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes. (See page 4.) LOCATION OF PROPOSED FACILITY: County /ace-ft/ca Near what City of Town /i 'm / Lot Size p p e Legal Description * 1)-b — )Jq , / WASTES TYPE: ( 'fDwelling ( ) Transient Use ( ) Commercial or Institutional ( ) Non- domestic Wastes ( ) Other - Describe 'BUILDING OR SERVICE TYPE: Number of bedrooms 3 Number of persons (Garbage grinder (Automatic washer ('<Dishwasher SOURCE AND TYPE OF WATER SUPPLY: ( 44 well ( ) spring ( ) stream or creek Give depth of all wells within 180 feet of system: A/Dnv t. If supplied by community water, give name or supplier: GROUND CONDITIONS: Depth to bedrock: Depth to first Ground Water Table: Percent ground slope: S `" DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: 0 /Jj ,' Was an effort made to connect to community system? /Yd TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( Tank ( ) Aeration Plant ( ) Vault ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, potable use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, other use ( ) Chemical Toilet ( ) Other - Describe: FINAL DISPOSAL BY: ) ( P Absorption Trench, Bed or Pit ( ) Evapotranspiration ( ) Underground Dispersal ( ) Sand Filter ( ) Above Ground Dispersal ( ) Wastewater Pond ( ) Other - Describe: WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? Page 2 SOIL PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer.) Minutes per inch in hole No. 1 Minutes per inch in hole No. 3 Minutes per inch in hole No. 2 Minutes per inch in hole No. Nanie, address and telephone of RPE who made soil absorption tests: Name, address and telephone of RPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposes of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations adopted under Article 10, Title 25, C.R.S. 1973, as amended. The undersigned hereby certifies that all statements made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further under- stand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for per- jury as provided by law. Date ps n Signed ( ,Er ,;p PLEASE DRAW AND ACCURATE MAP TO YOUR PROPERTY Page 3 PLOT PLAN AND DESIGN FEATURES: Include by measured distance location of wells, springs, potable water supply lines, cisterns, buildings, property lines, subsoil drains, lake, water course, stream, dry gulch and show location of proposed system by direction and distance from dwelling or other fixed reference object, and additional submissions in support of this application such as data, plans, specifications, statements and commitments. I 1 • 1 I Q 11 a3t Page 4 turkAv. S �w • r rrt_ us JrJitli 10 tit UUNSIRUGItU (11/2" to 213" Clean Gravel Required Unless Otherwise Approved) TOP TOP 4" o00 •po° • 7+T Length deter- Perforated $pOov° 00 o °$• o0o v Gravel mined from ,,ii. :� p �0 0 0 0 0 ° o ° 000 0 0 0 oa pert test Iloo vo0 results ^ ,.� _ ®`4" solid pipe 00 from tank 4 solid pipe ex• ,.,, ^ ��E * tending into , ,� .� drywell 1' doors 1 1 b 0 0001) •∎ i•• • 4 hay or 3 } 040 OO Opp ° O O �q pew Oa p t o ° ° c , o ••;••i• straw over rocl • I D 00 C O O 0 6 .8 °p p p� • � �• • � • t . �i�: • • O O�q GG eA W O O G � o o OQ p ! ■* __ _ 3' l 6' 1 3' *Size determined from perc test results r SIDE VIEW Backfill SIDE VIEW Cone Ba2kfi11 o x���X ^ x���x 4" a Backfill j x ^ or straw 4" solid pipe to tar Impl a°8$ e9, -•f: " , ravel over kip 4" hay or straw O- J. 4" 'gg�� c 0O `1 4 'ravel n ►`r . 1 ' _0000 °0 „ 'ravel y a�, : Gravel. ,-; SI . . . • %., 0 9 00 0 , o 6 " Gravel ^ , , � -- e• uk. P o, pipe under i * `•� Concrete rings or ° � 6 o P P • • $ cinder blocks P • 1' of gravel in n Seepage Bed ' bottom � � Drywel1 n n Other (FOR APPI Tr.ANTC TNFORMATTON\ PERCOLATION TESTS The successful operation of your septic system depends on the rate the soil in which your leach field will be installed will accept water. This is critical. The rate of absorption is called the percolation rate and it determines the size of the leach field needed for a particular flow of sewage and in some cases even determines the feasibility of the installation of a septic tank and leach field system. AN EIGHT (8) FOOT PROFILE HOLE IN THE LEACH FIELD AREA IS REQUIRED IN THE STATE OF COLORADO TO DETERMINE THE PROX- IMITY OF GROUND WATER AND BEDROCK. In some cases the profile hole may be waived but only by specific approval of the Environmental Health Department. PERCOLATION TESTS MUST BE DONE AT THE GROUND DEPTH WHERE ABSORPTION WILL TAKE PLACE. STANDARD SEEPAGE BEDS (LEACH FIELDS) ARE INSTALLED THREE FEET DEEP, SO THE PERCOLATION HOLES ARE DUG FOUR FEET DEEP, AT LEAST 20 FEET APART; THE PERCOLATION TEST I5 DONE IN THE BOTTOM ONE (1) FOOT OF THE HOLE. • 8 " -12" Ground I i Level I i I I 8 " -12• 4, 1 I I I , I � Post Hole i 1 Back Hoe Hole L - -J A post hole digger, auger, or back hoe can be used to dig the percolation test holes. If a back hoe is used, dig the back hoe hole 3 feet deep and put a test hole 1 foot deep and 8 to 12 inches in diameter in the bottom. Installation of absorption areas (i.e. drywells) deeper than three feet requires the permission of the Environmental Health Department. Saturation with water will affect the percolation rate, and since the system will be expected to operate when the soil is saturated with water, THE HOLES MUST BE FILLED — WITH WATER AT LEAST 8 HOURS BEFORE THE TEST, AND ALLOWED TO STAND. More water will need to be used to perform the percolation test, so AT LEAST 10 GALLONS OF WATER SHOULD BE ON HAND WHEN THE TEST IS PERFORMED. ( FOR APPLICANTS INFORMATION) Page 6 PERCOLATION TESTS FOR DRY WELLS (SEEPAGE PITS) ARE PERFORMED AT THE LEVEL OF THE BOTTOM OF THE PIT (USUALLY 10 FEET). Ground Level 10' 8 " -12" 1 1' I Percolation Test for Seepage Pit i r_ _ If you call for a percolation test or inspection and for some reason are not ready when the time comes, please call us between 8 and 9 a.m. at 945 -2339 or 625 -3321 to cancel the appointment. THANK YOU FOR YOUR COOPERATION. (FOR APPLICANTS INFORMATION) RECOMMENDED t•IINIMUM REQUIREMENTS FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEMS Before construction is started, the Inspector must be contacted for approval and detailed information concerning the proposed disposal system. Higher standards than those which follow may be required in individual cases to assure attainment of the objectives. (hose objectives are to locate, construct, and maintain individual sewage disposal systems in such a manner that existing or contemplated water supplies will not become contaminated and so that sewage will not overflow the ground surface and result in a nuisance or health hazard. 1. LIQUID CAPACITY OF TANK (GALLONS) (Provides for use of garbage grinder, automatic clothes washers, and other water using household appliances.) Recommended Minimum Number of Bedrooms Tank Capacity 2 or less 750 gallons 3 or less 1,000 gallons 4 1,250 gallons 1 for each additional bedroom add 250 gallons 2. MINIMUM LEACHING AREA OF DISPOSAL FIELD ABSORPTION AREA REQUIREMENTS FOR INDIVIDUAL RESIDENCES Percolation Rate Required Absorption Percolation Rate Required Absorption (time required for Area, in sq. ft., (time required for Area, in sq. ft., water to fall one per bedroom water to fall one per bedroom inch - in minutes) (b) standard trench inch - in minutes) (b) standard trench (c) seepage beds & (c) seepage beds & (d) seepage pits (d) seepage pits *1 or less . . . 10 . . . . 228 *2 15 *3 279 *4 45 (e) 483 5 161 60 (e),(f) 558 *(See Below) *Percolation rates faster than 5 minutes per inch or slower than 60 minutes per inch require engineered systems and/ or Board of Health approval. (a) It is desirable to provide sufficient land area for entire new absorption system if needed in future. (b) In every case, sufficient land area should be provided for the number of bed- rooms (minimum of 2) that can be reasonably anticipated, including the unfinished space available for conversion as additional bedrooms. (c) Absorption area is figured as trench - bottom area and includes a statistical allowance for vertical side wall area. (FOR APPLICANTS INFORMATION) (d) Absorption area for seepage pits is figured as effective side wall area beneath the inlet. (e) Unsuitable for seepage pits if over thirty. (f) Unsuitable for absorption systems if over sixty. Dwelling on less than two acres, areas of high water tables, or areas with a percolation test rate faster than 1" in 5 minutes must have alternative sewage facilities, i.e., central collection, holding tanks, individual treatment, etc. EXCEPTION: Absorption areas may be allowed with percolation rates faster than one (1) inch in 5 minutes provided the soil is a sandy texture and no water table problems art encnurlteryj. 1. Maximum length of drainage line: 2. Minimum width of drainage trench: 100 inches linear feet 18 3. Minimum spacing between trenches or pipes: 6 feet 4. Maximum grade of drainage lines: 5. Minimum depth rock under drain PVC: 6 " u n d er as possible 6. 6. Minimum depth of cover over distribution lines: 12 inchesPVC, 2" over PVC 7. Maximum depth of cover over distribution lines: Variable 8. Minimum grade of house sewer: 1/8 to 1/4" 9. Minimum distance of sewage disposal system per linear ft. from dwelling: 10 feet 10. Minimum distance of leaching area to a well: 100 feet 11. Minimum distance of septic tank to a well: 50 feet 12. Minimum distance of leaching area to a stream of water course: 50 feet 13. Minimum distance from septic tank and disposal field to property lines: 25 feet for drywell; 14. Minimum sewer pipe and distribution 10 feet for leach field Pipe: 4 inch diameter Septic construction should be of concrete, concrete block or of a material that will resist deterioration and which can be made reasonably watertight. Acceptable drain field pipe materials include plastic, terra cotta, concrete. If the house sewerline is longer than 10 feet between house and septic tank, a clean -out Y should be installed as near as practicable to the house. Septic tanks should be inspected once a year and cleaned when necessary. Cleaning is recommended when space between the scum accumulation and sludge residue on the tank bottom is less than 18 inches. The Department recommends pumping a septic tank once every 4 years when a yearly inspection by the owner is not practical. (FOR APPLICANTS INFORMATION) Page 9