HomeMy WebLinkAbout02556 GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit 2556 109 6th Street Suite 903 Assessor's Parcel No. Glenwood Springs, Colorado 81601 Phone (303) 945-8212 This does not constitute INDIVIDUAL SEWAGE DISPOSAL PERMIT a building or use permit. PROPERTY Owner's Name Chuck McCurry Present Address 0404 Pinon Drive, G.S. Phone 928 -0678 System Location 0206 Cedar Cove, Los Amigos. Lot 20. Gleennwod Springs Legal Description of Assessor's Parcel No. ,f SYSTEM DESIGN Septic Tank Capacity (gallon) Other Percolation Rate (minutes /inch) Number of Bedrooms (or other) 3 E 6 t /✓ilk reedy,- Required Absorption Area - See Attached Special Setback Requirements: Date - Inspector - FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer k ary Exe.i9A Septic Tank Capacity 2000 64t -P44.ST/G - B4FGLG'D • Septic Tank Manufacturer or Trade Name . /yORWES GO Septic Tank Access within 8" of surface yes Absorption Area 3 r+ � .//✓ in/ .? A7rJ2 �4J / ea 0/l,r,epX Absorption Area Type and /or Manufacturer or Trade Name /A0`7, T2Aic--yr` Adequate compliance with County and State regulations/requirements J/.`5 Other 6a TD COW GQ Date 3 -&' Inspector %/ P RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit Is valid only for connection to structures which have fully complied with County zoning and building requirements. Cpn- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual seWage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine — 6 months in Jail or both). White - APPLICANT Yellow - DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER ('buck rnc. t ids ADDRESS O ).OG Cea.a Cove - G ( --- 11 - PHONE ?2b - oG CONTRACTOR Fre' Consf me �.nes fr ADDRESS �S T&, J e t ,. fk PHONE 9Y5" - s /9 PERMIT REQUEST FOR (L'NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY; COUNTY 6J0.rPVCIr9. Near what City or Town 'e n Size of I,ot Legal Description or Address ©106 CejQe4 r Wove G T WASTES TYPE: (t DWELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON - DOMESTIC WASTES ( ) OTHER - DESCRIBE BUILDING OR SERVICE TYPE: P/w t t: - FAM i ty Number of Bedrooms 3 Number of Persons a (k) Garbage Grinder (t-) Automatic Washer ( •-)- Dishwasher SOURCE AND TYPE OF WATER SUPPLY: ( ) WELL ( ) SPRING ( ) STREAM OR CREEK Give depth of all wells within 180 feet of system: If supplied by Community Water, give name ofsupplier 1-o% Pl rn ;S„t Banco S'V.bri• GROUND CONDITIONS Depth to bedrock: J f o '7 _ Depth to first Ground Water Table N Percent Ground Sloped DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: severe) too Was an effort made to connect to community system? ( ) YES (✓f NO TYPE OF INDIVIDUAL SEWAGE DISPOSAL. SYSTEM PROPOSED: ( v(SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET ( ) OTHER - DESCRIBE FINAL DISPOSAL BY: ( ) ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION (1)' UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER- DESCRIBE in fill fcci ors WILL EFFLUENT BE DISCIIARGED DIRECTLY INTO WATERS OF THE STATE? no 2 • PERCOLATION TEST RESUL'T'S; ('1'o be completed by Registered Professional Engineer) Minutes /5 per inch in hole No. I Minutes 40 per inch in hole No. 3 Minutes 3o per inch in hole No. 2 Minutes per inch in hole No. Name, address and telephone of RPE who made soil absorption tests: 1d - P (,'eo-f ec Nance, address and telephone of RPE responsible for design of the system: rfnar -(ec - Pele lie Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health deparuueut for proposes of the evaluation (tithe application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations adopted under Article 10, Title 25, C.R.S. 1973, as amended. The undersigned hereby certifies that all statements made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal action for perjury as provided by law. Signed r`2 Date 2 -70- SC PLEASE DRAW AN ACCURATE MAI' TO YOUR PROPERTY!! c Pc L'P y . rr' E-- Los fni'SO4 j2l. /P Vz) 9-p 3 • ENARTECH Inc. Consulting Engineers and Hydrologists February 20, 1996 Mr. Jim Frey Frey Construction 85 Tanager Drive —• sec sKLr4e &ace Glenwood Springs, CO 81601 ����`�� m'` 7 - RE: ISDS for Lot 20, Los Amigos Ranch /X4 bt Dear Jim: This letter is to provide the recommended design of the individual sewage disposal system for Lot 20 of Los Amigos Ranch Subdivision No. 2 in Garfield County. Soil percolation testing performed by Hepworth - Pawlak Geotechnical, Inc. indicated on -site percolation rates from 15 to 60 minutes /inch with an average percolation rate o 35 inutes /inch. A soil profile pit indicated subsoils of gravel, cobble and boulder -size basalt rock in a silty sand matrix. Practical refusal to - digging was encountered at 6.5 feet, probably on basalt rock. Hepworth- Pawlak's report indicates that the site should be suitable for a conventional infiltration sewage disposal system, and that a mounded system will probably be needed due to apparent shallow basalt rock. I recommend the installation of a conventional septic tank and leachfield • system with 29 "Infiltrator" leachfield chambers in trenches. The design of the leachfield is based upon a soil percolation rate of 60 minutes per inch; a copy of the design calculations is attached. A percolation rate of 60 minutes per inch rather than the average rate of 35 minutes per inch has been used to allow for the presence of rock in the subsoil beneath the leachfield chambers. Additional requirements include a maximum trench depth of 2.5 feet to allow a minimum of 4 feet between the bottom of the leachfield and the potential bedrock depth of 6.5 feet, and a requirement to notify the system design engineer in the event that bedrock is encountered within any trench excavation. The sewage disposal system should be installed in accordance with the attached Construction Specifications. If you have any questions, please give me a call. Sincerely, 1181.1` ENARTECH, c. s r � ti ilJ • 6 i2t • • • : Peter elau, �:�•sa PB /jlw rt Enclosure cc: Steve Pawlak P393-06 (P393 0IA)96 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs. Colorado 81602 (970) 945 -2236 Fax (970) 945 -2977 • • � y +S` 0 4 �, © /S� i t sNc- CONSTRUCTION SPECIFICATIONS . -j INDIVIDUAL SEWAGE DISPOSAL SYSTE AgiB 1 0. LOT 20, LOS AMIGOS RANCH 6 -4; ENARTECH, INC. 2/20/96 > 4 • t ` , a (• c D 1. The sewage disposal system shall consist of a minimum 1,000- gallon septic tank, a distribution box, 29 standard "Infiltrator" chambers in trenches, and appurtenant piping. 2. The maximum depth of the bottom of the trenches for the leachfield chambers shall be 2.5 feet below natural grade. The minimum depth of the bottom of the trenches shall be 1.0 feet below natural grade. 3. Rocks shall be removed from the bottom of leachfield trenches and filled with loose soil. Rake the bottom of the trenches level with a rough surface prior to installation of the chambers. Gravel (1" screened) may be used as a leveling course. 4. Notify the system design engineer in the event that bedrock is encountered within any trench excavation. • 5. Provide a minimum of 6 feet of separation between each leachfield trench. 6. Install a 4 -inch PVC access pipe in the inlet end of each run of leachfield chambers. Cap the end and paint the above = ground portion of each access pipe black. 7. Construction shall conform to Garfield County sewage disposal system regulations. 8. The system installation contractor shall have prior experience installing disposal systems. 9. The Garfield County building department shall be notified of the construction progress so the system may be inspected. Do not backfill over the leachfield until the system has been inspected. 10. The septic tank and distribution box shall be bedded and installed level in accordance with the manufacturer's recommendation to prevent settlement. 11. All piping shall be 4 -inch PVC sewer pipe at a minimum 1/4 -inch per foot slope, shall be bedded and backfilled with 3/4" gravel or select native soil with rocks removed. Compact all backfill. Piping shall be installed watertight and to prevent freezing. 12. Infiltrator chambers shall be installed in accordance with the manufacturer's recommendations (copy attached). 13. Each trench of leachfield chambers shall be level; the trenches may "step down" the slope, with each trench bottom at a different elevation. 14. Standard "Biodiffuser" leachfield chambers may be substituted for the "Infiltrator" chambers. JOB J .y (, : ENARTECH, INC. • 302 Eighth Street, Suite 325 SHEET NO. 1 OF P.O. Drawer 160 CALCULATED BY Po RFt ft() DATE a / r�i CV!E) GLENWOOD SPRINGS, CO 81602 (303) 945.2236 CHECKED BY DATE SCALE SYSi EH D v iJ CPtLCUUATIONS lN°IVIt4Pub S£wACre S'(ST fr1 r_ or 90 r COS RM"it 605 12f}htcrf SU{3. I) 9 esiSv, F low = C3 bedrock -, Nc (2- I oaisov , s/br)X(7s 9 pcci)K I .S 675 q00t a) Rve-ra Et Ir.( Sv ) fercv lwk- ;e- . Roe = - 35 wt: 641.4.4 es 7 crc, 3) 0c ;cJv� Perco( & ;ofr. Ra e = bCU wc, -e4 /; NC►k 41)Ca.lcv-lc"ert So; l A sorp *;or (*r _` &o /S = 1, s3, - F +. 5) F. Nuw,yar- of (eac,hf ;e CIAO -6 10 o,-5 _(I �l ,T'"t) 4 O,S ( es 5Y, -J', per Gina-tin bar) = 0 CO) Regwireo2 r1.,,; ., Se Ste = ), 000 5cA..110145 ta,, THE 1 0 2 iiii s i;iat.i :T ..? SEPTIC SYSTEM INSTALLATION X l+r - • .} . 1 • t ic+ a [} _ x • .62 _ _ M. Y� .) «.yam 1, °' ,� - `wc_. • 1i _z ` ` *Apr? ._,.....,,...........„ r ■ ,,, , , ' INFILTRATOR" Is a trademark of Infiltrator Systems, Inc. PAT. NO. 4,759,661 Canadian and other Patents Pending. r ' ( j F L_. Place first unit in the inlet end of trench with • interlocks downstream. • LT " ., )' / , Excavate and level 3' wide trenches. v ' �� a 4 f -e ' rf' �` -. • '4L-L Prepare trench bottom and sides in accordance �� `x " � \ on with state and local regulations. (Infiltrator Systems stems V r � t recommends raking sidewall and bottom infiltrative / \. z -' ` surfaces to eliminate smearing.) >' ' 1 . / ' R. fir;, 1 • '�� f v t • r �'B� • t °. Run distribution pipe through inlet opening in end J a ` ;. plate but not beyond splash plate. Single screw may be used • • •' ..a to hold in place. Pipe does not normally run the length of system. t I ' 9 ... l . 1, , ) , t r - - 0 •Y � L a � Y.lY r _. w , �•' w... a ll . . r_' ° a t _ <' " � 4 ? Stip INFILTRATOR" units together, fully engaging interlocks to form desired trench length. Screw splash plate on bottom of open end plate s Y a. " " in notched area, so that splash plate will extend into the 4 � "_ ' y INFILTRATOR'" chomber.. # �� 4. NOTE: 'End plates are stepped to fit in either end of trench. .., Upper step fits Into Inlet end and lower step In downstream end. (with Interlocks) 0, "A cordless drill and self drilling screws work well for '' d ` 1 • • all connections. •Y `;'(,•., t, � _ t y •- • ,• • 0 ! K ' ` - -. `�; y i r,• h °` y a. To keep joints from coming apart during construction • . • and for maximum strength — joints may be screwed .. together with 4 self drilling screws as shown. • ti b. Trench grade can be checked with a level or surveying . . ._ 4 .•' . _ - a. equipment. l ;R"; Screw open end plate Into inlet end (without . interlocks) of first INFILTRATOR" chamber with splash plate / extending Into unit. 6.0.-. ` 9 " . -.it . ., ii I ` ti lly � , .. _ - _ t i S a ,r w Y ." it -..l As= f ( 1 o r } _ .i s -s' •; 2x5' ' -' '' • %?i :,, /. /, ... Screw closed end plate in downstream end of last - ; unit to hold in place. NOTE: For serial distribution, or to loop •. 4 1. z _ , _ _ __.__ . _ _ .i the trenches together, use an open end plate at the downstream end of the trench, and run a pipe from the opening to the next trench. = Excavate and level desired bed area. Rake e. 'r .. z "' , infiltrative surface to eliminate smearing. A L ' I t .. i:3 Place rows of INFILTRATOR'" chambers next 10 each s• other to achieve desired bed area. a. End plates are screwed in place and units are ,... . „/ 1 i - . interlocked as in trench system. (See above) dt' • , ! b. Run distribution pipe to each row of units. Downstream /' ends of INFILTRATOR'" chambers may be looped together, 1 � , -- Fill side wall area to top of slots with native soil. /�t % _ �� \ t "Walk" fill into place to give proper support of sides ' ,.•.� ,/�� w THIS IS VERY IMPORTANT TO ACHIEVE FULL STRENGTH. J / y` a l r} l° P , It a N „ F till Fill side wall area around perimeter and between "! L / ', ,4 ti , ..I rows of units with native material up to the top of slots and • 7 ,. r Th , ., ;a , ".• "walk" in place to give proper support to sides. A, , t ■ Y, f '-+T -1 , - yf . ; Backfill to a minimum of 12" of compacted. r 1, S •� ° x s' )$ ` settled cover for H -10 units and 18" for H -20 units. Avoid :a � large rocks in backfill material. For a large bed that cannot b • be filled from the sides, use a light tracked vehicle and be nil'^ sure to maintain the proper minimum of compacted cover beneath tracks at all times. DO NOT USE WHEELED VEHICLES Backfill to a minimum of 12" of cover after ON THE BED DURING CONSTI UCTION. compaction and settling for H -10 units and 18" for H -20 units Avoid large rocks In the backflll material. "' Avoid vehicle traffic on system during t '�` 'JAL construction since soil has not settled. This is particularly 1 : _ important In sand, since loose sand offers very little • structural support. Most states advise avoiding vehicle traffic to prevent compaction of the Infiltrative surface. K' _. + �T� , II (After proper depth of cover is compacted and settled, +'s+cv .. ; INFILTRATOR" leaching chambers will then support vehicle • -1 ' . ' IY r ` I weight not to exceed 16,000 lbs. per axle for H-10 units and 0 • 32000 lbs. per axle for H -20 units.) - 1 I ' .:4^ la ` - L • } ice 4 ". �' ,�, <\ _ J" r '�. - �. "ma a ot � x i".. Z,{_, • �..). f " ' ice' , .:'I� / 1 � �_ l tt& • R I t ice . . t ✓, Z .y ••• •ei� °.l.F L-'' f and > �" . l 1 F proper depth of cover is 0 dH-20loads • , • �yf c settled, INNFILTLT RATOR'" units will support H-10 a.. #. _' `:. - _ as marked. INFILTRATOR" chambers work exceptionally well in fill or INFILTRATOR" chambers are easilyodapted to pressure mound systems in either a bed or trench configuration. distribution. Simply suspend a predrilled pressure pipe in the 1. Place and prepare fill material as specified by state • top of the units with simple, fool proof plastic pipe straps. and local regulations and system designer. Fill material Supplemental installation instructions, with complete must be capable of supporting H -10 or H -20 loads. details for pressure distribution are available. 2. Install INFILTRATOR'" units according to design in either a bed or trench configuration. • . a. End plates are screwed in place and units are interlocked as in trench and bed systems. . Z' (see above) ^N. 3. Backfill as described for a bed system in item 3 and 4 above using tracked vehicles only. DO NOT USE r " .i ` WHEELED VEHICLES. Infiltrator Systems recommends • "' using a well graded soil for cover above slots to "' maximize load carrying capability. • . • r te „ 1 a.r 1 • I .ate ___. ,. 1 Tr-a , w ATT�� �, ��� �. i �, 2 . ! , . sii. /xa r^z - �� ; :e.,„ � ��.��\ Access port at the top center of each unit may be cut out ° " - . I , - ,. and used for venting, inspection or manifold connection. �- Insert 4" pipe through hole and use a coupling ring as shown to keep the pipe from dropping into the chamber. ,' NOTE: A well graded soil contains an even distribution of C about 10% fines. ranging from silt through sand to - r. .;!• gravel. �..` > -, ' :�. „ uMn Tw+ FOwACTV ° (0) the slruCIUrol inlegnlyd each INF:LIRAIOR' unit. when installed in accordance w' in ndnuloc- ture.s nslruchons if warranted to the original purchaser against defective matenals and J ,,.� • workmanship to re O Veal from dole of manufacture Should o d pd detect aea the j r within waIrOntV DenO0. WrChOSoI must INGOT) InLOralo Systems. Inc d the agent win n fifteen (15) 'j 000 ITINItala Systems ,...m1 $ucdy 0 replacement unit Inulirata Systems Tao. A toecsca ' -O e.c uOes the cost of 'tornado- and/or installation of the units _ +1 (b) THE WARRANTY IN SUBPARAGRAPH (a) 15 EXCLUSIVE MERE PRE NO OTHER WARRAMIES MN ' ^ f RESPECT 10 THE UN115. INCLUDING NO WARRANTIES OF MERCHANTABILITY OR of FITNESS FOR A ,a PARTICULAR PURPOSE THE WARRANTY DOES NOT EXTEND TO INCIDENTAL CONSEOuEN1LAL SPE- ,1+.. ' CALL OR INDIRECT DAMAGES THE COMPANY SHALL NOT BE LABLE FOR PENALTIES OR LIQUIDATED 4 DAMAGES INCLUDING LOSS OF PRODUCTION AND PROFITS LIBOR AND MAIERIAS OVERHEAD a 44 CO515 OR OTHER LOSS OR EXPENSE INCURRED BY &NEP SPECIFICALLY EXCLUDED FROM WAR- RANTY COVERAGE ME DAMAGE TO ME MI5 DUE TO ORDINARY WEAR AND TEAR. / Ai1ERAl10N IR. , 1' ACCIDENT. MISUSE ABUSE OR NEGLECT 01 THE UNITS. THE UNITS BEING SUBJECTED 10 STRESSES GREATER THAN THOSE PRESCRIBED IN THE INSTALLATION INSTRUCTIONS THE PLACEMENT BY BUYER A } 01 IMPROPER MAMMALS INTO BUYERS SYSTEM, 00 ANY OTHER EVENT NOT CASED BY ME > r COMPANY �' . TS-i > L • $ ;��Sy J s �, IN A'E . • FURTHERMORE. NO EVENT SHALLIHE COMPANY BE RESPONSIBLE FOR ANY LOSSCR DAMAGE 10 - _ l F r 1 Y A.' � s THE &P. THE UNITS OR ANY THIRD PARTY RESULTING FROM OR BUYER SHALL BE SOLELY RESPONSIBLE FOR ENSURING THAT INSTALLATION OF ME SYSTEM IS COMPLETED IN ACCORDANCE won ALL AMICABLE LAWS, CODES. RJLES AND REGULATIONS —._._ _. _. —_— —. -._._- — (c) MANNER MA YEP. CA TO 1�HIS NO WARR CHANGE THIS o ANY PARTY Distributed by OTHER THAN TO ME ORIGINAL 6(140 11 you have special problems or questions call INFILTRATOR SYSTEMS'” or your local distributor. Grand Junction Pipe Basalt Div. Supply INFILTRATOR 303-9274501 8; ; SYSTEMS INC. - -- .. 123 Elm Street Suite 12 Old Saybrook, CT 06475 (203) 388-6639 FAX (203) 388-6810 1989 Inritlralor Systems Inc. SS' # 0390 03/04 '96 03 :56 ID : LAN IERFAX3800 FAX: PAGE 1 ENARTECH Inc. Consulting Engineers and Hydrolopisls FAX TRANSMISSION NOTE uggla DATE: 3/ 91%5 L/ NUMBER OF PAGES (INCLUDING THIS COVER SHEET) T • O: ` Ja � �e ` � r�! em e„,)1 IJd�.... FROM: ►`�.4t.. Siam. IN CASE OF A PROBLEM, CALL: JANET WOLF AT (970) 945 -2236; FAX (970) 945 -2977 If chocked, please call to confirm receipt of documents Original to be mailed ADDITIONAL INSTRUCTIONS /COMMENTS: 302 Roth Street. Sate 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (970) 945 -2236 Fax (970) 9452977 03/04 '96 0357 ID: LAN IERFAX3300 FAX PAGE 2 ENARTECH Inc. Consulting Engineers and Hydrologists March 4, 1996 Mr. Jim Frey Frey Construction 85 Tanager Drive - "°0MII�" • Glenwood Springs, CO 81601 al RE: ISAS for McCurry Residence SRL Lot 20, Los Amigos Ranch Dear Jim: This letter is provide design revisions for the individual sewage disposal system for the McCurry Residence on Lot 20 of Los Amigos Ranch Subdivision No. 2 in Garfield County. The original design was described in my letter to you dated February 20, 1996 and in the Construction Specifications attached to my previous letter. The recommended revisions to the design and Construction Specifications are outlined below: 1. The leachfield should consist of 32 "Infiltrator" leachfield chambers in a bed configuration. This design is based upon a soil percolation rate of 50 minutes per inch: a copy of the revised design calculations is attached. 2. The revised Construction Specifications (dated 3/4/96) are attached. The specifications have been revised to conform with a bcd configuration for the 32 leachfield chambers rather than trenches. The purposed of these design revisions is to allow the leachfield to be installed with a minimum amount of disturbance to existing trees. If you have any questions, please give me a call. Sincerely, ENA.RTECN, I-1' . ••• l b ' et " c? .1 ' - t . 4 "' i ° Peter Belau, ' * /y /96 � ,, ..• PB /jlw:� Enclosure • cc: Garfield County Building Department Steve Pawlnk P393.06 (P393_0311)96 302 Eighth Slrnet. Surge 325 9,0 Drawer 160 Glenwood Springs, Colorado 81602 (970) 945-2236 Fax (970)945 03/04 '96 03 :57 ID :LAN1ERFAX3800 FAX: PAGE 3 CONSTRUCTION SPECIFICATIONS INDIVIDUAL SEWAGE DISPOSAL SYSTEM LOT 20, LOS AMIGOS RANCH ENARTECH, INC. 3/04/96 1. The sewage disposal system shall consist of a minimum 1,000- gallon septic tank, 32 standard "Infiltrator" chambers in a bed, and appurtenant piping. 2. The maximum depth to the bottom of the leachfield chambers shall he 2.5 feet below natural grade. The minimum depth to the bottom of the chambers shall be 1.0 feet below natural grade. 3. Rocks shall be removed from the bottom of leachfield bed and tilled with loose soil. Rake the bottom of the bed level with a rough surface prior to installation of the chambers. Gravel (1" screened) may be used as a leveling course. 4. Notify the system design engineer in the event that bedrock is encountered within any leachfield excavation. 5. Install a 4-inch PVC access pipe in the inlet end of each run of leachfield chambers. Cap the end and paint the above- ground portion of each access pipe black. 6. Construction shall conform to Garfield County sewage disposal system regulations. 7. The system installation contractor shall have prior experience installing disposal systems. 8. The Garfield County building department shall be notified of the construction progress so the system may he inspected. Do not backfill over the leachfield until the system has been inspected. 9. The septic tank and distribution box shall be bedded and installed level in accordance with the manufacturer's recommendation to prevent settlement. 10. All piping shall be 4 -inch PVC sewer pipe at a minimum 1/4 -inch per foot slope. shall be bedded and backfilled with 3/4" gravel or select native soil with rocks removed. Compact all backfill. Piping shall be installed watertight and to prevent freezing. 11. Infiltrator chambers shall be installed in accordance with the tanufacturer's recommendations (copy attached). 12. Standard "Biodiffuser" leachfield chambers may be subs • s !'34tfiltrator" S, • �� ,p chambers. n y :44 i t, r 6 . • • V44/14 .1 03/04 '96 03:58 ID:LANIERFAX3800 FAX: PAGE 4 ENARTECH, INC. '°D J CI 302 Eighth Stre, Sulte 325 SHEET NO. 1 or _.. - O. Draw 1 CALCULATED Sy p gift.. PC) DATE 3/ t /96 GLENWOOD ;SPRINGS, CO 81602 (303) 945.2236 CHECKED Dv DATE SCALE S`r'STE V I D Es (CS -i.1 G f GQLAT/ONS (h( IV I UUA-L- SEwACrE Ots905ft SYST 1 Le Or vO , LOS A 60S ct4 SU'4 NO 1) e 9; j h c' l a (3 bedrooms) v is t oersoY,s/ br V 675 1 b75 elect 2) Av&rz e Fe GA 'o.) fercoIc'S e R _ . 3 ►M;nLA:1cc / rid-% 3) Ocsi Perc o(4, -+;et. RAe- -= 50 1,44',nk4 es /i v+c.If 4)Ca�cwlo�{er.( 50',\ A6sorp`i f\ra , 0075 5015 9 55 s3, -c-I'. 5 ) Rc .....∎ C N tn.W.4ay- of t eaC.Avf a Lk.. b ur s 965- h, +) .1. CO'b S er ckow. be- r) c 3�.cL hers to) Red lai re. ft v6 w,u. -1 5s 1 i.. v.1L S', '2e = ),000 3o ! kov,5 • .tom.' ym,�j' J. S.`. . L e