GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT Permit 2801
109 It\h Street Suite 303 Assessor% Parcel No.
•
Glenwood Springs, Colorado 81601
Phone (303) 945 -8212
This does not constitute
INDIVIDUAL SEWAGE DISPOSAL PERMIT a building or use permit.
PROPERTY
Owner's Name John Traul Present Address 0561 Mel Rey Road. Glenwoodtone 945 -8456
System Location 0008 Springridge Court, Springridge Place. Lot 7. Glenwood Springs
Legal Description of Assessor's Parcel No.
SYSTEM DESIGN
Q SO Septic Tank Capacity (gallon) Other
4 µ rat
— / " 10 Percolation Rate (minutes /inch) Number of Bedrooms (or other) 4
Required Absorption Area - See Attached
Special Setback Requirements:
Da, Inspector
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System Installer
GwtilEi /
Septic Tank Capacity / S U 0
Septic Tank Manufacturer or Trade Name CO P & C A r't 0
Septic Tank Access within 8" of surface Y g 5
I)
Absorption Area S T (L EMCgCS D F Cis — s 8 / CNAdvc5Cit S .Sn r4
Absorption Area Type and /or Manufacturer or Trade Name / /-J r l L 9 r . 4 r o(jt f
Adequate compliance with County and State regulations/requirements 7 \� C
(
Other 1 Ca ) SAN, /AA) - 1 - re f 70 f3C IN VT A cl CO
Date 10^.2 ^ J X4,7 Inspector /'T [ � it t
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE
*CONDITIONS:
1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit Is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained In the application of permit commits a Class I, Petty Offense ($510.00 fine — 8
months in jail or both).
White - APPLICANT Yellow - DEPARTMENT
, INDIVIDUAL SEWAGE DISPOSAI. SYSTEM APPLICATION
OWNER . 4 0 (j4/ vt7Z 7 / - �
ADDRESS O S / /29e/ Peoi /2o(, 99,c/. -5 r (o PHONE / + YS 'f� ` /s6
CONTRACTOR cIO#A' /ft Card A— /
ADDRESS ,5 / /fie/ 0 - 7 'd PHONE 9KS
7 /e4r uhsaGi ) Co /a 8 /6 o /
PERMIT REQUEST FOR Pic), NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surroundirig areas, topography of' area,
habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILITY [ �
Near what City of Town 94.venred / C0/0 Size of Lot '* / ia' Legal Description or Address
WASTES TYPE: ( DWELLING ( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON - DOMESTIC WASTES
( ) OTHER - ,DESCRIBE
BUILDING OR SERVICE TYPE: � C..S'/ 1 ewe ✓.-
Number of Bedrooms ? Number of Persons 3
pc) Garbage Grinder 4 Automatic Washer X Dishwasher
SOI JRCE AND TYPE OF WATER SIJPPLY: aQ WELL ( ) SPRING ( ) STREAM OR CREEK
If supplied by Community Water, give name of supplier: Spe-iw y R. I SG .act
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: / 72 -
Was an effort made to connect to the Community Syste ? 4 . /b 241- € 4-1 4- 3
. 'J'
11;n 'i ... 'i 11' . -1i 1 1. _I. 1. S . i' i_l.1' l/ 1/ 1 I
Leach Field to Well: 100 feet -jke. �, � ,/� t, � ,o � 4- o•.- t t' J
Septic Tank to Well: 50 feet �"` '� 4 � ' `
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System to Property Lines: 10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED
WITHOUT A SITE PLAN.
GROUND CONDITIONS:
Depth to first Ground Water Table Ned c -44 ,Q-Ae-1 -e , � Al tho
Percent Ground Slope 6�rmw
2
, .• TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
(N SEPTIC TANK ( ) AERATION PLANT ( ) VAULT
( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE
( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE
( ) CHEMICAL TOILET ( ) OTHER - DESCRIBE
FINAL DISPOSAL BY:
(iii ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION
( ) UNDERGROUND DISPERSAL ( ) SAND FILTER
( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND
( ) OTHER - DESCRIBE
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? 0 0
pF,RCOLATION TEST REST Ill ,TS,;. (To be completed by Registered Professional Engineer, if the Engineer does
the Percolation Test)
Minutes 3 0 per inch in hole No. 1 Minutes .3 ° per inch in hole NO. 3
Minutes a-0 per inch in hole No. 2 Minutes er i ole N e
Name, address and telephone of RPE who made soil absorption tests: X C C. / c - f rt
2.3V l'n . e-C lf.A P , w
/ .-o-v�/ 1&,�
� Go R/6 o/ 9�0 97,5- T 09 _
Name, address and telephone of RP responsible for design of the system: X /LU r� ao 17 t
eo. 6n Z$?-s 1 0)ei[ no I Cirtn R13.9 z-- Ounce aye -05
Fn q40 - fl 7 - 9. 21 9
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the
applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the
permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations
made, information and reports submitted herewith and required to be submitted by the applicant are or will be
represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the
local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further
understand that any falsification or misrepresentation may result in the denial of the application or revocation of any
permit granted based upon said application and in legal action for perjury as provided by law.
Signed #f^✓ �' Date fl7 j, / 179
PLE SE DRAW AN ACCURATE MAP TO YOUR PROPERTY!! l� ) �,n Q
See JAS / 04 C gJ s h ' A ri ai
V
t ,b Pa d-�Mr-pk5A-totle) 9
3
•
)`
KIS K N I S I N E E R I N G I N C I t$ i R.
199'
GARF ELD Lt.
•
September 16, 1997
Mr. Don Owens •
Garfield County Planning •
109 8th Street ,
Glenwood Springs, Colorado 81601
RE: , Revised Individual Sewage Disposal System Design
Lot 7, Springridge Subdivision, Garfield County, Colorado •
• John & Theresa Traul, Owners
Dear Mr. Owens:
•
The purpose of this letter is to provide you with a revision of an individual
sewage disposal system (ISDS) design for the above - referenced property. The
revisions to the original ISDS design, which was presented in m o ou dated •
May 6, •1996, affect only the general layout and the type of graveless leaching chamber
used to construct the soil absorption trenches. The design criteria, such as the
estimated wastewater flowrate and the required soil absorption area, are not affected ,
by this revision. The revised ISDS design presented here conforms to the regulations
set forth in the Colorado Department of Public Health and Environment (CDPHE)
Guidelines on Individual Sewage Disposal Systems (Revised 1994).
Desion Criteria
1
The ISDS for this property has been sized to accommodate the wastewater flow
from a residence . having up to four bedrooms. The calculated design . flow is 720
gallons per day (gpd) and the required soil absorption area is 910 square feet. The
original design of the soil absorption trenches called for two Sets of two 75 -foot
trenches (utilizing standard Infiltrator graveless leaching chambers) connectdd in
series that would be operated as alternating leach fields.
f
The revised absorption trench design utilizes five 50 -foot trenches (utilizing the
new Infiltrator® Equalizer 36 chamber) operated in parallel. The required total length of
the absorption trenches was calculated based on information contained in a letter from
Thomas Bennett, CDPHE ISDS Program Coordinator, to Mr. Jim Bransfield of Infiltrator
Systems, Inc., dated May 17, 1996 (copy attached).
P.O. BOX 2 8 7 5 D U R A N G O , C O 8 1 3 0 2 • 9 7 0- 2 4 7. 0 5 0 0 • FAX-247-4229
f
•
1, •
John & Theresa Traul Lot 7, Springridge Subdivision •
Revised ISDS Design ,
The CRPHE has approved the Infiltrator Equalizer 36 chamber for use in r
Colorado at an equivalency of 31.93 square feet of absorption area per unit when used
in a trench configuration. The required soil absorption area for this ISDS is 910 square ,
feet, which would require a minimum of 29 Infiltrator Equalizer 36 chamber units. I
have revised the design of the absorption area to include a total of.30 Infiltrator
Equalizer 36 chamber units (six units in each of five trenches), which is' equivalent to .
approximately 958 square feet. This revised soil absorption area design should be
adequate to dispbse of the septic,tank effluent at this property. '
Revised ISDS
The revised ISDS will consist of a 1,500 - gallon septic tank, a distribution box
• and five subsurface soil absorption trenches. The materials and methods of
construction are described in myoriginal letter of May 6, 1995 and shown on the r
attached drawings. The revised layout and materials used in the construction of the
soil absorption trenches are shown in the drawing attached to this letter.
Summary -
Kaye revised the design for•an ISDS at the property owned by John and ,
. Theresa Traul, located on Lot 7 of the Springridge subdivision in Garfield'County,
• Colorado. The ISDS design concept, which utilizes.a septic tank for treatment of
domestic . sewage and soil absorption for disposal of the effluent, remains the same as ,
in my original letter to you dated May 6, 1996. The original design assumptions rOmain ,
the same, only the type of graveless chamber and the layout of the soil absorption
trenches have been revised: Please feel free 6 contact me at (970) 247 -0500 if you
have any questions or comments regarding this revised ISDS design.
Sincerely, 4 ,. , i
KIS Engineering, Inc. pp REo /4
lb
s , • •
Michael Hannigan, P.E. ..,,. :n r
• President � E ,
Attachments
cc: John M. Traul
961701 2 September 18, 1997
•
1
ISDS LAyou
40
No Saw.
Res IDRJGE 1
EJI rDOTPRI,JT ? `� \e,\ � J1
, � - 4• Nat Doom* ?VC ?Ire
As w svnw Fox - - --� (sck•40, saR 35 ASTM 3034
SOIL A350RPriorJ
Nbr : EACH SOIL ABSORPTIOn& TKLa.10 TZ', 34CJ1ES
SHAD_ Be CCASTRUCIED WITH A Le.EI.
T EC ' �T�IDM SURFACE k SIX ((.) .•
1NFloweroR® Ecu4L12 g 3(o citimiseR UN at , (MIIJ I MVM)
OesatVkt& fbsr trlc/d..) 50 —"I
PROJECT DAIE
ISDS 1xs SS1 KeVls►onl S" I(D, 1997 y11
DRAWN OE
Lo `, .
K
W1.7 - SpRINI'RIDCoc gvftDIV• IS ENGINEERING INC
G +Ew CcvM'rl, C )
PROJECT No.
OWNC � R .,_11 • � / � + ��{���� - /�T�jy i1 1421101
• \ry 4 1�MREY 1w& L Snger NO. 4 or 1
a STATE OF COLORADO
J .. - Roy Romer, Governor -
Patti Shwayder, Executive Director of o
ti . #
Dedicated to protecting and improving the health and environment of the people of Colorado oZ77 C
4300 Cherry Creek Dr. 5. Laboratory Building • G�� •
Denver, Colorado 80222-1530 4210 E. 11th Avenue .
Phone (303) 692 - 2000 Denver, Colorado 802 20 -3 71 6 /en •
(303) 691-4700 Colorado Department
of Public Health
•
and Environment
May 17, 1996
Mr. Jim Bransfield
District Manager
Infiltrator Systems Inc.
1087 South Downing Street
Denver, CO 80209
Dear Jim:
I have reviewed the literature and your calculations with respect
to the Infiltrator Equalizer 36 chamber. The Equalizer 36 is
hereby approved for use in Colorado in accordance with the
provisions of Section VIII.C. of the Guidelines On Individual
Sewage Disposal Systems.
I concur with your calculations regarding the absorptive area
equivalence for the Equalizer 36 chamber. As per your calculations
the bottom area for each chamber unit is provides 24.99 square feet
of absorptive area in a trench application and 20.8 square feet in
a bed system. Sidewall area would add an additional 6.94 square
feet for a total absorptive area of 31.93 square feet per Equalizer
36 unit in a trench system. No additional credit would be
available for sidewall in bed designs.
Therefore, the Division hereby approves the Equalizer 36 chamber
for use in Colorado at an equivalency of 31.93 square feet unit in
a trench configuration and 20.8 square feet per unit in a bed
configuration. These figures are based on the design
specifications presented in your letter of March 4, 1996. Use and
equivalency approvals are subject to the acceptance of same by
local health agencies.
Sincerely,
,4,..e../
(
Thomas Bennett
ISDS Program Coordinator
xc: Local Health Agencies