HomeMy WebLinkAbout03443 Cory and Tess Wesson October 13, 2000 Page 2 presented on Fig. 3, indicate low to moderate compressibility under conditions of loading and wetting. No free water was observed in the pits at the time of excavation and the soils were slightly moist to moist. Foundation Recommendations: Considering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1,500 psf for support of the proposed residence. The soils tend to compress after wetting and there could be some post - construction foundation settlement. The amount of settlement would depend on the depth and extent of subsurface wetting. Footings should be a minimum width of 18 inches for continuous walls and 2 feet for columns. Loose and disturbed soils encountered at the foundation bearing level within the excavation should be removed and the . footing bearing level extended down to the undisturbed natural soils. The exposed subgrade should be moistened and compacted prior to placing concrete. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 36 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 55 pcf for the on -site soil as backfill. Floor Slabs: The natural on -site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. The soils are compressible when wetted. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of sand and gravel (such as road base) could be placed beneath slabs for subgrade support. This material should consist of minus 2 inch aggregate with less than 50% passing the No. 4 sieve and less than 12% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on -site soils or a suitable imported sand and gravel devoid of vegetation, topsoil and oversized rock. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the residence bas been completed: 1) Inundation of the foundation excavations and underslab areas should be H-P GEOTECH . • Cory and Tess Wesson October 13, 2000 Page 4 construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on -site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Sincerely, HEPWORTH - PAWLAK GEOTEC , .I„;,,‘..1, INC. _ :''o °; • Jordy Z. Adamson Jr., . . 0 29 07 D+ Reviewed by: O sit �9 p�.,, tolplw : #''/ %%% 49 S /ONA�- to A ...„ „. .-j( 1 ""0 , ..............-0- - Daniel E. Hardin, P.E. JZA /tl attachments cc: Demco Construction - Attn: Gary Heisel H -P GEOTECH • Moisture Content = 21.3 percent Dry Density = 100 pcf Sample of: Slightly Sandy Silty Clay From: Pit 1 at 6 Feet K 0 1 No movement a upon A 2 wetting 0.1 1.0 10 100 APPUED PRESSURE — ksf Moisture Content = 17.9 percent Dry Density = 103 pcf Sample of Sandy Silty Clay From: Pit 2 at 3 Feet 0. 1 No movement upon a wetting 2 U 3 0.1 1.0 10 100 APPUED PRESSURE — ksf PAWLA 100 793 I GEOWECHNICAL INC. SWELL — CONSOLIDATION TEST RESULTS I Fig. 3