HomeMy WebLinkAbout4353 N0 04353 GARFIELD COUNTY 4 BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81801 (303) 945-8212 4131 C.R. 103 Carbondale Nature of Work I >u:tiding Perit Use of Building Addition to S /1' Owner - Lenard tans burgh ContYaotor Belk /Overlwlt Construction Inc. Amount of Permit: $ 163.35 Date: October 16, 1991 Permit $99.40 Plan. ( R. Bennett: Clerk White Canary - Office Pink - Applicant Gold - Duplicate /' ✓ / GARFIL'LD COUNTY lI / APPLICATION FOR BUILDING PERMIT �,[ - " ) o PERMIT NUMBER / 3 � p7casc print or type DATE 1 0 — I L-P ( ) I TO BE FILLED OUT BY APPLICAN PLOT PLAN « /3 ADDRESS / 4 1/3 i NOTE: Show easements, property line dimensions, ..a SUDDIVISION all other structures, specify north, and street c< FILING # LOT # BLOCK # name. For odd shaped lots, or if space is a TAX SCHEDULE # _. T __ _ too small, provide separate plot: plan. LEGAL (SEC/TWN/RNG) _ _ # OF BUILDINGS NOW ON PARCEL ..r - �— USE OF' BUILDINGS NOW ON PARCEL :=4 NAME Iennrl i �. -r / W MAILING ADDRESS ' (r �C' S l<7 P y C E' C P -- w p CITY �Cde 66 n./oir _ PHONE RG fl 1 -J ael cf 1 ct' {9 "a .NAME /4ney VAi %ri4 ___.__.�. — / c E ADDRESS x7 3 M� o. .frr CI TY rarbe/�J4 /g._ o P WP NAME AL ; ' 1 E ADDRESS /...,{+X..240 E` ._.....�.__.�._...._.._,_. g CITY ycbr/ u �' �1ONE 227 - ' / LICENSE f CLASS OF WORK _yam NEW ALTERATION ADDITION ge DEMOLISH REPAIR f MOVE T_ MOBILE HOME (make /model) S.F. OF BUILDING 2l5 S.F. OF ?0T f H 02 FLOORS / HEIGHT # OF FAMILY UNITS # OF BEDROOMS I INTENDED USE OF BUILDING GARAGE: SINGLE DPI__ CARPORT: SINGLE BBL FRONT PROPERTY LINE. FIREPLACE DOCUMENTS ATTACKED ,STREET NAME /ROAD NUMBER _ WATER SUPPLY Fk8�57`j4 CHECK IF' CORNER LOT DRIVEWAY PERMIT ,$ -54 -.` DESCRIPTION OF WORK PpINNED SITE PLAN j r _._..._,...._.._._..- .�_... C"� +t .0 7 - t•. e & C I /FC' / / t Foe∎ : ", c. e r � / 4P 2 BUILDING PLANS I� SANITARY SEWER CLEARANCE AT/4- I hereby acknowledge that I have read this ON SITE SEWAGE DISPOSAL PERMIT tEx C 1. ,--..,� application and the above is correct and I OTHER DOCUMENTS (.specify) J afire- to comply with 11 county ordinances are' state laws •eg ,'tiny building construction F 72sb ,r!/v ,yop /r/b� RI � / FOR OFFICE VALUATION � T "- &. 0 0 FLO /D HAZARD _ PERMIT FEE $ oo PLAN CHECK FEE $ &4 CERTIFIED BLDG ELEVATION TOTAL FEE $ SCHOOL IMPACT FEE $4(A SPECIAL CONDITIONS IT DATE PERMIT ISSUED ZONING DISTRICT NHW �P w PROBLEMS WITH PERMIT TYPE OF OCCUPANCY r N TYPE OF CONSTRUCTION 14 ADDT'I'TONAL .INFORMATION NEEDED S.F. OF' BUILDING J-2. 'th, S.R. OF LOT 4 f MAX. HEIGHT •_Ir /7 e ROAD CLASS. CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR SETBACKS FROM PROPERTY LINE: FRONT OR ENGINEER REAR RIGHT LE•T OFF STREET PARKING SPACES REQUIRED �� / pp // APPROVED: ,� ..__,� • G/ '� APPROVED:�� r to -$- APPROVED: DEPARTMEP . +AT: PLANNING DEP T DAT Its L esicett c is-- / 6s - 2 -"S -- 4 7/1.16 : // : //1-- /6 12., 2 Y ti a I: 4C f /5 f /a- { / JSS " _ 7 f ?a k-1,21- 3. "-at 7e w g li Ili I l I, Il i III 111 li 1. I , it i: : I l I.; i -I ii Ii ' I I I it rEi w e V 7 v a S a u R111 " / - W II-, R: W � FIDE= F•ILF{ £X.t92 i &T ° w� r l E r °- - HiELb p(2-11.A : IJ WOOV P & NTE r_ 7 F., p„. -01= b - it -I c I�ITP*u Yo1� 'fv IIJ�{'- t/�`iE — LIroH '' " - INL S =. 'M . 1 £. Ir. y IN r.F.HYei: <;u vrx�n t. u{ c. -:er � - w tL- FnoUNr ExT€ F' IxYUVFi 7 e FR- WJ-t P MKS G. R IIECYyrS<<µ e � NIODIF°IATION -IV z, Cd J -L%H ÷.i.1 :-a '. r_' rrul.{BIG�I W F I`rir Ea -C�- Fl i T C 1 F 1, W i Nit 6a / -y9era ne.r .mI e er! , /' e v fr-.y i'42, 1p' 11--) � g r e ! �� • k fil T FcrF / --- .1'' f5 ✓. d�..r ` 1 , 2 U E+4�.Ee -.1] r Fr E∎AA N e I If � g Lk II F 5 f iri e Ie *:F WI trAFii �� _:., .. F I I Jr �ly 1 F F F L y }' ' WE TIN4,m 1 f 1�Y/ e> t cz..?I -1 I ∎(I Is 1 h°) I 0 ) . . . 4 . Io G - - x_ I Etc I k\ , I . l ip', T t crrP t• ' �f \ ; ,, a ` . ', i, . N 't r T I 1 0 ?A , n' . I t V.1 1 V T 11 I ! t IIeW -T1 .4,'.4,',- . e P 1 J T Lcwl- PL .. I . ey4r G , ) pi FIEVJ WPLIF2 I +d , . ! , i I Fri - N5TAL Fax= ro yWF I1-1Tn s- F4'44 5xl JTl'1h - - 'f' - cc+.li ex: P33J &L6 MD S'(i "ll1'c - (g. rio) CF riFJ-U -BUILT Ar -EMaLf of FI- .4_.t 4 N -Itul• IN dll. (MPS. (el sd!_PII I 'JEW E %1`-arlMJ/a - Zs1k PElI4G, . I 1 I i m oon* l Z V TIS°Ili rI 17Z � „ w ' " ' " - . - Ill I 2 A6 WALL (RE II4E iIJGLSS . 0 ' . W/ R - 14 6/. -• " " -r, :.1-0-16 NEW w/ E%ItT,)� � C x sl -tlµc 1-.E 1 _. .,k. VS- 4 AHUIr Nt.T ) d r A Lcxlf. SLA1/242, W/ -. ! ry ,- r eiIa1C- 1'A'LT'ac (p' +4 ' wi 4x wI•k Wwp u ) _- .c 04 4' C.C."../51„ , t z. n z w!'J/d x r M ,e SCa •ri der H yr ! 1 Ir, =' x 2o" {- "erar.. -c Fer efl.r !, /r.11L. FTC.... t'. C_oFlc. NIAU. WI I \ y e,. rich, f o! -. { I) wI2-*a Z) Born -•{ ..,... .... ra i p7 PERMIT R _ DWHE EO� CATION 42 d/ b ` c -00 CONTRACTOR THE FOLLOWING ITEMS MAY HAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH THE PROVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1908 EDITIONS OF TUE CODES. THESE ITEMS ARE REQUIREMENTS FOR R -3 OCCUPANCIES ONLY (ONE AND TWO FAMILY DWELLINGS) AND ARE NOT ALL INCLUSIVE OF THE CODE REQUIREMENTS, BUT ARE MEANT AS A GUIDE TO SOME OF THE MOST OFTEN ENCOUNTERED QUESTIONS REQUIREMENTS.TIILE APPROVED PLANS RETURNED TO YOU SMALL BE KEPT AT THE C LE UIL¢ING SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRI CODE CONTACT THE COLORADO ELECTRICAL INSPECTOR. THERE SIIALL BE A FINAL INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES WHEN COMPLETED AND READY FOR OCCUPANCY AND USB - UBC SEC. 305 (d)- 6) Concrete for foundations and .Load bearing slabs is required to be 3000 psi in 20 days - UBC Chapter 26. Mortar and grout shall be in accordance with UBC Chapter 24 F. Table 24 -A and 24 -B. O Masonry units, mortar, and grout shall be protected during cold weather in accordance with UBC Sec. 2404 (c). Concrete shall be protected during cold or hot weather in accordance with UBC Sec. 2605 (f) and (g). © Minimum concrete and /or masonry foundation reinforcement requirements are shown on the attachment. (Note: these minimums apply only if a foundation soils investigation is not performed and the soils are assumed to have an expansion index of 20 or less and footing loads less than 2000 lbs /linear foot - UBC Sec. 2904 (a) and (b) and Sec. 2906. 4. Foundation frost protection is 30" from finished grade to top of footing - UBC 2907 (a). 5 Foundations shall extend a min. of 6" above finished grade -• UBC 2907 (d). Provide for the control and drainage of surface water away from the building UBC 2907 (f). 7. Foundation walls enclosing a basement below grade shall be damp - proofed on the exterior with approved materials - UBC Sec. 1707 (d). lb Foundation plates or sills shall be redwood or pressure treated wood (UHC 2516 (c)), and shall be bolted to the foundation with not less than 1/2" dia bolts embedded at least 7" into concrete or masonry, spaced not more than 6 feet apart, min. of 2 bolts per piece and within 12" of each end of piece -- UBC 2907 ( €). 9. Exterior concrete or masonry piers shall extend 8" min. above grade unless the posts or columns which they support are treated or decay resistant wood. Columns and posts located in basements shall be supported by concrete piers or metal pedestals extending 6" min. above earth and 1" min. above floor unless treated or decay resistant wood - UBC Sec. 2516 (c) 4. 10. Manufactured trusses, and manufactured joists and beams (i.e. TSI /Micro- Lams, BCI /Versa -Lams, Glu -Lams, etc.), shall be sized and installed in accordance with the manufacturers requirements. 11. Wood joists or floor beams located closer thaq 18" or wood girders c loser thAa 12" to the ground in crawl spaces shall be treated or decay resistant wood - UBC Sec. 2516 (c) 2. 12. Girders supported by masonry or concrete shall have 1/2" air space at top, sides, and ends unless treated or decay resistant wood - UBC 'Sec. 2516 (c) 5. Ends of beams and girders shall have min. 3" of bearing on masonry or concrete - UBC Sec. 2517 (c). 13. Floor joists under and parallel to bearing partitions shall be doubled UBC 2517 (d) 5. 14. Floor joists require full depth solid blocking and must lap a min. of 3" over bearing supports - UBC 2517 (d) 3. 15. Beams, roof rafters, and ceiling and floor joists shall be supported laterally in accordance with UBC 2506 (h). 16. Columns, posts, beams, and girders shall have positive connections provided to ensure against both uplift and lateral displacement -UBC Sec. 2516 (m). 17. Ends of floor joists shall have 1 1/2" min. bearing on wood or metal and no less than 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2. 18. Notches on the ends of floor joists - max. 1/4 joist depth. Bored holes not within 2" of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located in middle 1/3 span -• UBC Sec. 2517 (d) 3. 19. Floor joists and /or roof rafters are insufficient for the span - UBC Table 25• -V -S -1 and UBC Standards. 20. Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UBC -- Sec. 2305 (d) -dead loads shall be as required in UDC Sec. 2305. 1 21'. Floor live load shall be 40 psf -, UBC Sec.2304 (a) and Table 23 -A -1 - dead loads shall be as required in UBC Sec. 2304. " 22. Basic wind speed shall be 80 mph - UBC Sec. 2311. `73. Headers over wall openings 4' wide or less shall be doubled 2" framing lumber on edge. Over 4' wide the header shall be sized for the span - UBC • Sec. 2517 (g) 5. 24. Rearing walls supporting two floor loads are required to be a min. of 3" x 4 "or 2 "x 6" studs with a max. spacing of 16" on center -UBC Sec. 2517 (g) 1. 25. Wood studs may be cut or notched to a depth not exceeding 25% of width in exterior walls and bearing partitions and not exceeding 40% of width in non- hearing partitions - UBC Sec. 2517 (g) 8. ) I 26. Wood studs may have bored holes no greater in diameter than 40% of stud width, 60% of width of doubled studs (but not more than 2 successive doubled studs). No holes shall be bored nearer than 5/8" to edge of stud - UBC Sec. 2517 (g) 9. 7 Wall bracing required both sides.of each corner and every 25 lineal feet - the braced panel must be a min. of 40" in width perpendicular to studs - UBC Sec. 2517 (g) 3. 4J ) Approximate min. insulation values are R -19 walls, R -25 roofs, and R-ll floors over unheated space _ see plans for more specific requireme is - "Colorado Energy Conservation Standards." R S".6 gel` 5-Ate peh #' e . 29. Foam plastic insulation shall be separated from the building interior, including attics and crawl spaces, in accordance with UBC Sec. 1712. Other insulation (including duct and plenum insulation and coverings per UMC Chapter 10) including facings shall meet the requirements of UBC Sec. 1713. 30. Masonry and atone veneer units (5" max. in thickness) shall have min. size of No. 22 gauge by 1" galv. metal ties or No. 9 gauge galv. wire ties and spaced to support not more than 2 sq. ft. of wall area but not more than 24" on center horizontally. When applied over stud construction, the studs shall be max. of 16" on center. Approved building paper must be applied over the sheathing or studs - UBC Sec. 3006 (d). 31. Ceiling height is required to be 7'6" in all rooms except kitchens, halls, bathrooms, and storage areas which may be 7'0" min. - UBC Sec. 1207 (a). - - - - 32. Min. stairway headroom clearance is 6'8" - UBC Sec. 3306 (p). 33. Min. stairway width is 36" - UBC Sec. 3306 (b) and min. landing dimension in the direction of travel must also be 36" - UBC Sec. 3306 (g). 34. Stairways max. run 9 "; max. rise 8 "; max. variation in rise and run 3/0" - UBC Sec. 3306 (c). 35. Enclosed usable space under interior and exterior stairways shall be protected on the enclosed side as required for one -hour fire - resistive construction - UBC Sec. 3306 (m). Fire stops shall be provided in accordance with UBC Sec. 2516 (f) 2c. 36. Stairway handrails, min. height 34 "; max. height 38 "; handgrip portion shall be not less than 1 1/2" nor more than 2" in x- section dimension. Min. of one handrail required on all stairways with more than three risers. Min. 1 1/2" space required between wall and handrail - UBC Sec. 3306 (j). 37. Guardrails of 36" min. height shall be installed at unenclosed floor openings and open sides of stairways, landings, ramps, decks or porches more than 30" above grade or floor below. Open guardrails shall have a pattern such that a sphere 6" in dia. cannot pass through - UDC Sec. 1711. 38. Under -floor (crawl space) cross ventilation is required equal to 1 sq. ft. for each 150 sq. ft. of under - floor, area - UBC Sec. 2516 (c) 6. 39. Under -floor areas shall be provided with a min. 18" by 24" access opening - UBC Sec. 2516 (c) 2. 30" by 30" min. if mechanical equip. In under -floor area - UMC Sec. 709. 40. All sleeping rooms below the fourth story without a door opening to the exterior shall have at least one operable window that meets the following requirements, MAXIMUM sill height, 44" MINIMUM net clear opening height: 24" (x34 1 /4" = 5.7 sq.ft.) MINIMUM net clear opening width, 20" (x41" ■ 5.7 sq. ft.) This also applies to basement sleeping rooms - UBC Sec. 1204. 41. Glazing in hazardous locations as defined in UBC Sec. 5406 (glazing in doors and adjacent to doorways, and glazing in windows located within 18" vertically of a walking surface) shall be safety glazed or protected. 42. Glass in sloped glazing (more than 15 from the vertical) and skylights shall meet the requirements of UBC Chapter 34. Skylights and roof and wall panels of light- transmitting plastics shall meet the requirements of UBC Chapter 52. 43. provide combustion air for fuel burning equipment per UMC Chapter 6. 44. Pressure relief valves and /or combination pressure /temperature relief valves shall be provided with a drain line to a floor drain with min. 1" air gap or extended to the exterior of the building - UPC Sec. 1007. 45. Domestic dishwashing machines shall not be directly connected to a drain or waste disposer without the use of an approved airgap - UPC Sec. 608 (d): 46. Fuel burning appliances shall not be located in any room used or designed to be used an a sleeping room, bathroom, or closet or any enclosed space opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless listed for such use). 47. Appliances (including space heating and water heating equipment) shall be accessible for repair and removal in accordance with the UMC. 48. LPG fueled appliances shall not be installed in a pit, under- floor $cra space, or basement - UMC Sec. 504 ( €). 49. Appliances located in a garage (or in an enclosure opening Into a garage) shall be locat®d out of the normal path of vehicles or protected from damage. Any portion of the appliance creating a flame, spark or glow shall be installed a min. of 18" above the garage floor - UMC Sec. 508. l 50. Each water closet stool shall be located in a clear space not less than 30" in width and 24" in front of stool - UBC Sec. 511 (a). 51. Toilet rooms without operable windows shall be equipped with an exhaust system ducted to the exterior - UBC Sec. 1205 (c). 52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbent surface to a height of 70" min. above the drain inlet -- UBC Sec. 510 (b). Water resistent gypsum board shall not be used over vapor barriers, in saunas or steam rooms, or on ceilings - UDC Sec. 4712. 53. Attic access opening of not less than 22" by 30" is required - uBC Sec. 3205 (a). 30" by 30" if mechanical equip. in attic space - UMC Sec. 708. 54. Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150 of the area of the space ventilated. The area may be 1/300 if provided equally at lower and upper portions of the space with min. 3' vertical separation of locations - UBC Sec. 3205 (c). 55. Garage side of common wall between living space and garage shall be finished with materials approved for one - hour fire resistive construction. This also applies to ceilings and bearing walls if living space above the garage. Self closing min. 1 3/8" solid door is required between house and garage - UBC 503 (d) 3. 56 Electrically wired, interconnected smoke detectors are required in all sleeping room access areas near the top of stairways in upper levels, and near the bottom of stairways to basements - UBC Sac. 1210 (a). 57. Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UBC Chapter 37. 58. Masonry and concrete fireplaces and barbecues shall meet the requirements of UBC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed as a supporting member - UBC Sec. 3703 (a). 59. 60. COPIES OF THE ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items above or below are available upon request). Excavations, fine, foundations, and retaining walls - UBC Chapters 23 and 29. Retaining walls - UBC Sec. 2308 (b) and 2907 (g) 4. Roof coverings and drainage - UBC Chapter 32 (Roof drains sired in accordance with UPC Appendix 0). Roof sheathing - UBC Sec. 2516 (i). Wood combined with (supporting) masonry or concrete - UBC See. 2515. Floor sheathing - UBC, sec. 2516 (h). Wiring in plenums - UMC Chapter 10 and NEC. Fire and draft stops - UBC Sec. 2516 (f). Nailing requirements for connecting wood members - UBC Sec. 2516 (j). Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish chutes - UBC Sec. 1706. Exterior wall coverings and exterior weather protection -- UBC Sec. 1707 (d) and 2516 (g). Interior application of gypsum wallboard and interior and exterior application of lath and plaster - UBC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. Landings and floor level at doors - UBC Sec. 3304 (i). Cross connection control and back flow prevention - UPC sec. 1002 and 1003. Treated Wood Foundation Systems - UBC Standard 29 -3. :fi C r` 7 r 0.10 /"rSf spH c c 1 1, f, ' a 1 S r — .......) , r, �� /a 0 .1 -_ �__..� - -... ____ r t r* - . --___ 1 fAL pQ7F To TIE- Ir•l{O f rN -:10 1, .1`° -11 " F.- tri.UT IssLS MR -+ 51Z." - Ma_ ({L, b,) t =�e.b - e�UlLT A J ABLY OF FLYNlat; . F.I&rylr It-,st.n, (.1.40. 691'.) SO rFIG1�!ar • 1 era � -a° - - 'r - z - rk pr n'!c0 ! i ur. clsT co Pl ru I ItaVivd! 3 IZ� 12_ L. ' Si ;,, SHEurr a'x- _.� 4 o1J L W/+J.l.5 :. tit, e i 14 4411412 7 C :40 INSPECTION WILL NOTE MADE UNLESS . THIS CARD IS POSTE ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GARFI COUNTY, COLORADO Date IssuedIC jIO' Zoned AreaA X Permit No, - ..+�- - - -- AG EL ENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building Inspector and a EL nd IMMFD!ATY BECOME NULL AND VOID, Use l f ' 1 ' 1 on it r T�1 ¢ Address or Legal Description 1 M , L, -4u— .� _ : I Owner _ gin e.. ._ k 4,14 / . dl` a• 1 ♦ t Setbacks Front Side Side Rear This Card Must Be Posted So It le Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering r Electric -Final (by S' f inspector) Footing 0 7'\ -a 2 ,7icc -3-3 / `]_ S Foundation d.fb< (tc .- 5" Plumbing- Underground Gas Piping Heating Ventilation Frame J fi – `7/ 25T- Insulation 7 / 2 – -q/ Plumbing -Rough Drywall. / r_ k;lectric- Rough (by STATE inspector) rj Final / – y p – ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING – WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVEGROUND. Ar THIS PERMIT IS NOT TRANSFERABLE Phone 945 -8212. 109 8th Street, Courthouse, Glenwood Springs, Colo. APPROVED DO NOT DESTROY ThIIS CARD ^ <ir My 1824 CERTIFICATE OF OCCUPANCY BUILDING DEPARTMENT GARFIELD COUNTY, COLORADO Issued Without Fee January 11. _1991 Permission is hereby granted to Lannarrri T n.ah,trYj, Building Permit No, 43SY. Zone District situated at 4111 C. LL 10'1 Carbone/a& r Lot BIk. Addition for the following purpose Addition to Vial le lz Residence Contractor •n1tc /Overholt Construction. Inc. tuha�a� '∎TAKE NOTICE White: Owner No chenl e, shall be made In Green: Lending Agency 4jh en: wWlnpwMhout OoId Contraaro GARFIELW COUNTY ING DEPARTMENT a, w ■ tW k.ta Yellow Building r Department // ,. ✓ p LD / g�* p - r,.. frop11M SMinp QtNCMI. Pink Assessor By \ �a.� r.�. +. "...;f'