Loading...
HomeMy WebLinkAbout4718 N 047''" GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 9th Street Suite 303 - - - Glenwood Springs, Colorado 81601 (303) 945-8212 Job Address V Limberpine Circle, Monument Creek Village II, Battlement Mesa Nature of Work Building Permit Use of Building Single Family Dwelling Unit Owner Battlement Mesa Partners Contractor Battlement Mesa Homes, Inc. Amount of Permit: $ 765,60 Date: April 20,. 1993 Permit: 464.00 Plan 301.60 S. Archuleta Clerk White - Tress. - - Canary- Office Pink - Applicant Gold- Duplicate GARFIELD COUNTY APPLICATION FOR BUILDING'PERMIT �/ PERMIT NUMBER please print or type DATE March 18 199 Assessor's Parcel # TO BE FILLED OUT BY APPLICANT PLOT PLAN ADDRESS 27 Limberpine Circle NOTE: Show easements, property line dimensions, SUBDIVISION Monument Creek Village II - all other structures, specify north, and street C FILING # 1 LOT # 2 BLOCK # q name. For odd shaped lots, or if space is U TAX SCHEDULE # too small, provide separate plot plan. LEGAL (SEC /TRN /RNG) # OF BUILDINGS NOW ON PARCEL 0 - USE OF BUILDINGS NOW ON PARCEL n / a g NAME Battlement Mesa Partners • MAILING ADDRESS P. O. Box 6000 'o ( CITY Battlement Mesa PHONE 285 -7330 m w NAME Battlement Mesa Homes, Inc. 27 Limberpine Circle z ADDRESS P. O. Box 6000 CITY Battlement M :sa w w NAME Battlement Mesa Homes, Inc. See Attached c H ADDRESS P. O. Box 6000 g (CITY Battlement Mesa E rHONE 285 - 7330 LICENSE # CLASS OF WORK NEW RR ALTERATION ADDITION DEMOLISH REPAIR MOVE MOBILE HOME (make /model) _ S.F. OF BUILDING X13,75 S.F. OF LOT 7500 /{'O.F FLOORS 1 HEIGHT ia'6 # OF FAMILY UNITS 1 # OF BEDROOMS 2 INTENDED USE OF BUILDING Single far rily resid GARAGE: SINGLE DBL CARPORT: SINGLE DBL FRONT PROPERTY LINE FIREPLACE DOCUMENTS ATTACHED _ STREET NAME /ROAD NUMBER Limberoine Circle WATER SUPPLY Battlement Mesa Metrn Diqtrint CHECK IF CORNER LOT _ DRIVEWAY PERMIT DESCRIPTION OF WORK PLANNED single family SITE PLAN Attached w /attached garage, site work & landscaping BUILDING PLANS Attached SANITARY SEWER CLEARANCERattlement Mega Metrn Dist. I hereby acknowledge that I have read this ON SITE SEWAGE DISPOSAL PERMIT application and the above is correct and I OTHER DOCUMENTS (specify) agree to comply with all county ordinances and tate laws regulating building construction Q •, `,: ' SIGN; TURE FOR OFFICE USE ONLY VALUATION ILA 1 11 1 9-,01) FLOOD HAZARD PERMIT FEE $ PLAN CHECK FEE $ CERTIFIED BLDG ELEVATION TOTAL FEE $7/ .40 SCHOOL IMPACT FEE $ X 1 , 4. SPECIAL CONDITIONS DATE PERMIT ISSUED ZONING DISTRICT � PROBLEMS' WITH PERMIT TYPE OF OCCUPANCY , 3 . TYPE OF CONSTRUCTION V N ADDITIONAL INFORMATION NEEDED S.F. OF BUILDING/11:r_ S.F. OF LOTArraj4 MAX. HEIGHT g -I-• — ROAD CLASS. CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR SETBACKS FROM PROPERTY LINE: FRONT ,4m c I4 OR ENGINEER REAR RIGHT LEFT - OFF STREET PARKING SPACES REQUIRED wL BUILDING APPROVEDy - 4 - / , 3 - 9 3 APPROVED: QJ 1� DEPARTMENT DATE PLANNIN ETMENT DATE 1.111Pirr >5/14, 7 - 7 ../. 24 7— • 4_ 7, • Or 3ju-c" / 3, 3 i„, 17 1 ,, ‘,727V 7 12 1 . 1 _41118 i 4_ 3 ! 9 C; A :6/ 11 Z7$± 3 - 3) 2-:„2._ j yti fL - Sill .3 0 _ - ' • 4 9 r C X I O ? C 1 ?` , 7 •/,,- 0 1 120 toc.'2. gs 4 6 a -1 4H1N 1s2 /nIkvia ,•• ' P 117.1"Fir ( Ai OS II 6,c? C3 -rll 4124-to CIA c).. / 2J fit' 4,1 = :2 f J 9 9' s -, r c } — leg, 3 ÷ )1 E 6 9 1 47, 7 ( f t 0 n _ t ' .7 g /, 3 S 7 / % 1 = �r '�4, _ , 37, _ C3- C) p ., ,,,, } ),,,r, i..4 i, , .0 el O1tt-1 1 7 4 ct t 0 1 :so 11 LOT 2, BLOCK N Mc Vlr N `r ' e'. } / - ►eP .. ''i pp V .. ► ` ' i 7 - s e I 4 SL R �.. "it h 26 • ' 4,1` SV i ' • . . , , • t i 1 t • .,-1, ,�' 1 ,, IA i,. •4 7 ,- !' , '1'47 S Z + L, J',A it'';' .r a. A. 1 1 � ' 'I 5 . PATIO MOMS ` .. A ti? : e' r L ' + ,t 4 i , PLAN 2 , I' . • 4r, :q.;..� • ' .,. '� , I M � _+ 1 ••••-• , 1 41. 4. : 1:411I .. 4 ir . 1 • I °, % '� , +} C� •t- a., i Y w. _ t I � ` S �` < �.. C lI' t r . ., P 4 ® 4 1y }. 4 w ..• � Fs� • 4 • • f ' '/' . .._ ,' • • • a e t "1. e • a . rill T • 1• f t r f,' r N.'" - y s r' ; .t jy ela, ,A•l„ ter` r • 2 4 ' • ` _ . 1! . t • ' C' z. • r' , M1. ' Y • • - {' dui +C _ '4 , • ,, r /,n LOCATI 7 L = -� PERMIT fl__ OWNER m> . CONTRACTOR THE FOLLOWING ITEMS MAY RAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH TIIE PROVISIONS OF TIIE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1908 EDITIONS OF TIIE CODES. THESE ITEMS ARE REQUIREMENTS FOR R -3 OCCUPANCIES ONLY (ONE AND TWO FAMILY DWELLINGS) AND ARE NOT ALL INCLUSIVE OF TIIE CODE REQUIREMENTS, BUT ARE MEANT AS A GUIDE TO SOME OF THE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE REQUIREMENTS. TIIE APPROVED PLANS RETURNED TO YOU SHALL BE KEPT AT THE BUILDING SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE CONTACT TIIE COLORADO ELECTRICAL INSPECTOR. - TIIERE SHALL BE A F1NAL. INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES WHEN COMPLETED AND READY FOR OCCUPANCY AND USE - UBC SEC. 305. (d). 1. Concrete for foundations and load bearing slabs is required to be 3000 psi in 28 days - UDC Chapter 26. Mortar and grout shall be in accordance with UDC Chapter 24 & Table 24 -A and 24 -5. ' 2. Masonry units, mortar, and grout shall be protected, during cold weather in accordance with UDC Sec. 2404 (c). Concrete shall be protected during cold or hot weather in accordance with UBC Sec. 2605 (f) and (g). 3 Minimum concrete and /or masonry foundation reinforcement requirements are / shown on the attachment. (Note: these minimums apply only if a foundation , soils investigation is not performed and the soils are assumed to have an expansion index of , 20.or. less and footing loads less than 2000 lbs /linear foot - UDC Sec.. 2904 (a) and (b) and Sec. 2906. Foundation frost protection is 30" from finished grade to top of footing - UDC 2907 (a). Foundations shall extend a min. of 6" above finished grade - UBC 2907 (d). 6. Provide for the control and drainage of surface water away from the building '- UBC 2907 (f). 7. Foundation walls enclosing a basement below grade shall be damp - proofed on the exterior with approved materials - UBC Sec. 1707 (d). - - -- 11 . Foundation plates or mills shall be redwood or pressure treated wood (UBC / 2516 (c)), and shall be bolted to the foundation with not less than 1/2" die bolts embedded at least 7" into concrete or masonry, spaced not more than ' 6 feet apart, min. of 2 bolts per piece and within 12" of each end of piece - UBC 2907 (f). 9. Exterior concrete or masonry piers shall extend 0" min. above grade unless the posts or columns which they support are treated or decay resistant wood. Columns and posts located in basements shall be supported by concrete piers or metal pedestals extending 6" min. above earth and 1" min. above floor unless treated pr. decay resistant wood - UBC Sec. 2516 (c) 4. 10: Manufactured trusses, and manufactured joists and beams (i.e. TJI /Micro- ,,,./. Lams, BCI /Versa -Lams, Glu -Lams, etc.), shall be sized and installed in accordance with the manufacturers requirements. 11. Wood joists or floor beams located closer than 10" or wood girders closer than 12" to the ground in crawl spaces shall be treated or decay resistant wood - UBC Sec. 2516 (c) 2. 12. Girders supported by masonry or concrete shall have 1/2" air space at top, sides, and ends unless treated or decay resistant wood - UBC Sec. 2516 (c) 5. Ends of beams and girders shall have min. 3" of bearing on masonry or concrete - UBC Seq. 2517 (c). 13. Floor joists under and parallel to bearing partitions shall be doubled UDC 2517 (d) 5. 11. Floor joists require full depth solid blocking and must lap a min. of 3" over bearing supports - UDC 2517 (d) 3. 0 1; 0 /Beams, roof rafters, and ceiling and floor joists shall be supported , laterally in accordance with UDC 2506 (h). 1 Columns, posts, beams, and girders shall have positive connections provided to ensure against both uplift and lateral displacement - UBC Sec. 2516 (m). 0. 1 . 7 0 / Ends of floor joists shall have 1 1/2" min. bearing on wood _or metal and no . less than 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2. 10. Notches on the ends of floor joists - max. 1/4 joist depth. Bored holes not within 2" of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located in middle 1/3 span - UBC Sec. 2517 (d) 3. 19. Floor joists and /or roof rafters are insufficient for the span - UBC Table 25 -V -J -1 and UDC Standards. 20. Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UDC elo Sec. 2305 (d) -dead loads shall be an required In USC Sec. 2305. ,tolloor live load shall be 40 psf - 1100 Sec.2304 (a) and fable 23 -A -1 - dead loads shall be as required in UBC Sec. 2304. 2 Basic wind speed shall be BO mph - UBC Sec. 2311. 1 3. Readers over wall openings 4' wide or less shall be doubled 2" framing lumber on edge. Over. 4' wide the header shall be sized for the span - UBC Sec. 251.7 (g) 5. 24 Bearing walls supporting two floor loads are required to be ix min. of 3" x 4 "or 2 "x 6" studs with a max. spacing of 16" on center -UBC Sec. 2517 (g) 1. 25. Wood studs may be cut or notched to a depth not exceeding 25% of width in exterior walls and bearing partitions and not exceeding 40% of width in non- bearing partitions - UBC Sec. 2517 (g) 8. 26. Wood studs may have bored holes no greater in diameter than 40% of stud width, 60% of width of doubled studs (but not more than 2 successive doubled studs). No holes shall be bored nearer than 5/8" to edge of stud - UBC Sec. 2517 (g) 9. 27. Wall bracing required both sides of each corner and every 25 lineal feet - the braced panel must be a min. of 48" in width perpendicular to studs - UBC Sec. 2517 (g) 3. 20. Approximate min. insulation values are R -19 walls, R -25 roofs, and R -11 �• floors over unheated space - see plans for more specific requirements - "Colorado Energy Conservation Standards." 29. Foam plastic insulation shall be separated from the building interior, including attics and crawl spaces, in accordance with UBC Sec. 1712. Other insulation (including duct and plenum insulation and coverings per UMC Chapter 10) including facings shall meet the requirements of UBC Sec. 1713. 30. - Masonry and stone veneer units (5" max. in thickness) shall have min. size of No. 22 gauge by 1" galv. metal ties or No. 9 gauge galv. wire ties and spaced to support not more than 2 sq. ft. of wall area but not more than 24" on center horizontally. When applied over stud construction, the studs shall be max. of 16" on center. Approved building paper must be applied over the sheathing, or studs - UBC Sec. 3006 (d). 31. Ceiling height is required to be 7'6" in all rooms except kitchens, halls, bathrooms, and storage areas which may be 7'0" min. - UBC Sec. 1207 (a). - - - -- 32. Min. stairway headroom clearance is 6'8" - UBC Sec. 3306 (p). 33. Min. stairway Width is 36" - UBC Sec. 3306 (b) and min...landing dimension in the direction of travel must also be 36" - UDC Sec. 3306 (g). 34. Stairways min, run 9 "; max. rise 8 "; max. variation in rise and run 3/8" - UDC Sec. 3306 `(c). 35. Enclosed usable: space under interior and exterior stairways shall be protected on the enclosed side as required for one -hour fire - resistive construction - 'UBC Sec. 3306 (m). Fire stops shall be provided in accordance with UBC Sec. 2516 (f) 2c. 36. Stairway handrails: min. height 34 "; max. height 38 "; handgrip portion shall • be not less than 1 1/2" nor more than 2" in x- section dimension. Min. of one handrail required on all stairways with more than three risers. Min. 1 1/2" space required between wall and handrail - UDC Sec. 3306 (j). 37. Guardrails of 36" min. height shall be installed at unenclosed floor openings and open sides of stairways, landings, ramps, decks or porches more than 30" above grade or floor below. Open guardrails shall have a pattern such that a sphere 6" in dia. cannot pass through - UDC Sec. 1711. 30. Under -floor (crawl space) cross ventilation is required equal to 1 sq. ft. for each 150 sq. ft. of under -floor area - UDC Sec. 2516 (c) 6. 39. Under -floor areas shall be provided with a min. 18" by 24" access opening - UBC Sec. 2516 (c) 2. 30" by 30" min. if mechanical equip. in under -floor area - UMC Sec. 709'. 40. 11 sleeping rooms below the fourth story without a door opening to the exterior shall have at least one operable window that meets the following requirements: MINIMUM clear opening: 5.7 sq. ft. MAXIMUM sill height: 44" MINIMUM net Blear opening height: 24" (x34 1/4" = 5.7 sq.ft.) MINIMUM net clear opening width: 20" (x41" = 5.7 sq. ft.) This also applies to basement sleeping rooms - UBC Sec. 1204. 41. Glazing in hazardous locations as defined in UDC Sec. 5406 (glazing in doors and adjacent to doorways, and glazing in windows located within 18" vertically of a walking surface) shall be safety glazed or protected. 42. Glass in sloped glazing (more than 15 from the vertical) and skylights shall meet the requirements of UDC Chapter 34. Skylights and roof and wall panels of light- transmitting plastics shall meet the requirements of UBC Chapter 52. Provide combustion air for fuel burning equipment per UMC Chapter 6. Pressure relief valves and /or combination pressure /temperature relief valves shall be provided with a drain line to a floor drain with min. 1" air gap 1 , or extended to the exterior of the building - UPC Sec. 1007. 45 omestic dishwashing machines shall not be directly connected to a drain or 45 disposer without the use of an approved airgap - UPC Sec. 608 (d): 46. Fuel burning appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed space opening into such room or space* UPC Sec. 1309 and UMC Se9. 704 (unless listed for such use). 47. Appliances (including space heating and water heating equipment) shall be accessible for repair and removal in accordance with the UMC. 40. LPG fueled appliances shall not be installed in a pit, under -floor (crawl) space, or basement - UMC Sec. 504 (f). 49. Appliances located in a garage (or in an enclosure opening into a garage) ( shall be located out of the normal path of vehicles or protected from damage. Any portion of the appliance creating a flame, spark or glow shall be installed a min. of 18" above the garage floor - UMC Sec. 500. 50. Each water closet stool shall be located in a clear space not less than 30" in width and 24" in front of stool - UBC Sec. 511 (a). 51. Toilet rooms without operable windows shall be equipped with an exhaust s oor system ducted to the exterior - UBC Sec. 1205 (c). 52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbent surface to a height of 70" min. above the drain inlet - UDC Sec. 510 (b). Water.- resistent gypsum board shall not be used over vapor barriers, in saunas or steam rooms, or on ceilings - UDC Sec. 4712. 53. Attic access opening of not less than 22" by 30" is required - UDC Sec. 3205 (a). 30" by 30" if mechanical equip. in attic space - UMC Sec. 700. 54. Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150 of the area of the space ventilated. The area may be 1/300 if provided equally at lower and upper portions of the space with min. 3' vertical separation of locations - UDC Sec. 3205 (c). 55. Garage side of common wall between living space and garage shall be finished with materials approved for one -hour fire- resistive construction. This also applies to ceilings and bearing walls if living space above the garage. Self closing min. 1 3/8" solid , tight fitting door is required between house and garage 11PC 503 (d). 3. or Electrically wired, interconnected smoke detectors are required in all sleeping room access areas, near the top of stairways in upper levels, and near the bottom of stairways to basements - UBC Sec. 1210 (a). 57. Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UBC j Chapter 37. 58. Masonry and concrete fireplaces and barbecues shall meet the requirements of UDC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed as a supporting member - UBC Sec. 3703 (a). 59. 60. COPIES OF TIIE ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items above or below are available upon request). Excavations, fills, foundations, and retaining walls - UDC Chapters 23 and 29. Retaining walls - UDC Sec. 2308 (b) and 2907 (g) 4. Roof coverings and drainage - UBC Chapter 32 (Roof drains sized in accordance with UPC Appendix 0). Roof sheathing -UBC Sec. 2516 (1). Wood combined with (supporting) masonry or concrete - UDC Sec. 2515. Floor sheathing - UBC Sec. 2516 (h). Wiring in plenums - UMC Chapter 10 and NEC. Fire and draft stops - UBC Sec. 2516 (f). Nailing requirements for connecting wood members - UDC Sec. 2516, Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish chutes - UDC Sec. 1706. Exterior wall coverings and exterior weather protection - UDC Sec. 1707 (d) and 2516 (g). Interior application of gypsum wallboard and interior and exterior application of lath and plaster - UBC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in • accordance with manufacturers requirements. Landings and floor level at doors - UDC Sec. 3304 (i). Cross connection control and back flow prevention - UPC Sec. 1002 and 1003. Treated Wood Foundation Systems - UDC Standard 29 -3. • INSPECTION WILL NOT DE MADE UNLESS THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT AFIELD COUNTY, COLORAD Date Issuer' ° Zoned Area AID Permit No AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction •f the above described structure, the permit may then be revoked by notice from t h, b t ; uiI • Ins its d I l ED A I FL BE NULL AND VOID, Use - • '�'�°' Address 'Forr Legal � Description Ari P' A. 4 Owne, , Vilest 0 1 r /€ (S Contractor I! (St s o •ri Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering Electric -Final (by STATE A`f E inspector) Footing 4 - 73 �� s � _-s S a tl �-- �' Foundation GI__ 2'7- 73 J -rte MASTER PLUMBER'S LICENSE if Plumbing- Underground Gas Piping .2, /, Bleating Ventilation P g 5 Frame (1`. ? / - `$ < 93 r ✓y Insulation g — 24i- `13 CJ Plumbing -Rough , �- _ � f . Drywall Electric -Rough - j 6. y (by STATE inspector) AFL,/ Final g—ar 3,7 • ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. TILLS PERMIT IS NOT TRANSFERABLE Phone 945 -8212 109 8th Street, County Courthouse, Glenwood Springs, Colo. APP R O ED DO NOT DESTROY THIS CARD Date ,A. . A' BY "rAs - - IF PLACED OUTSIDE - COVER WITH CLEAR PLASTIC T _ ! I i C � I, k, fr . i �Ii 1.) t l BUILDING PERMIT } � +y GARFIELD COUNTY, COLORADO a Date Issued ? 3 Area Permit No �k.J I AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees t comply with all laws and regulations related to the zoning, location; construction and' erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the Count _Building Inspe for an MMED ATTI t BECOME NULL AND VOID, { Address or Legal Description 1 i Uwner u� I Setbacks Frorit Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. s. INSPECTION 'RECORD Zoning Roof Covering - . - Electric -Final anal (:} ,., ..5.: j Fo // 3o- pD zya\ Foundation `A s 70 c „ 1...... Plumbing- Underground 2 7- i 1 as Piping Heating Ventilation _ ' ' Frame ,�/ Insulation Plumbing -Rough J 7 1 7 Drywall Final ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING — WHETIIER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945 -8212 109 8th Street, l.( Courthouse, Glenwood Springs, Colo. APPROVED ) j:'O : ETROY.II “i, Dated' B y a 0eJ IFPLACEDOUTSIDE - COVER WITH CLEAR PLASTIC W • � CERTIFICATE OF OCCUPANCY ., . N: 2 0 9 8 BUILDING DEPARTMENT '° character No change in the or a <r nr o= GARFIELD COUNTY, COLORADO It it q building shall be mode without n Certificate Issued Without Fee • 010=ctpnncy rune See. 302) • - August 2 19 93 • @ Permission is hereby granted to _ -aay m N1Qe ast g PartTL6re l. Building Permit No. 4718 _Zone District_. PIIp ' • { 41 situated at • 27 Limberpine Circle Battlement Mesa Lot 2 Blk. 3 . Addition P._ - for the following purpose S1 ngLe—Pam11y_Pube111 lareln NeNre et i l • U p) .(r Co nlractor Battlement Mesa Homes, Inc. • Issuance of a eerhersle of Occupancy mall ow be construed as an approval 2 one nmvsnnv ormacmle nrnrmxcr a' r rho inrnna nn f // 7 / 1 Cerrremee nme give authority the to l provisions vv �'jj fill the GAq FIEL0.Cb %TV�dUICUfNC BEPARTIAEN uf this ate. nr of ordinances l ,Hall not be 1y11 77// (OBC Sec JOAO f While; Owner Green Lending Agency Yellow: Building Department Pink: Assessor Gold Contractor ii , \ ' i- ancrcar • • • • • • • • • • • • • • • • • • I 1