GARFIELD COUNTY
BUILDING, SANITATION and PLANNING DEPARTMENT
109 9th Street Suite 303
- - - Glenwood Springs, Colorado 81601
(303) 945-8212
Job Address V Limberpine Circle, Monument Creek Village II, Battlement Mesa
Nature of Work Building Permit
Use of Building Single Family Dwelling Unit
Owner Battlement Mesa Partners
Contractor Battlement Mesa Homes, Inc.
Amount of Permit: $ 765,60 Date: April 20,. 1993
Permit: 464.00
Plan 301.60
S. Archuleta
Clerk
White - Tress. - -
Canary- Office
Pink - Applicant
Gold- Duplicate
GARFIELD COUNTY
APPLICATION FOR BUILDING'PERMIT �/
PERMIT NUMBER
please print or type DATE March 18 199
Assessor's Parcel #
TO BE FILLED OUT BY APPLICANT PLOT PLAN
ADDRESS 27 Limberpine Circle NOTE: Show easements, property line dimensions,
SUBDIVISION Monument Creek Village II - all other structures, specify north, and street
C FILING # 1 LOT # 2 BLOCK # q name. For odd shaped lots, or if space is
U TAX SCHEDULE # too small, provide separate plot plan.
LEGAL (SEC /TRN /RNG) # OF BUILDINGS NOW ON PARCEL 0
- USE OF BUILDINGS NOW ON PARCEL n / a
g NAME Battlement Mesa Partners
• MAILING ADDRESS P. O. Box 6000
'o ( CITY Battlement Mesa PHONE 285 -7330
m w NAME Battlement Mesa Homes, Inc. 27 Limberpine Circle
z ADDRESS P. O. Box 6000 CITY Battlement M :sa
w
w NAME Battlement Mesa Homes, Inc. See Attached
c
H ADDRESS P. O. Box 6000
g (CITY Battlement Mesa
E rHONE 285 - 7330 LICENSE #
CLASS OF WORK
NEW RR ALTERATION ADDITION
DEMOLISH REPAIR MOVE
MOBILE HOME (make /model) _
S.F. OF BUILDING X13,75 S.F. OF LOT 7500
/{'O.F FLOORS 1 HEIGHT ia'6
# OF FAMILY UNITS 1 # OF BEDROOMS 2
INTENDED USE OF BUILDING Single far rily resid
GARAGE: SINGLE DBL CARPORT: SINGLE DBL FRONT PROPERTY LINE
FIREPLACE
DOCUMENTS ATTACHED _ STREET NAME /ROAD NUMBER Limberoine Circle
WATER SUPPLY Battlement Mesa Metrn Diqtrint CHECK IF CORNER LOT _
DRIVEWAY PERMIT DESCRIPTION OF WORK PLANNED single family
SITE PLAN Attached w /attached garage, site work & landscaping
BUILDING PLANS Attached
SANITARY SEWER CLEARANCERattlement Mega Metrn Dist. I hereby acknowledge that I have read this
ON SITE SEWAGE DISPOSAL PERMIT application and the above is correct and I
OTHER DOCUMENTS (specify) agree to comply with all county ordinances
and tate laws regulating building construction
Q
•, `,:
'
SIGN; TURE
FOR OFFICE USE ONLY
VALUATION ILA 1 11 1 9-,01) FLOOD HAZARD
PERMIT FEE $ PLAN CHECK FEE $ CERTIFIED BLDG ELEVATION
TOTAL FEE $7/ .40 SCHOOL IMPACT FEE $ X 1 , 4. SPECIAL CONDITIONS
DATE PERMIT ISSUED
ZONING DISTRICT � PROBLEMS' WITH PERMIT
TYPE OF OCCUPANCY , 3 .
TYPE OF CONSTRUCTION V N ADDITIONAL INFORMATION NEEDED
S.F. OF BUILDING/11:r_ S.F. OF LOTArraj4
MAX. HEIGHT g -I-• — ROAD CLASS. CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR
SETBACKS FROM PROPERTY LINE: FRONT ,4m c I4 OR ENGINEER
REAR RIGHT LEFT -
OFF STREET PARKING SPACES REQUIRED wL
BUILDING APPROVEDy - 4 - / , 3 - 9 3 APPROVED: QJ 1� DEPARTMENT DATE PLANNIN ETMENT DATE
1.111Pirr
>5/14,
7 - 7 ../. 24 7— •
4_ 7,
•
Or 3ju-c" / 3, 3 i„,
17 1
,, ‘,727V 7 12 1 . 1 _41118 i 4_
3 ! 9
C;
A
:6/ 11 Z7$±
3 - 3) 2-:„2._
j yti fL
- Sill .3 0
_ - ' • 4 9 r C X I O ? C 1
?`
,
7 •/,,-
0
1
120 toc.'2. gs 4 6
a -1 4H1N 1s2
/nIkvia
,•• ' P 117.1"Fir (
Ai
OS II
6,c? C3 -rll 4124-to CIA c).. / 2J fit'
4,1 = :2 f
J
9 9' s -, r c } — leg, 3
÷ )1 E 6 9 1 47, 7 (
f t 0
n
_ t ' .7 g /, 3 S 7 / % 1 = �r '�4, _ , 37, _ C3- C)
p ., ,,,, } ),,,r, i..4 i, , .0 el
O1tt-1 1 7 4 ct t 0
1
:so 11
LOT 2, BLOCK N
Mc Vlr N `r
' e'. } / -
►eP .. ''i pp V .. ► ` ' i 7 - s e
I 4 SL R �..
"it h 26 • ' 4,1` SV i ' • . . , , • t i 1
t • .,-1, ,�' 1 ,, IA i,. •4 7 ,- !' ,
'1'47 S Z + L, J',A it'';' .r a.
A.
1 1
�
' 'I 5 . PATIO MOMS `
.. A ti? : e' r L
' + ,t 4 i , PLAN 2 , I' . • 4r, :q.;..� • ' .,. '� , I M � _+ 1 ••••-• , 1 41. 4. : 1:411I
.. 4 ir .
1 • I °, % '� , +} C� •t- a., i Y w. _ t I � ` S
�` < �.. C
lI' t
r . ., P 4 ® 4 1y }.
4 w ..• � Fs� •
4 • •
f ' '/' . .._ ,' • • • a e t "1. e • a
. rill T
•
1• f t
r f,' r
N.'"
- y s r' ; .t jy ela,
,A•l„ ter` r • 2 4 ' • ` _ . 1! . t • ' C' z. • r' ,
M1.
' Y •
• - {' dui +C _ '4 , • ,,
r
/,n LOCATI 7 L = -�
PERMIT fl__ OWNER m> .
CONTRACTOR
THE FOLLOWING ITEMS MAY RAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH
TIIE PROVISIONS OF TIIE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS
BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1908 EDITIONS OF TIIE CODES.
THESE ITEMS ARE REQUIREMENTS FOR R -3 OCCUPANCIES ONLY (ONE AND TWO FAMILY
DWELLINGS) AND ARE NOT ALL INCLUSIVE OF TIIE CODE REQUIREMENTS, BUT ARE MEANT AS
A GUIDE TO SOME OF THE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE
REQUIREMENTS. TIIE APPROVED PLANS RETURNED TO YOU SHALL BE KEPT AT THE BUILDING
SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE
CONTACT TIIE COLORADO ELECTRICAL INSPECTOR. -
TIIERE SHALL BE A F1NAL. INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES
WHEN COMPLETED AND READY FOR OCCUPANCY AND USE - UBC SEC. 305. (d).
1. Concrete for foundations and load bearing slabs is required to be 3000 psi
in 28 days - UDC Chapter 26. Mortar and grout shall be in accordance with
UDC Chapter 24 & Table 24 -A and 24 -5. '
2. Masonry units, mortar, and grout shall be protected, during cold weather in
accordance with UDC Sec. 2404 (c). Concrete shall be protected during cold
or hot weather in accordance with UBC Sec. 2605 (f) and (g).
3 Minimum concrete and /or masonry foundation reinforcement requirements are
/ shown on the attachment. (Note: these minimums apply only if a foundation ,
soils investigation is not performed and the soils are assumed to have an
expansion index of , 20.or. less and footing loads less than 2000 lbs /linear
foot - UDC Sec.. 2904 (a) and (b) and Sec. 2906.
Foundation frost protection is 30" from finished grade to top of footing -
UDC 2907 (a).
Foundations shall extend a min. of 6" above finished grade - UBC 2907 (d).
6. Provide for the control and drainage of surface water away from the building
'- UBC 2907 (f).
7. Foundation walls enclosing a basement below grade shall be damp - proofed on
the exterior with approved materials - UBC Sec. 1707 (d). - - --
11 . Foundation plates or mills shall be redwood or pressure treated wood (UBC
/
2516 (c)), and shall be bolted to the foundation with not less than 1/2" die
bolts embedded at least 7" into concrete or masonry, spaced not more than '
6 feet apart, min. of 2 bolts per piece and within 12" of each end of piece
- UBC 2907 (f).
9. Exterior concrete or masonry piers shall extend 0" min. above grade unless
the posts or columns which they support are treated or decay resistant wood.
Columns and posts located in basements shall be supported by concrete piers
or metal pedestals extending 6" min. above earth and 1" min. above floor
unless treated pr. decay resistant wood - UBC Sec. 2516 (c) 4.
10: Manufactured trusses, and manufactured joists and beams (i.e. TJI /Micro-
,,,./. Lams, BCI /Versa -Lams, Glu -Lams, etc.), shall be sized and installed in
accordance with the manufacturers requirements.
11. Wood joists or floor beams located closer than 10" or wood girders closer
than 12" to the ground in crawl spaces shall be treated or decay resistant
wood - UBC Sec. 2516 (c) 2.
12. Girders supported by masonry or concrete shall have 1/2" air space at top,
sides, and ends unless treated or decay resistant wood - UBC Sec. 2516 (c)
5. Ends of beams and girders shall have min. 3" of bearing on masonry or
concrete - UBC Seq. 2517 (c).
13. Floor joists under and parallel to bearing partitions shall be doubled UDC
2517 (d) 5.
11. Floor joists require full depth solid blocking and must lap a min. of 3"
over bearing supports - UDC 2517 (d) 3.
0 1; 0 /Beams, roof rafters, and ceiling and floor joists shall be supported ,
laterally in accordance with UDC 2506 (h).
1 Columns, posts, beams, and girders shall have positive connections provided
to ensure against both uplift and lateral displacement - UBC Sec. 2516 (m).
0. 1 . 7 0 / Ends of floor joists shall have 1 1/2" min. bearing on wood _or metal and no .
less than 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2.
10. Notches on the ends of floor joists - max. 1/4 joist depth. Bored holes not
within 2" of top or bottom of joist and hole diameter no larger than 1/3
depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not
located in middle 1/3 span - UBC Sec. 2517 (d) 3.
19. Floor joists and /or roof rafters are insufficient for the span - UBC Table
25 -V -J -1 and UDC Standards.
20. Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UDC
elo Sec. 2305 (d) -dead loads shall be an required In USC Sec. 2305.
,tolloor live load shall be 40 psf - 1100 Sec.2304 (a) and fable 23 -A -1 - dead
loads shall be as required in UBC Sec. 2304.
2 Basic wind speed shall be BO mph - UBC Sec. 2311. 1
3. Readers over wall openings 4' wide or less shall be doubled 2" framing
lumber on edge. Over. 4' wide the header shall be sized for the span - UBC
Sec. 251.7 (g) 5.
24 Bearing walls supporting two floor loads are required to be ix min. of 3" x
4 "or 2 "x 6" studs with a max. spacing of 16" on center -UBC Sec. 2517 (g) 1.
25. Wood studs may be cut or notched to a depth not exceeding 25% of width in
exterior walls and bearing partitions and not exceeding 40% of width in non-
bearing partitions - UBC Sec. 2517 (g) 8.
26. Wood studs may have bored holes no greater in diameter than 40% of stud
width, 60% of width of doubled studs (but not more than 2 successive doubled
studs). No holes shall be bored nearer than 5/8" to edge of stud - UBC Sec.
2517 (g) 9.
27. Wall bracing required both sides of each corner and every 25 lineal feet -
the braced panel must be a min. of 48" in width perpendicular to studs - UBC
Sec. 2517 (g) 3.
20. Approximate min. insulation values are R -19 walls, R -25 roofs, and R -11
�• floors over unheated space - see plans for more specific requirements -
"Colorado Energy Conservation Standards."
29. Foam plastic insulation shall be separated from the building interior,
including attics and crawl spaces, in accordance with UBC Sec. 1712. Other
insulation (including duct and plenum insulation and coverings per UMC
Chapter 10) including facings shall meet the requirements of UBC Sec. 1713.
30. - Masonry and stone veneer units (5" max. in thickness) shall have min. size
of No. 22 gauge by 1" galv. metal ties or No. 9 gauge galv. wire ties and
spaced to support not more than 2 sq. ft. of wall area but not more than 24"
on center horizontally. When applied over stud construction, the studs
shall be max. of 16" on center. Approved building paper must be applied
over the sheathing, or studs - UBC Sec. 3006 (d).
31. Ceiling height is required to be 7'6" in all rooms except kitchens, halls,
bathrooms, and storage areas which may be 7'0" min. - UBC Sec. 1207 (a). - - - --
32. Min. stairway headroom clearance is 6'8" - UBC Sec. 3306 (p).
33. Min. stairway Width is 36" - UBC Sec. 3306 (b) and min...landing dimension
in the direction of travel must also be 36" - UDC Sec. 3306 (g).
34. Stairways min, run 9 "; max. rise 8 "; max. variation in rise and run 3/8" -
UDC Sec. 3306 `(c).
35. Enclosed usable: space under interior and exterior stairways shall be
protected on the enclosed side as required for one -hour fire - resistive
construction - 'UBC Sec. 3306 (m). Fire stops shall be provided in
accordance with UBC Sec. 2516 (f) 2c.
36. Stairway handrails: min. height 34 "; max. height 38 "; handgrip portion shall •
be not less than 1 1/2" nor more than 2" in x- section dimension. Min. of
one handrail required on all stairways with more than three risers. Min.
1 1/2" space required between wall and handrail - UDC Sec. 3306 (j).
37. Guardrails of 36" min. height shall be installed at unenclosed floor
openings and open sides of stairways, landings, ramps, decks or porches more
than 30" above grade or floor below. Open guardrails shall have a pattern
such that a sphere 6" in dia. cannot pass through - UDC Sec. 1711.
30. Under -floor (crawl space) cross ventilation is required equal to 1 sq. ft.
for each 150 sq. ft. of under -floor area - UDC Sec. 2516 (c) 6.
39. Under -floor areas shall be provided with a min. 18" by 24" access opening -
UBC Sec. 2516 (c) 2. 30" by 30" min. if mechanical equip. in under -floor
area - UMC Sec. 709'.
40. 11 sleeping rooms below the fourth story without a door opening to the
exterior shall have at least one operable window that meets the following
requirements: MINIMUM clear opening: 5.7 sq. ft.
MAXIMUM sill height: 44"
MINIMUM net Blear opening height: 24" (x34 1/4" = 5.7 sq.ft.)
MINIMUM net clear opening width: 20" (x41" = 5.7 sq. ft.)
This also applies to basement sleeping rooms - UBC Sec. 1204.
41. Glazing in hazardous locations as defined in UDC Sec. 5406 (glazing in doors
and adjacent to doorways, and glazing in windows located within 18"
vertically of a walking surface) shall be safety glazed or protected.
42. Glass in sloped glazing (more than 15 from the vertical) and skylights
shall meet the requirements of UDC Chapter 34. Skylights and roof and wall
panels of light- transmitting plastics shall meet the requirements of UBC
Chapter 52.
Provide combustion air for fuel burning equipment per UMC Chapter 6.
Pressure relief valves and /or combination pressure /temperature relief valves
shall be provided with a drain line to a floor drain with min. 1" air gap
1 ,
or extended to the exterior of the building - UPC Sec. 1007.
45 omestic dishwashing machines shall not be directly connected to a drain or
45
disposer without the use of an approved airgap - UPC Sec. 608 (d):
46. Fuel burning appliances shall not be located in any room used or designed
to be used as a sleeping room, bathroom, or closet or any enclosed space
opening into such room or space* UPC Sec. 1309 and UMC Se9. 704 (unless
listed for such use).
47. Appliances (including space heating and water heating equipment) shall be
accessible for repair and removal in accordance with the UMC.
40. LPG fueled appliances shall not be installed in a pit, under -floor (crawl)
space, or basement - UMC Sec. 504 (f).
49. Appliances located in a garage (or in an enclosure opening into a garage)
( shall be located out of the normal path of vehicles or protected from
damage. Any portion of the appliance creating a flame, spark or glow shall
be installed a min. of 18" above the garage floor - UMC Sec. 500.
50. Each water closet stool shall be located in a clear space not less than 30"
in width and 24" in front of stool - UBC Sec. 511 (a).
51. Toilet rooms without operable windows shall be equipped with an exhaust
s oor system ducted to the exterior - UBC Sec. 1205 (c).
52. Showers and Tub /Shower enclosures shall have a smooth, hard, nonabsorbent
surface to a height of 70" min. above the drain inlet - UDC Sec. 510 (b).
Water.- resistent gypsum board shall not be used over vapor barriers, in
saunas or steam rooms, or on ceilings - UDC Sec. 4712.
53. Attic access opening of not less than 22" by 30" is required - UDC Sec. 3205
(a). 30" by 30" if mechanical equip. in attic space - UMC Sec. 700.
54. Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150
of the area of the space ventilated. The area may be 1/300 if provided
equally at lower and upper portions of the space with min. 3' vertical
separation of locations - UDC Sec. 3205 (c).
55. Garage side of common wall between living space and garage shall be finished
with materials approved for one -hour fire- resistive construction. This also
applies to ceilings and bearing walls if living space above the garage.
Self closing min. 1 3/8" solid , tight fitting door is required between house and
garage 11PC 503 (d). 3.
or Electrically wired, interconnected smoke detectors are required in all
sleeping room access areas, near the top of stairways in upper levels, and
near the bottom of stairways to basements - UBC Sec. 1210 (a).
57. Wood stoves and factory built chimneys, and manufactured fireplace units and
venting systems shall be installed in accordance with the manufacturers
listing requirements and inspected during installation UMC Chapter 9 and UBC j
Chapter 37.
58. Masonry and concrete fireplaces and barbecues shall meet the requirements
of UDC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any
structural load other than its own weight unless designed as a supporting
member - UBC Sec. 3703 (a).
59.
60.
COPIES OF TIIE ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items
above or below are available upon request).
Excavations, fills, foundations, and retaining walls - UDC Chapters 23 and
29.
Retaining walls - UDC Sec. 2308 (b) and 2907 (g) 4.
Roof coverings and drainage - UBC Chapter 32 (Roof drains sized in
accordance with UPC Appendix 0).
Roof sheathing -UBC Sec. 2516 (1).
Wood combined with (supporting) masonry or concrete - UDC Sec. 2515.
Floor sheathing - UBC Sec. 2516 (h).
Wiring in plenums - UMC Chapter 10 and NEC.
Fire and draft stops - UBC Sec. 2516 (f).
Nailing requirements for connecting wood members - UDC Sec. 2516,
Enclosure of elevator, vent, and dumbwaiter shafts, and clothes and rubbish
chutes - UDC Sec. 1706.
Exterior wall coverings and exterior weather protection - UDC Sec. 1707 (d)
and 2516 (g).
Interior application of gypsum wallboard and interior and exterior
application of lath and plaster - UBC Chapter 47. Manufactured wall and
ceiling covering systems (simulated stucco, etc.) shall be installed in •
accordance with manufacturers requirements.
Landings and floor level at doors - UDC Sec. 3304 (i).
Cross connection control and back flow prevention - UPC Sec. 1002 and 1003.
Treated Wood Foundation Systems - UDC Standard 29 -3.
•
INSPECTION WILL NOT DE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
AFIELD COUNTY, COLORAD
Date Issuer' ° Zoned Area AID Permit No
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with
all laws and regulations related to the zoning, location; construction and erection of the
proposed structure for which this permit is granted, and further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and
construction •f the above described structure, the permit may then be revoked by notice
from t h, b t ; uiI • Ins its d I l ED A I FL BE NULL AND VOID,
Use -
•
'�'�°'
Address 'Forr Legal � Description Ari P' A. 4
Owne, , Vilest 0 1 r /€ (S Contractor I! (St s o •ri
Setbacks Front Side Side Rear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
INSPECTION RECORD
Zoning Roof Covering
Electric -Final (by STATE A`f E inspector)
Footing 4 - 73 �� s � _-s S
a tl �--
�' Foundation GI__ 2'7- 73 J -rte MASTER PLUMBER'S LICENSE if
Plumbing- Underground
Gas Piping .2, /, Bleating Ventilation
P g 5
Frame (1`. ? / - `$ < 93 r ✓y Insulation g — 24i- `13 CJ
Plumbing -Rough , �- _ � f . Drywall
Electric -Rough - j 6. y
(by STATE inspector) AFL,/ Final g—ar 3,7 •
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
TILLS PERMIT IS NOT TRANSFERABLE
Phone 945 -8212 109 8th Street, County Courthouse, Glenwood Springs, Colo.
APP R O ED DO NOT DESTROY THIS CARD
Date ,A. . A' BY "rAs - -
IF PLACED OUTSIDE - COVER WITH CLEAR PLASTIC
T
_ !
I i C
� I, k, fr . i
�Ii 1.) t l
BUILDING PERMIT }
� +y GARFIELD COUNTY, COLORADO a
Date Issued ? 3 Area Permit No �k.J
I AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees t comply with
all laws and regulations related to the zoning, location; construction and' erection of the
proposed structure for which this permit is granted, and further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and
construction of the above described structure, the permit may then be revoked by notice
from the Count _Building Inspe for an MMED ATTI t BECOME NULL AND VOID,
{
Address or Legal Description 1
i
Uwner u�
I
Setbacks Frorit Side Side Rear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
s.
INSPECTION 'RECORD
Zoning Roof Covering
- . -
Electric -Final anal (:} ,., ..5.: j
Fo // 3o- pD zya\
Foundation `A s 70 c „ 1......
Plumbing- Underground 2 7- i 1
as Piping Heating Ventilation _ '
'
Frame ,�/ Insulation
Plumbing -Rough J 7 1 7 Drywall
Final
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING —
WHETIIER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945 -8212 109 8th Street, l.( Courthouse, Glenwood Springs, Colo.
APPROVED ) j:'O : ETROY.II “i,
Dated' B y a 0eJ
IFPLACEDOUTSIDE - COVER WITH CLEAR PLASTIC
W •
� CERTIFICATE OF OCCUPANCY
.,
.
N: 2 0 9 8 BUILDING DEPARTMENT
'° character No change in the or a <r nr o= GARFIELD COUNTY, COLORADO
It it
q building shall be mode without n Certificate Issued Without Fee •
010=ctpnncy rune See. 302)
•
- August 2 19 93
•
@ Permission is hereby granted to _ -aay m N1Qe
ast g PartTL6re
l. Building Permit No. 4718 _Zone District_. PIIp '
• {
41 situated at • 27 Limberpine Circle Battlement Mesa
Lot 2 Blk. 3 . Addition
P._ - for the following purpose S1 ngLe—Pam11y_Pube111
lareln NeNre et i
l
•
U p) .(r Co nlractor Battlement Mesa Homes, Inc. •
Issuance of a eerhersle of Occupancy mall ow be construed as an approval
2 one nmvsnnv ormacmle nrnrmxcr a' r rho inrnna nn f // 7 / 1
Cerrremee nme give authority the to l provisions
vv �'jj fill the GAq FIEL0.Cb %TV�dUICUfNC BEPARTIAEN
uf this ate. nr of ordinances l ,Hall not be 1y11 77//
(OBC Sec JOAO
f While; Owner Green Lending Agency Yellow: Building Department Pink: Assessor Gold Contractor ii
, \ '
i- ancrcar
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
I
1