Loading...
HomeMy WebLinkAbout5063 No. 5063 GARF1ELD GOUJVTY BUILDING, SANITATIONaadPLANNINGDEPAXTMENT 109 8th Strcet Suite 303 Glenwood Springs, Colorado 81601 (303) 9458212 Job Address 0098 Roan Creek Drive, Battlement Creek Village, Battlement Mesa Nature of Work Building Permit Use ofBuildi g Single Family Dwelling w /Double Garage Owner Bill Callister Contractor Witt Homes Amount of Permit$ 1112.93 Dale March 29, 1994 Permit: 674.50 Plan : 438.43 S. Archuleta Clerk p GAMELD COUNTY M A R _1 4 1994 1 I APPLICATION FOR BUILDING PERMIT '� �, � � PERMIT NUMBER ....506 3 � 4Islflf please print or type DATE 3 -03 -94 J 7 �7 /-9Y TO BE FILLED OUT BY APPLICANT PLOT PLAN ADDRESS _ Q98 Roan Creek Dr NOTE: Show easements, property line dlmensio: SUBDIVISION Battlement C aa k Vi11agp all other structures, specify north, and sire( ca d PILING 11 LOT A 6 BLOCK 11 1 name. For odd shnped lots, or if space is N TAX SCHEDULE N too small, provide separate plot plan. LEGAL (SEC /TWN /RNG) !1 OF BUILDINGS NOW ON PARCEL 0 W NAME Bill CaIl1St USE OF' BUILDINGS NOW ON PARCEL MAILING ADDRESS 109b Harris Dr. o CITY Craig, Colo PRONE :c x NAME Lincoln- DeVOre a w ADDRESS 1441 Motor CITY G. J. Attached to Plan a NAME Witt Homes ADDRESS P.O. Box 628 CITY Parachute, CO 81635 o PHONE 285 - 7536 LICENSE (i CLASS OF WORK 'EW X ALTERATION ADDITION DEMOLISH REPAIR _ MOVE _ MOBILE HOME (make /model) :;.F. OF BUILDING t}' %, OF LOT 40251 ;1 of FLOORS 1 _ HEIGHT . 20' !.' OP FAMILY UNITS 1 ' # OF BEDROOMS 3 INTENDED USE OF BUILDING Residence GARAGE: SINGLE _ DBLX CARPORT: SINGLE DBE FIREPLACE 1 - Gas — FRONT PROPERTY LINE DOCUMENTS ATTACHED STREET NAME /ROAD NUMBER Roan Creek Dr. WATER SUPPLY BNP CHECK IF CORNER LOT DRIVEWAY PERMIT Garfield c„ - _, • - O� DESCRIPTION OF WORK PLANNED SITE PLAN ATTACHED BUILDING PLANS ATTACHED SANITARY SEWER CLEARANCE BMP I hereby acknowledge that I have read this ON SITE SEWAGE DISPOSAL PERMIT N/A application and the above is correct and I 017(ER DOCUMENTS ( specify) agree to comply wi h all county ordinances Poandatio.a Plans _ and t.te law: e• Iating building constructi( , J / FOR OFFICE USE ONLY VALUATION 1/094/515-, FLOOD HAZARD PERMIT FEE $C74 /3C- -13LAN CHECK FEE $ £'Y. `/ + CERTIFIED BLDG ELEVATION TOTAL FEE $ / / / /,Z `T.JsdflooL IMPACT PEE $ 7721 SPECIAL CONDITIONS DATE PERMIT ISSUED ZONING DISTRICT � PROBLEMS WITH PERMIT / ( TYPE OF OCCUPANCY R- Ye, /1 -/ TYPE OF CONSTRUCTION '7 R ADDITIONAL INFORMATION NEEDED S.F. OF BUILDING - ,P•. Or LOT MAX. HEIGHT ROAD CLASS. CERTIFIED BY COLORADO REGISTERED LAND SURVEY()) SETBACKS FROM PROPERTY LINE: FRONT /1 (.15-/ OR ENGINEER REAR J - fl RIGHT /.: 67' LEFT f.- ;:,Err' OFF STREET PARKING SPACES REQUIRM3 . r Al'PROVED:.� H �,, //- ,.�,��/� - �S �>� , p " vl✓ 3- 2X7 -1 APPROVED: D TLDING DLPA I'MENT DATE PLANNING DEPARTMENT DATE 82' -0" 22' -0 9' -0" +3' -0 { 6' - 1 3' -0 i 78' -0" I 6' -0' I 75' -0' 1 12' -0 I 5 P2E o / /�� n // 20' FIG. \ COYFRE I V r K O h i t a t 78" FO ■ 16" FOOTING 16" FTG o In • a PS P6 P6 P6 r k a' —O" I I s' —G e' —G_ V GARAGE •0 F SLAB ON GRADE F k 511 IN 0 1 77 P5 P6 P6 P6 • 8' -0' a"--o 8' -0' I 16" FOOTING 12• FIG, - n G (; • 0 O 8 I O O 12" FTG. ' 34 ' FO 18' o 20' FTG to 1, 1 r i ya^ ,I L 12" FUMING ' P FOUNDATION PLAN '0,-0. I3. -0 "l 6' -0" I3 5. -0• 0" I 12 " -0' ` 74' —D' f I ! P2 3 PATIO 20' FIG. P3 tit- IN )IING 18" FTG. Z PAD SCHEDULE r� P1 = 14" X 14' X 10' P2 = 20' X 20' X 10' P6 P5 P3 = 26' X 26 X 10" _I.3.-=9" _ _ ( P4 = 24' X 24 X 10' PS = 28' X 28" X 10' IIIIII 111111 P8 = 32' X 32' X 10' e. 1 • g ^ _ Pe P6 P3 _ 6' -0' _ ' 6' 8' - 0_ I 1 _ 4 ir c.LINCOLN— DeVORE, INC. 20' FOOTING TG 72' F7G. By: Iti 99" Fir ' State of Colorado Designed by EDWARD M. MORRIS EI7 Soo Type: DEBRIS FAN, ALLUVIAL SANDY SILT SILTY CLAY, GRAVELS AND COBBLES rP1 11177' HOMES - CALLLSTER RES. LOT 8, BLOCK 1 BATTLEMENT CREEK BATTLEMENT MESA, CO LINCOLN 1441 MOTOR STREET LD DeVORE GRAND J COLORADO COLD. SHUN! GS- PUEBIA GEOLOGISTS m 80085 —J "IT 1 ° 2 a ' a an J.L. SPARKS Ea ' 1/8' = 1' —O" 011 3 -2 -1994 01021W0 E M. MORRIS tam= .r 3-7 -1994 NOTES FOR NON — EXPANSIVE SOILS Notes: *Dimensions should be taken from architectural plan except for foundation components. *Reinforcing to be continuous around the building as shown. Minimum lap of reinforcing at splices - 15 ". No gaps in the reinforcing will be permitted. Use Grade 60 steel. *Bends in reinforcing bars shall not be smaller than 6 bar diam. on the inside radius. *Separate floor slab from all structural portions of building with expansion joint or folded polyethylene film. *Surface drainage should be positive and rapid in directions away from the building at all points. The yard within 10' of the structure and all backfill to be sloped away from the structure at a minimum gradient of 2X. *Roof drains should be carried away from the building at least 5' past any backfill. Water shall not be allowed to stand or pond near the building during or after construction. Backfill shall not be flooded during or after construction. *All backfill shall be compacted to a minimum of 857. of the maximum Proctor density, ASTM D -1557. The only exception to this will be components of any peripheral drain. *Excavation should be observed to determine if soils over the building area are the same as those for which the building was designed. *Gravel pad should not be used beneath slab unless well drained. *Do not use dry wells on site, unless sited and approved by Geotechnical Engineer. *Foundation concrete shall have a minimum strength of 3000 psi placed with a maximum slump of 5 ". It shall be made using "Modified" Type II Cement or equal protection, with no Calcium Chloride added. *Planters, if any, should be well sealed and drained. *Reinforcing shall be observed by engineer prior to placing concrete. Structure will be reinforced as shown on plans. No changes in building loads, reinforcing or design shall be made after final inspection. *Refer to the soils letter for peripheral drain recommendations. *Prior to backfilling procedures, foundation walls should be allowed to cure a minimum of 7 days and be adequately supported by floor systems or other bracing. *Site Conditions, Limitations and Recommendations -for this site are presented in LINCOLN- DeVORE Report # 80085 -J, December 28, 1993_ These recommendations are considered a part of this foundation design and must be -followed. • 1 B" JOINT ISOL SILL P W/ A.B. a I 'It fl ■ N. CRAM. WL SPACE IM `` mg 0 1 ! n T 6 C h L SEE SEE PLAN l -LAN FTG. AT LOW WALL FM AT CRAWL SPACE 1 1 f 1 • 4'X REDWOOD 6"• CON C. OR ! 3 0 STL COLUMN DOWEL OR GROUND TREATED WOOD ,R HEIGHT b ! P AD . 12 „ - pa • SEE PLAN EA. WAY SEE PLAN 8" C/c EA. WAY DECK PAD CRAWLSPACE PAD LINCOLN— DeVDRE, INC. WITT HOMES — CALLISTER RES. LOT 6, BLOCK 1 BATTLEMENT CREEK By BATTLEMENT MESA, CO state of Colorado I LINCOLN 1441 MOTOR STREET Designed by. EDWARD M. MORRIS VT ED De VORE doui. GRA JCL COLORADO Soil Type: DEBRIS FAN, ALLUVIAL SANDY SILT gp PUEBLO �NGI g S1LTY CLAY, GRAVELS AND COBBLES 67313 80085 —J �m 2 ° 2 ow " J.L SPARKS I NO SCALE " 3 -2-1994 ao ®n R on EM. MORRIS 3-7 -1994 INSPECTION WILL NOT BE MADE UNLESS THIS CARD IS POSTED ON THE JOB j 24 HOURS NOTICE REQUIRED FOR INSPECTIONS , BUILDING PERMIT COUNTY, COLORADO � 6 Date Issue t AR A I,ELD oile Area ''"� Permit No " AGREEMENT In considera i on of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from t • . r . 'ping d ingIs �tor MM I, I, . X BE • E NU •� D VOID, Use -.. IM ((,� �} . Address��q� I.e al De iptiion 4 4 P , � A. 1 4 11 P f Ce • Mal • OwnerDi tl a �."I , [ ; s f er Contractor 10i fit 1 tree 5 Setbacks Front Side Side Rear This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD , 7i Zoning Roof Covering ` t: 11 Electric -Final (by STATE inspector) s`'; 0 ',,„z �, gJ - 3 o - 9 h � � �� 7) - /1 - ic i I Footin Foundation // 51jr � - /�.c. , �wt�r' Plumbing- Underground 12041'."'":2,a$ Gas Piping (o „ 74.l94 { ; Heating Ventilation J ;' Frame le - -7-- - 9 f" --v Insulation w Plumbing -Rough c` /7 -7 cd h Drywall -s -l4/ ,,,y,,,,, t z�' � Electric -Rough - e/ - G • a , s i} (by STATE inspector) Final Q- /-y�, ' ' ,' ; x ALL LISTED ITEMS MUST INSPECTED AND APPROVED BEFORE COVERING - x ` WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. I silk s 4 , t. i r. THLS PERMIT IS NOT TRANSFERABLE ' , N W . - : I. Phone 9 -8212 109 8th Street, County Courthouse, Glenwood Springs, Colo. 'P t' A P P ROV D DO NOTDEST OYTIIISCARD � i',, y r „ B Y � & mom i �K° Date A �`, kt a* F .._ I: ■ IF' PLACED OUTSIDE - COVER WITH CLEAR PLASTIC i SS ' -7,h",....4 - F . i I Y v ;,,f I 'b 1 ' ` ■ 1 + xr I i trite: ' 5 c ,f , r 'I trn �Ydt n /- ..."2.:: yt r " Ss A i$ - "�. K';'�'< ' s ' 1 ` . S ..-, r . :- . , ^ � c 2 1k . »N" •,.+a �. ; : i33 D .�d ,Tti . . ii�. • 0) Cd O U V C 1 r - - C C E f N O O O l+ � U 4 O 0 O 0 m U m r0 a O O b '0 0 N .o) L L U N 0 O O O oc � s+ bb T"�. p 6 R u - 0 Z 0 un co GA a > o el " 0 0 A 0 o 0 �j cd Ra o ``��ii v = ta b N .1-4 w 61 o �y O N 0 rn O. i` CO V 10 N JO 6) cal 4 -4 Li i- p , � o H k , 0 V cz 0 o O t M y z m • s La o bp CIL C saiiit ca ' "0 O a ' ro Q 0 a c A 3 Et T0 �> ono o� aJ t0 V a 'r o t. • .� "O Ts 4) • w ¢ Q c • �i y a q o x V �= 3 O D • o a 1 s. 0 ,a 4) • CO M 111111/4 ..0 CCS 0) .f j' . p q O Q u N U w A H y 0 e4.) 4. V 0 0 � • b cis E �. . = c G. (.0 r m 01 0 \ by v O 5 N c 0 + 0 - r N • O 0 0 0 1 0 ers • 4, Lea cn Co Y p.y O en C y L1 + 0 10 v h cn 9 O y 6 U U al 'II '•U V 4,1 9 m u ?l" O' W o .I 7 4 ^o en 0 . o tt N Dm 10 0 ca O u O N= m 0 r-4 0 C w w • zs o H 6 0 al 0 •• 0 0 a