Loading...
HomeMy WebLinkAbout5659 1 No, 5659 GARI' %FLU COUNTY BUILDING, SANITATION aml PLANNING DEPARTMENT 109 8th Street Sui lc 303 Glenwood Springs, Colorado 81601 (303) 945 -8212 Job Address 9929 Highway 82, Carbondale Nature of Work Rn i 1 ding_ Permit Use of Building Well House Owner Aspen Glen Golf Company Contractor Gould Construction Amount of Permit$ 1,632.67 Dale September 6, 1995 Permit: 989.50 Plan : 643.17 Paid $643.17 8 -24 -95 S. Archuleta Clerk - BUILDING PERMIT APPLICATION • OARFIELO COUNTY, COLORADO Applicant to complete nu /7 mberedssp a aces only. PERMIT NO. S PA NO. .ba AnoaESs d } 9 / OC 9 / v'- O (I Z. ' `- ��✓4"r �6LaiC 1 LEGAL LOT NO. BLOCK I SUBDMSION DESCR. 2 OWNER ASpen Glen Club ADDRESS PH. WK. PH. 3 CONTRACTOR Gould & Sons ADDRESS PEI. LICENSE NO. 4 ARCHITECT OR DESIGNER SG4 Inc. ADDRESS PH. LICENSE NO. 70797 5 ENGINEER S(7.1 Inc ADDRESS PH. LICENSE NO. 20797 6 SF OF BUILDING 544 7 .757// tlPrP N/A OF LOT N� ER X11 nt HEIGHT l3' NO. OF FLOORS 1 7 USE OF BUILDING notak13e' Water System Control 8 CLASS OF Watt e&NEW °ADDITION °ALTERATION 0REPAIR oMOVE aREMOVE 9 D ESCNE E YA] c Masonry Building that will house pumps. that pump notable water up to storage tank, and chlorination equipment that will disinfect water. 10 GARAGE SINGLE DOUBLE CARPORT SINGLE DOUBLE DRIVEWAY PERMIT ON SITE - SEWAGE DISPOSAL PERMIT SITE PLAN /7 �[` G 11 VAruMronoFNOacs 200,000 ADJUSTED.VALS OK PUWCHEa( ( / ' G /,J• ^ // PERMIT FEE+' O ?.3 SPECIAL CONDITIONS SCHOOL IMPACT FEE/ NO. OF BUILDINGS ON USE OF BUILDINGS NOW ON 5y / /�J^7 fJ PARCEL 8 /] PARCEL TOTAL F'EE((p J G. C , OGC. GR. (.J - /L- CONST. TYPE /" JJJ e- NOTICE WATER SUPPLY DATE PERMIT ISSUED 9 — - 9 J SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. Snnclu Maaovus REQLREO RECErvto Nor RECUREO THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS ZONING NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRICTION OR WORK I5 SUSPENDED OR ABANDONED FOR A PERIOD OF 180 OATS AT ANY TIME AFTER WORK IS COMMENCED. HEALTH DEPT. I HEREBY CERTIFY THAT I HAVE READ AND.EIAMINED THIS APPLICATION AND KNOW I THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES FIRE DEPT. I/ GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GNE SOIL REPORT AUTHORITY TO VIOLATE _OR CANCEL THE. PROVISIONS. OF ANY OTHER - STATE_ OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF SETBACKS CONSTRUCTION. ,p /lit'------ - i •••' 4994#/ FLOOD HPZARD Signature • e -. Contractor or autlredzed agent haying read and understood notice above_ 1 ...7aL ��._ _ I . / 7 - - MANUF. HOME - Building a :.. rbnent Approve/dal- II l 7'Planning Department Approval/date OTHER AGREEMENT - PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND /OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 3028.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS. SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS. SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT. DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THE AGREEMENT ABOVE (INITIAL/J/ 1 P '9(.. '5U /7 t' -Z V -9s GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for CONSTRUCTION OF COMMERCIAL OR MULTI - FAMILY RESIDENTIAL BUILDINGS including NEW CONSTRUCTION ADDITIONS ALTERATIONS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled "Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. 1 tJ G" „ r � f1 ( d9)—;q4 S -Pt ar wr -"VI" . - fLe ire • .:" Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes xx No u) Not necessary for this project (2) See final plat drawiggs on file in County 2. Are the plans submitted for application construction drawings and not drawings that are stamped or marked identifying them as "Not for construction, for permit issuance only ", "Approval drawings only ", "For permit issuance only" or similar language? Yes No _(1) Not necessary for this project (2) 3. Does the site plan include the location, including the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses of the I.S.D.S. (Individual Sewage Disposal System) and has the system been designed, stamped and signed by a Colorado registered engineer? Yes )« No (u Not necessary for this project (2) See final plat drawings on file in County 4. Does the site plan indicate the location and direction of the State, County or private road accessing the property? Yes 32( No (() Not necessary for this project (2) See final plat drawings on file in County 5. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes xx No (I) Not necessary for this project 6. If the building is a pre- engineered structure, is there a stamped, signed engineered foundation plan for this building? Yes No (n Not necessary for this project roc (2) 7. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes No (n Not necessary for this project (2) 8. Do the plans indicate the size an location of ventilation openings for the attic, roof joist spaces and soffits? Yes � No (1) Not necessary for this project (2) 2 F- n 9. Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per square foot in Garfield County)? Yes xx No (() Not necessary for this project (2) 10. Do the plans include design Loads as required for floor loads under Uniform Building Code Section 2304 and Tables 23 -A and 23 -B? Yes 30 ( No (() Not necessary for this project a) 11. Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes � No (,) Not necessary for this project (2) 12. Is the wind speed and exposure design included in the plan? Yes _'°` No (u Not necessary for this project _ 13. Does the building section thawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes _sac__ No u) Not necessary for this project (2) 14. Does the building section drawing or other detail include the method of positive connection of all columns and beams? Yes No (1) Not necessary for this project (2) 15. Does the plan indicate the height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes '' _ No ()) Not necessary for this project (2) 16. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase Ii EPA certification? Yes No u Not necessary for this project (2) 17. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes No o) Not necessary for this project (2) 18. Does the plan include a window schedule or other verification that egress /rescue windows from sleeping rooms and /or basements comply with the requirements of the Uniform Building Code? Yes No (() Not necessary for this project _xx__(2) 19. Does the plan include a window schedule or other verification that 3 windows. provide natural light and ventilation for all habitable rooms? Yes No (u Not necessary for this project XX (2) 20. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes No ()) Not necessary for this project (2) 21. Do the plans include a complete design for all mechanical systems planned for installation in this building? Yes No (I) Not necessary for this project (2) 22. Have all areas in the building been accurately identified for the intended use? (Occupancy as identified in the Uniform Building Code Table 5 -A) Yes ___ No u) Not necessary for this project 23. Does the plan indicate the quantity, form, use and storage of any hazardous materials that may be in use in this building? Yes XX No (I) Not necessary for this project (2) 24. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated on the plan? Yes No (l) Not necessary for this project )c (2) 25. Do the plans indicate the location and dimension of restroom facilities and if more that four employees and both sexes are employed, facilities for both sexes? Yes No u) Not necessary for this project ?__w 26. Do the plans indicate that restrooms and access to the building are handicapped accessible? Yes xx No (() Not necessary for this project (2) 27. Have two (2) complete sets of constructions drawings been submitted with the application? Yes No w Not necessary for this project (2) 28. Have you designed or had this plan designed while considering building and other construction code requirements? Yes xx No (3) 29. Does the plan accurately indicate what you intend to construct and 4 what will receive a final inspection by the Garfield County Building Department? Yes xx No (3) 30. Do you understand that approval for design and /or construction changes are required prior to the implementation of these changes? Yes _.x_ No (3) 31. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "Septic system " fees required, at the time you pick up your building permit? Yes xx No (3) 32. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and occupancy of the building? Yes _ _ No (3) 33. Are you aware that the person signing the Permit Application whether the "Owner ", "Agent of the Owner ", "General Contractor ", "Contractor" or otherwise, signing the application is the party responsible for the project complying with the Uniform Codes ". Yes xx No (3) I hereby acknowledge that I have read, understand and answered these questions accurately to the best of my ability. /-mac 9d* / /77 s' ature date Phone: ` JAS /c269-1 (days); Y�9 SAO (evenings) Project Name: ,lsi- Project Address: .t /,Uags /rdo , /. - 6athri (Refer to notes on next page) 5 Notes: (1) If you have answered "No" on any of these questions you may be required to provide this information at the request of the Building Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed without the issuance of the permit. (2) If you have answered "Not necessary for this project" on any of the questions and it is determined by the Building Official that the information is necessary to review the application and plans to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits in the review process and not reviewed until required information has been provided and the application rotates again to first position for review. B. Delay in issuance of the permit. C. Delay in proceeding with construction. (3) If you answered "No" to this question the circumstances described in the question could result in a "Stop Work Order" being issued or a "Certificate of Occupancy" not being issued. PerApp01.94 Effective - January 1, 1995 6 - -� - _ ENGINEERS SURVEYORS 070) 945 -1004 SCHMUESER 118 West 6th, Suite 200 FAX (970) 945 -5948 GORDON MEYER _ Glenwood Springs, CO 81601 July 31 , 1995 Mr. Art Hoagland, Building Official Garfield County Planning Department 109 Eighth Street, Room 301 Glenwood Springs, CO 81601 RE: Aspen Glen Well House Dear Art: Please find enclosed drawings and specifications for the Aspen Glen Well House. Water from potable water wells will be pumped to a below -grade clearwell. This water will be chlorinated and then pumped directly into the distribution system where it will fill a remote storage tank. The masonry constructed well house will contain high service pumps, motor control center panels and chlorination equipment. The location of the well, easements, etc., are shown within the Final Plat for Aspen Glen which is on file at the County Courthouse. if I can supply any additional information, please contact me. Sincerely, SCHMUESER GORDON MEYER, INC. Louis Meyer, P.E. LM:Ic/93028FO6.2 Enclosures: Application Form Plans and Specifications cc: Gary Lattie, Aspen Glen , .i .L ! 1 "E? Carbondale & Rural Fire Protection District l V � 300 Meadowood Dr. 1 riFi i ttG )UNITY Carbondale, Colorado 81623 Phone (970) 963 -2491 FAX (970) 963 -0569 September 19, 1995 Building Official Garfield County 109 8th Street, Suite 303 Glenwood Springs, CO 81601 Re: Aspen Glen Well House I have reviewed the plans for the Aspen Glen Well House for compliance with the 1994 Uniform Fire Code and would offer the following comments. • No identification signs were indicated for the entrances of the chlorine room and the storage room. Identification signs for these rooms are to be in accordance with UFC Section 8001.7. • The Fire District will work with the engineer and Aspen Glen in preparing a Hazardous Material Management Plan for the site. • Access and water supplies to the building for fire protection appear to be adequate. If you have any questions feel free to contact me at 963 -2491. Sincrejy, ; Bill Gavette, Fire Marshal Carbondale & Rural Fire Protection District • "- CC r Goo O 0 O ° 0 t = • y P+ N 0 a. • c4' ^ 0 d o Cr‘ _ u Q 0 V o H p— CO 1 A 'G O w N C 3. p "g g Q 0 C F p h U O u C . N , N ' O O ca v Z o 00 0 0 0 s A b .4.-• 5 3 a •C i v ++ 0. fl 3 e ++ o— O. ;b ° N ` '" oa u •� u 0 = O ^ ai 4 L. c) p u O L3 g .� m nn `` r.+ CC .. o a) r V t G o ° p ° un en o > Q ro rat tn 2 Q 00 or en o A Vj ,= O GP, a .' z 4.7 uj O o tot o • = U t V cn 0 •b o a WC U - U w O O ,� �i �� o, U �u c a CO L o v dEa CAS = V u 0 o � y y -511 Zs> ... ct O larso 0 3 m N U y V Lit ed - N O 0 �': ea 0 I S i e .~ U W ti x N TTT CO 7 c..)..._ t � - u 00 4-1 V • "Cl y� h O y "d .y it a) N U : 0 V �' • �r� b o ¢ al � w9r O ▪ h a 7 V .— U ^"y rya O l �,•) i O N �' Y p CD ' E � 1.) m r4 8 ' a .`� el Us 8 O m u t O P • En Q fr.., 4- es y 0 Cht �� N to C O V 0 u N c en o V 5 V la, C c o O • 3 u 'j E 'L7 s ` o �. Q`7 V O !a-1 U CQ )-,00